Size of Self-Expandable Transcatheter Heart Valve and Mid-Term Adverse Events After Transcatheter Aortic Valve Replacement

被引:0
作者
Hioki, Hirofumi [1 ,14 ,15 ]
Yamamoto, Masanori [2 ,3 ,4 ]
Watanabe, Yusuke [5 ]
Ohno, Yohei
Yashima, Fumiaki [6 ]
Naganuma, Toru [7 ,16 ]
Tada, Norio [8 ]
Shirai, Shinichi [9 ]
Yamanaka, Futoshi
Mizutani, Kazuki
Otsuka, Toshiaki [17 ]
Noguchi, Masahiko
Izumo, Masaki [11 ]
Takagi, Kensuke [10 ,18 ]
Asami, Masahiko [12 ,13 ]
机构
[1] IMS Tokyo Katsushika Gen Hosp, Dept Gastroenterol, Tokyo, Japan
[2] Toyohashi Heart Ctr, Dept Cardiol, Toyohashi, Japan
[3] Nagoya Heart Ctr, Dept Cardiol, Nagoya, Japan
[4] Gifu Heart Ctr, Dept Cardiol, Gifu, Japan
[5] Teikyo Univ Hosp, Dept Cardiol, Tokyo, Japan
[6] Saiseikai Utsunomiya Hosp, Dept Cardiol, Utsunomiya, Tochigi, Japan
[7] New Tokyo Hosp, Dept Cardiol, Matsudo, Japan
[8] Sendai Kosei Hosp, Dept Cardiol, Sendai, Japan
[9] Kokura Mem Hosp, Dept Cardiol, Kokura, Japan
[10] Kinki Univ, Dept Cardiol, Osaka, Japan
[11] St Marianna Univ, Dept Cardiol, Tokyo, Japan
[12] Natl Cerebral & Cardiovasc Ctr, Dept Cardiol, Osaka, Japan
[13] Mitsui Mem Hosp, Div Cardiol, Tokyo, Japan
[14] Toyama Univ Hosp, Dept Cardiol, Toyama, Japan
[15] Tsukuba Med Ctr Hosp, Dept Cardiol, Tsukuba, Japan
[16] Nippon Med Sch, Dept Hyg & Publ Hlth, Tokyo, Japan
[17] Nippon Med Sch, Ctr Clin Res, Tokyo, Japan
[18] Keio Univ, Sch Med, Div Cardiol, Tokyo, Japan
关键词
aortic stenosis; prognosis; self -expandable valve; TAVR; PROSTHESIS-PATIENT MISMATCH; CLINICAL-OUTCOMES; IMPLANTATION; REGURGITATION; HEMODYNAMICS; ASSOCIATION; STENOSIS; FAILURE; IMPACT;
D O I
10.1016/j.amjcard.2024.05.018
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The hemodynamic performance of self-expandable valves (SEVs) is a preferable choice for small aortic annuli in transcatheter aortic valve replacement (TAVR). However, no data are, so far, available regarding the relation between the size of SEVs and clinical outcomes. This study aimed to evaluate the impact of prosthesis size on adverse events after TAVR using SEVs. We retrospectively analyzed 1,400 patients (23-mm SEV: 13.6%) who underwent TAVR using SEVs at 12 centers. The impact of SEV size on all-cause death and heart failure (HF) after TAVR was evaluated by multivariate Cox regression and propensity score (PS) matching analysis. During the follow-up period (median 511 days), 201 all-cause deaths and 87 HF rehospitalizations were observed. The incidence of all-cause death was comparable between small- (23-mm SEV) and larger-sized (26- or 29-mm SEV) (16.8% vs 13.9%, log-rank p = 0.29). The size of SEV was not associated with a higher incidence of all-cause death (hazard ratio [HR] 1.21, 95% confidence interval [CI] 0.79 to 1.86 in Cox regression; HR 1.31, 95% CI 0.77 to 2.23 in PS matching) and HF after TAVR (subdistribution HR 0.79, 95% CI 0.37 to 1.72 in Cox regression; subdistribution HR 1.00, 95% CI 0.44 to 2.30 in PS matching). The multivariate model including postprocedural prosthesis-patient mismatch showed consistent results. In conclusion, small SEVs had comparable midterm clinical outcomes to larger-sized SEVs, even if the prosthesis-patient mismatch was observed after TAVR. (c) 2024 Elsevier Inc. All rights are reserved, including those for text and data mining, AI training, and similar technologies.
引用
收藏
页码:156 / 164
页数:9
相关论文
共 50 条
  • [31] Aortic Angulation Does Not Impact Outcomes in Self-Expandable or Balloon-Expandable Transcatheter Aortic Valve Replacement
    Elmously, Adham
    Gray, Katherine D.
    Truong, Quynh A.
    Burshtein, Aaron
    Wong, S. Chiu
    de Biasi, Andreas R.
    Worku, Berhane
    Salemi, Arash
    CARDIOLOGY, 2018, 140 (02) : 96 - 102
  • [32] Short- and mid-term results after transapical transcatheter aortic valve replacement in nonagenarians
    De Biasi, Andreas R.
    Wong, S. Chiu
    Minutello, Robert M.
    Voudris, Konstantinos
    Worku, Berhane
    Girardi, Leonard N.
    Salemi, Arash
    JOURNAL OF CARDIOVASCULAR SURGERY, 2017, 58 (01) : 99 - 104
  • [33] Impact of paravalvular regurgitation on the mid-term outcome after transcatheter and surgical aortic valve replacement
    Laakso, Teemu
    Laine, Mika
    Moriyama, Noriaki
    Dahlbacka, Sebastian
    Airaksinen, Juhani
    Virtanen, Marko
    Husso, Annastiina
    Tauriainen, Tuomas
    Niemela, Matti
    Makikallio, Timo
    Valtola, Antti
    Eskola, Markku
    Juvonen, Tatu
    Biancari, Fausto
    Raivio, Peter
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2020, 58 (06) : 1145 - 1152
  • [34] Valve Hemodynamics and Clinical Outcomes After Transcatheter Aortic Valve Replacement for a Small Aortic Annulus
    Kamioka, Norihiko
    Arita, Takeshi
    Hanyu, Michiya
    Hayashi, Masaomi
    Watanabe, Shun
    Miura, Shiro
    Isotani, Akihiro
    Arai, Yoshio
    Kakumoto, Shinichi
    Ando, Kenji
    Shirai, Shinichi
    INTERNATIONAL HEART JOURNAL, 2019, 60 (01) : 86 - 92
  • [35] 1-Year Outcomes After Transcatheter Aortic Valve Replacement With Balloon-Expandable Versus Self-Expandable Valves Results From the CHOICE Randomized Clinical Trial
    Abdel-Wahab, Mohamed
    Neumann, Franz-Josef
    Mehilli, Julinda
    Frerker, Christian
    Richardt, Doreen
    Landt, Martin
    Jose, John
    Toelg, Ralph
    Kuck, Karl-Heinz
    Massberg, Steffen
    Robinson, Derek R.
    El-Mawardy, Mohamed
    Richardt, Gert
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2015, 66 (07) : 791 - 800
  • [36] Paravalvular leak prediction after transcatheter aortic valve replacement with self-expandable prosthesis based on quantitative aortic calcification analysis
    Wiktorowicz, Agata
    Wit, Adrian
    Malinowski, Krzysztof Piotr
    Dziewierz, Artur
    Rzeszutko, Lukasz
    Dudek, Dariusz
    Kleczynski, Pawel
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2021, 11 (02) : 652 - 664
  • [37] Deformation of a balloon-expandable transcatheter heart valve during transcatheter aortic valve replacement
    Yashima, Fumiaki
    Sato, Masatoshi
    Yoshijima, Nobuhiro
    Nara, Tsutomu
    Kasai, Mio
    Hashizume, Kenichi
    CARDIOVASCULAR INTERVENTION AND THERAPEUTICS, 2025, 40 (01) : 199 - 200
  • [38] Redo-transcatheter aortic valve replacement with the supra-annular, self-expandable Evolut platform: Insights from the Transcatheter valve Therapy Registry
    Attizzani, Guilherme F.
    Dallan, Luis Augusto P.
    Forrest, John K.
    Reardon, Michael J.
    Szeto, Wilson Y.
    Liu, Fang
    Pelletier, Marc
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2022, 99 (03) : 869 - 876
  • [39] Mid-Term Valve-Related Outcomes After Transcatheter Tricuspid Valve-in-Valve or Valve-in-Ring Replacement
    McElhinney, Doff B.
    Aboulhosn, Jamil A.
    Dvir, Danny
    Whisenant, Brian
    Zhang, Yulin
    Eicken, Andreas
    Ribichini, Flavio
    Tzifa, Aphrodite
    Hainstock, Michael R.
    Martin, Mary H.
    Kornowski, Ran
    Schubert, Stephan
    Latib, Azeem
    Thomson, John D. R.
    Torres, Alejandro J.
    Meadows, Jeffery
    Delaney, Jeffrey W.
    Guerrero, Mayra E.
    Salizzoni, Stefano
    El-Said, Howaida
    Finkelstein, Ariel
    George, Isaac
    Gewillig, Marc
    Alvarez-Fuente, Maria
    Lamers, Luke
    Cheema, Asim N.
    Kreutzer, Jacqueline N.
    Rudolph, Tanja
    Hildick-Smith, David
    Cabalka, Allison K.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2019, 73 (02) : 148 - 157
  • [40] Short-term outcome after transcatheter aortic valve replacement with a novel balloon-expandable valve
    Halim, J.
    den Heijer, P.
    van den Branden, B.
    Meuwissen, M.
    Vos, J.
    Scholzel, B.
    IJsselmuiden, A.
    NETHERLANDS HEART JOURNAL, 2023, 31 (12) : 500 - 505