A comparison of the relative biological effectiveness of low energy electronic brachytherapy sources in breast tissue: a Monte Carlo study

被引:21
作者
White, Shane A. [1 ]
Reniers, Brigitte [1 ]
de Jong, Evelyn E. C. [1 ]
Rusch, Thomas [2 ]
Verhaegen, Frank [1 ,3 ]
机构
[1] Maastricht Univ, Med Ctr, Dept Radiat Oncol MAASTRO, GROW Sch Oncol & Dev Biol, NL-6200 MD Maastricht, Netherlands
[2] Xoft, San Jose, CA USA
[3] McGill Univ, Dept Oncol, Med Phys Unit, Montreal, PQ H3G 1A4, Canada
关键词
relative biological effectiveness; low energy brachytherapy; electronic brachytherapy; Monte Carlo; INTRAOPERATIVE RADIOTHERAPY TARGIT; CLUSTERED DNA LESIONS; X-RAYS; DAMAGE; RBE; IRRADIATION; SIMULATION; INDUCTION; DOSIMETRY; OXYGEN;
D O I
10.1088/0031-9155/61/1/383
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Electronic brachytherapy sources use low energy photons to treat the tumor bed during or after breast-conserving surgery. The relative biological effectiveness of two electronic brachytherapy sources was explored to determine if spectral differences due to source design influenced radiation quality and if radiation quality decreased with distance in the breast. The RBE was calculated through the number of DNA double strand breaks (RBEDSB) using the Monte Carlo damage simulator (MCDS) in combination with other Monte Carlo electron/photon spectrum calculations. 50kVp photons from the Intrabeam (Carl Zeiss Surgical) and Axxent (Xoft) through 40-mm spherical applicators were simulated to account for applicator and tissue attenuation in a variety of breast tissue compositions. 40kVp Axxent photons were also simulated. Secondary electrons (known to be responsible for most DNA damage) spectra at different distance were inputted into MCDS to calculate the RBEDSB. All RBEDSB used a cobalt-60 reference. RBEDSB data was combined with corresponding average photon spectrum energy for the Axxent and applied to model-based average photon energy distributions to produce an RBEDSB map of an accelerated partial breast irradiation (APBI) patient. Both Axxent and Intrabeam 50kVp spectra were shown to have a comparable RBEDSB of between 1.4 and 1.6 at all distances in spite of progressive beam hardening. The Axxent 40kVp also demonstrated a similar RBEDSB at distances. Most RBEDSB variability was dependent on the tissue type as was seen in rib (RBEDSB approximate to 1.4), gland (approximate to 1.55), adipose (approximate to 1.59), skin (approximate to 1.52) and lung (approximate to 1.50). RBEDSB variability between both sources was within 2%. A correlation was shown between RBEDSB and average photon energy and used to produce an RBEDSB map of a dose distribution in an APBI patient dataset. Radiation quality is very similar between electronic brachytherapy sources studied. No significant reductions in RBEDSB were observed with increasing distance from the source.
引用
收藏
页码:383 / 399
页数:17
相关论文
共 50 条
  • [21] Simulation study on potential accuracy gains from dual energy CT tissue segmentation for low-energy brachytherapy Monte Carlo dose calculations
    Landry, Guillaume
    Granton, Patrick V.
    Reniers, Brigitte
    Ollers, Michel C.
    Beaulieu, Luc
    Wildberger, Joachim E.
    Verhaegen, Frank
    PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (19) : 6257 - 6278
  • [22] Dosimetric parameters for three low-energy brachytherapy sources using the Monte Carlo N-Particle code
    DeMarco, JJ
    Hugo, G
    Solberg, TD
    MEDICAL PHYSICS, 2002, 29 (05) : 662 - 668
  • [23] Monte Carlo simulations of the relative biological effectiveness for DNA double strand breaks from 300 MeV u-1 carbon-ion beams
    Huang, Y. W.
    Pan, C. Y.
    Hsiao, Y. Y.
    Chao, T. C.
    Lee, C. C.
    Tung, C. J.
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (15) : 5995 - 6012
  • [24] Calculation of the DNA damage yield and relative biological effectiveness in boron neutron capture therapy via the Monte Carlo track structure simulation
    Han, Yang
    Geng, Changran
    Liu, Yuanhao
    Wu, Renyao
    Li, Mingzhu
    Yu, Chenxi
    Altieri, Saverio
    Tang, Xiaobin
    PHYSICS IN MEDICINE AND BIOLOGY, 2023, 68 (17)
  • [25] Dose measurements nearby low energy electronic brachytherapy sources using radiochromic film
    Devic, Slobodan
    Liang, LiHeng
    Tomic, Nada
    Bekerat, Hamed
    Morcos, Marc
    Popovic, Marija
    Watson, Peter
    Aldelaijan, Saad
    Seuntjens, Jan
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2019, 64 : 40 - 44
  • [26] Influences of spherical phantom heterogeneities on dosimetric charactristics of miniature electronic brachytherapy X-ray sources: Monte Carlo study
    Jashni, Hojatollah Karimi
    Safigholi, Habib
    Meigooni, Ali S.
    APPLIED RADIATION AND ISOTOPES, 2015, 95 : 108 - 113
  • [27] New National Air-Kerma Standard for Low-Energy Electronic Brachytherapy Sources
    Seltzer, Stephen M.
    O'Brien, Michelle
    Mitch, Michael G.
    JOURNAL OF RESEARCH OF THE NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY, 2014, 119 : 554 - 574
  • [28] Improved tissue assignment using dual-energy computed tomography in low-dose rate prostate brachytherapy for Monte Carlo dose calculation
    Cote, Nicolas
    Bedwani, Stephane
    Carrier, Jean-Franois
    MEDICAL PHYSICS, 2016, 43 (05) : 2611 - 2618
  • [29] Monte Carlo study of LDR seed dosimetry with an application in a clinical brachytherapy breast implant
    Furstoss, C.
    Reniers, B.
    Bertrand, M. J.
    Poon, E.
    Carrier, J. -F.
    Keller, B. M.
    Pignol, J. P.
    Beaulieu, L.
    Verhaegen, F.
    MEDICAL PHYSICS, 2009, 36 (05) : 1848 - 1858
  • [30] Dosimetric and radiobiological comparison of TG-43 and Monte Carlo calculations in 192Ir breast brachytherapy applications
    Peppa, V.
    Pappas, E. P.
    Karaiskos, P.
    Major, T.
    Polgar, C.
    Papagiannis, P.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2016, 32 (10): : 1245 - 1251