Size of Self-Expandable Transcatheter Heart Valve and Mid-Term Adverse Events After Transcatheter Aortic Valve Replacement

被引:0
作者
Hioki, Hirofumi [1 ,14 ,15 ]
Yamamoto, Masanori [2 ,3 ,4 ]
Watanabe, Yusuke [5 ]
Ohno, Yohei
Yashima, Fumiaki [6 ]
Naganuma, Toru [7 ,16 ]
Tada, Norio [8 ]
Shirai, Shinichi [9 ]
Yamanaka, Futoshi
Mizutani, Kazuki
Otsuka, Toshiaki [17 ]
Noguchi, Masahiko
Izumo, Masaki [11 ]
Takagi, Kensuke [10 ,18 ]
Asami, Masahiko [12 ,13 ]
机构
[1] IMS Tokyo Katsushika Gen Hosp, Dept Gastroenterol, Tokyo, Japan
[2] Toyohashi Heart Ctr, Dept Cardiol, Toyohashi, Japan
[3] Nagoya Heart Ctr, Dept Cardiol, Nagoya, Japan
[4] Gifu Heart Ctr, Dept Cardiol, Gifu, Japan
[5] Teikyo Univ Hosp, Dept Cardiol, Tokyo, Japan
[6] Saiseikai Utsunomiya Hosp, Dept Cardiol, Utsunomiya, Tochigi, Japan
[7] New Tokyo Hosp, Dept Cardiol, Matsudo, Japan
[8] Sendai Kosei Hosp, Dept Cardiol, Sendai, Japan
[9] Kokura Mem Hosp, Dept Cardiol, Kokura, Japan
[10] Kinki Univ, Dept Cardiol, Osaka, Japan
[11] St Marianna Univ, Dept Cardiol, Tokyo, Japan
[12] Natl Cerebral & Cardiovasc Ctr, Dept Cardiol, Osaka, Japan
[13] Mitsui Mem Hosp, Div Cardiol, Tokyo, Japan
[14] Toyama Univ Hosp, Dept Cardiol, Toyama, Japan
[15] Tsukuba Med Ctr Hosp, Dept Cardiol, Tsukuba, Japan
[16] Nippon Med Sch, Dept Hyg & Publ Hlth, Tokyo, Japan
[17] Nippon Med Sch, Ctr Clin Res, Tokyo, Japan
[18] Keio Univ, Sch Med, Div Cardiol, Tokyo, Japan
关键词
aortic stenosis; prognosis; self -expandable valve; TAVR; PROSTHESIS-PATIENT MISMATCH; CLINICAL-OUTCOMES; IMPLANTATION; REGURGITATION; HEMODYNAMICS; ASSOCIATION; STENOSIS; FAILURE; IMPACT;
D O I
10.1016/j.amjcard.2024.05.018
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The hemodynamic performance of self-expandable valves (SEVs) is a preferable choice for small aortic annuli in transcatheter aortic valve replacement (TAVR). However, no data are, so far, available regarding the relation between the size of SEVs and clinical outcomes. This study aimed to evaluate the impact of prosthesis size on adverse events after TAVR using SEVs. We retrospectively analyzed 1,400 patients (23-mm SEV: 13.6%) who underwent TAVR using SEVs at 12 centers. The impact of SEV size on all-cause death and heart failure (HF) after TAVR was evaluated by multivariate Cox regression and propensity score (PS) matching analysis. During the follow-up period (median 511 days), 201 all-cause deaths and 87 HF rehospitalizations were observed. The incidence of all-cause death was comparable between small- (23-mm SEV) and larger-sized (26- or 29-mm SEV) (16.8% vs 13.9%, log-rank p = 0.29). The size of SEV was not associated with a higher incidence of all-cause death (hazard ratio [HR] 1.21, 95% confidence interval [CI] 0.79 to 1.86 in Cox regression; HR 1.31, 95% CI 0.77 to 2.23 in PS matching) and HF after TAVR (subdistribution HR 0.79, 95% CI 0.37 to 1.72 in Cox regression; subdistribution HR 1.00, 95% CI 0.44 to 2.30 in PS matching). The multivariate model including postprocedural prosthesis-patient mismatch showed consistent results. In conclusion, small SEVs had comparable midterm clinical outcomes to larger-sized SEVs, even if the prosthesis-patient mismatch was observed after TAVR. (c) 2024 Elsevier Inc. All rights are reserved, including those for text and data mining, AI training, and similar technologies.
引用
收藏
页码:156 / 164
页数:9
相关论文
共 50 条
  • [41] Prosthesis valve dislocation and acute ascending aortic dissection during transcatheter self-expandable aortic valve replacement
    Yamashiro, Satoshi
    Kise, Yuya
    Inafuku, Hitoshi
    Nagano, Takaaki
    Kuniyoshi, Yukio
    CHIRURGIA-ITALY, 2021, 34 (01): : 41 - 43
  • [42] Temporal trends of frame expansion and paravalvular leak reduction after transcatheter aortic valve replacement with self-expandable prostheses
    Russo, Giulio
    Zambrano, Aniello
    Burzotta, Francesco
    Pedicino, Daniela
    Graziani, Francesca
    Cangemi, Stefano
    Bianchini, Francesco
    Bruno, Piergiorgio
    Locorotondo, Gabriella
    Calabrese, Michele
    Aurigemma, Cristina
    Romagnoli, Enrico
    MINERVA CARDIOLOGY AND ANGIOLOGY, 2023, : 172 - 181
  • [43] Transapical transcatheter aortic valve implantation for predominant aortic regurgitation with a self-expandable valve
    Liu, Huan
    Liu, Shun
    Lu, Yuntao
    Yang, Ye
    Wang, Wenshuo
    Zhu, Liming
    Wei, Lai
    Wang, Chunsheng
    JOURNAL OF THORACIC DISEASE, 2020, 12 (03) : 538 - 549
  • [44] Impact of balloon aortic valvuloplasty on transcatheter aortic valve implantation with self-expandable valve
    Vavuranakis, Manolis
    Lavda, Maria
    Vrachatis, Dimitrios
    Papaioannou, Theodore G.
    Kalogeras, Konstantinos
    Kolokathis, Angelos-Michail
    Kariori, Maria
    Lilly, Scott
    Siasos, Gerasimos
    Oikonomou, Evangelos
    Toutouzas, Konstantinos
    Stasinopoulou, Myrsini
    Deliveliotis, Konstantinos
    Tousoulis, Dimitrios
    JOURNAL OF CARDIOLOGY, 2017, 69 (1-2) : 245 - 252
  • [45] Hemodynamic and Mid-Term Outcomes for Transcatheter Aortic Valve Replacement in Degenerated Internally Stented Valves
    AlBadri, Ahmed
    Joseph, Jubin
    Patel, Vivek
    Patel, Dhairya
    Koren, Ofir
    Cheng, Wen
    Jilaihawi, Hasan
    Makkar, Raj
    JACC-CARDIOVASCULAR INTERVENTIONS, 2023, 16 (05) : 542 - 554
  • [46] Cusp overlap technique decreases paravalvular leakage in self-expandable transcatheter aortic valve replacement
    Takaseya, Tohru
    Itaya, Naoki
    Sasaki, Ken-ichiro
    Sasaki, Masahiro
    Yokomizo, Michiko
    Honda, Akihiro
    Oshita, Kensuke
    Azuma, Junpei
    Fukumoto, Yoshihiro
    Tayama, Eiki
    HEART AND VESSELS, 2024, 39 (01) : 48 - 56
  • [47] Self-expandable transcatheter valve is a potentially useful option for a failing small surgical aortic bioprosthetic valve
    Morita, Shohei
    Hiraoka, Arudo
    Chikazawa, Genta
    Takahashi, Shinya
    Sakaguchi, Taichi
    Yoshitaka, Hidenori
    GENERAL THORACIC AND CARDIOVASCULAR SURGERY, 2025, 73 (01) : 31 - 38
  • [48] Transcatheter Self-Expandable Aortic Valve Implantation After Undersized Mitral Annuloplasty
    Bruschi, Giuseppe
    De Marco, Federico
    Oreglia, Jacopo
    Colombo, Paola
    Barosi, Alberto
    Einaudi, Arturo
    Paino, Roberto
    Martinelli, Luigi
    Klugmann, Silvio
    ANNALS OF THORACIC SURGERY, 2011, 92 (05) : 1881 - 1883
  • [49] Outcomes After Transcatheter Aortic Valve Replacement With Balloon-Expandable Versus Self-Expandable Valves CHOICE Trial Results
    Montone, Rocco A.
    Testa, Luca
    Bedogni, Francesco
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2016, 67 (02) : 235 - 236
  • [50] Clinical and structural outcomes of neocommissural alignment in transaxillary and transcarotid transcatheter aortic valve implantation with a self-expandable transcatheter heart valve
    Mosquera, Victor X.
    Muinelo-Paul, Adrian
    Pato-Lopez, Oscar
    Bouzas-Mosquera, Alberto
    Cuenca-Castillo, Jose J.
    JTCVS TECHNIQUES, 2023, 22 : 150 - 158