Influence of inner ear impedance on middle ear sound transfer functions

被引:0
作者
Zhai, Sijia [1 ]
Bornitz, Matthias [1 ]
Ssinger, Till Moritz E. [1 ]
Chen, Zhaoyu [1 ]
Neudert, Marcus [1 ]
机构
[1] Tech Univ Dresden, Fac Med Carl Gustav Carus, Ear Res Ctr Dresden ERCD, Dept Otorhinolaryngol Head & Neck Surg, Fetscherstr 74, D-01307 Dresden, Germany
关键词
Inner ear impedance; Middle ear transfer function; Footplate rotation; Round window stiffness; Cochleostomy; INPUT IMPEDANCE; TEMPORAL BONE; ROUND WINDOW; STAPES; DISPLACEMENT; PRESSURE; HEARING; MOTION;
D O I
10.1016/j.heliyon.2024.e27758
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Introduction: For experimental studies on sound transfer in the middle ear, it may be advantageous to perform the measurements without the inner ear. In this case, it is important to know the influence of inner ear impedance on the middle ear transfer function (METF). Previous studies provide contradictory results in this regard. With the current study, we investigate the influence of inner ear impedance in more detail and find possible reasons for deviations in the previous studies. Methods: 11 fresh frozen temporal bones were prepared in our study. The factors related to inner ear impedance, including round window membrane stiffness, cochleostomy, cochlea fluid and cochlea destruction were involved in the experimental design. After measuring in the intact specimen as a reference (step 1), the round window membrane was punctured (step 2), then completely removed (step 3). The cochleostomy was performed (step 4) before the cochlear fluid was carefully suctioned through scala tympani (step 5) and scala vestibuli (step 6). Finally, cochlea was destroyed by drilling (step 7). Translational and rotational movement of the stapes footplate were measured and calculated at each step. The results of the steps were compared to quantify the effect of inner ear impedance changing related to the process of cochlear drainage. Results: As the inner ear impedance decreases from step 1 to 7, the amplitudes of the METF curves at each frequency gradually increase in general. From step 6 on, the measured METF are significantly different with respect to the intact group at high frequencies above 3 kHz. The differences are frequency dependent. However, the significant decrement of rotational motion appears at the frequencies above 4.5 kHz from the step 5. Conclusion: This study confirms the influence of inner ear impedance on METF only at higher frequencies ( >= 3 kHz). The rotational motions are more sensitive to the drainage of fluid at the higher frequency. Study results that found no influence of cochlea impedance may be due to incomplete drainage of the cochlea.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] The impact of round window reinforcement on middle and inner ear mechanics with air and bone conduction stimulation
    Geerardyn, Alexander
    Wils, Irina
    Putzeys, Tristan
    Fierens, Guy
    Wouters, Jan
    Ab, Nicolas Verhaert
    HEARING RESEARCH, 2024, 450
  • [22] Middle ear structure and transcanal approach appropriate for middle ear surgery in rabbits
    Guan, Ming
    Zhang, Jie
    Jia, Yuezhi
    Cao, Xiaolin
    Lou, Xiangyu
    Li, Yong
    Gao, Xia
    EXPERIMENTAL AND THERAPEUTIC MEDICINE, 2019, 17 (02) : 1248 - 1255
  • [23] Effects of tympanic membrane perforation on middle ear transmission in gerbil
    Stomackin, Glenna
    Kidd, Stephanie
    Jung, Timothy T.
    Martin, Glen K.
    Dong, Wei
    HEARING RESEARCH, 2019, 373 : 48 - 58
  • [24] External and middle ear sound pressure distribution and acoustic coupling to the tympanic membrane
    Bergevin, Christopher
    Olson, Elizabeth S.
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2014, 135 (03) : 1294 - 1312
  • [25] Influence of the cochlear partition's flexibility on the macro mechanisms in the inner ear
    Kersten, Simon
    Taschke, Henning
    Vorlaender, Michael
    HEARING RESEARCH, 2024, 453
  • [26] Middle ear impedance measurements in large vestibular aqueduct syndrome
    Bilgen, Cem
    Kirkim, Guenay
    Kirazli, Tayfun
    AURIS NASUS LARYNX, 2009, 36 (03) : 263 - 268
  • [27] A New Method to Estimate Sound Energy Entering the Middle Ear
    Chen, Shixiong
    Deng, Jun
    Bian, Lin
    Li, Guanglin
    2013 35TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2013, : 29 - 32
  • [28] Active middle ear implants
    Lassaletta, Luis
    Sanchez-Cuadrado, Isabel
    Manuel Espinosa, Juan
    Batuecas, Angel
    Cenjor, Carlos
    Jose Lavilla, Maria
    Cavalle, Laura
    Huarte, Alicia
    Nunez, Faustino
    Manrique, Manuel
    Ramos, Angel
    de Paula, Carlos
    Gil-Carcedo, Elisa
    ACTA OTORRINOLARINGOLOGICA ESPANOLA, 2019, 70 (02): : 112 - 118
  • [29] Does systemic steroid deficiency affect inner ear functions?
    Dogan, Remzi
    Meric, Aysenur
    Gedik, Ozge
    Tugrul, Selahattin
    Eren, Sabri Baki
    Ozturan, Orhan
    AMERICAN JOURNAL OF OTOLARYNGOLOGY, 2015, 36 (04) : 568 - 574
  • [30] Inner ear labyrinth anatomy of monotremes and implications for mammalian inner ear evolution
    Schultz, Julia A.
    Zeller, Ulrich
    Luo, Zhe-Xi
    JOURNAL OF MORPHOLOGY, 2017, 278 (02) : 236 - 263