Size of Self-Expandable Transcatheter Heart Valve and Mid-Term Adverse Events After Transcatheter Aortic Valve Replacement

被引:0
作者
Hioki, Hirofumi [1 ,14 ,15 ]
Yamamoto, Masanori [2 ,3 ,4 ]
Watanabe, Yusuke [5 ]
Ohno, Yohei
Yashima, Fumiaki [6 ]
Naganuma, Toru [7 ,16 ]
Tada, Norio [8 ]
Shirai, Shinichi [9 ]
Yamanaka, Futoshi
Mizutani, Kazuki
Otsuka, Toshiaki [17 ]
Noguchi, Masahiko
Izumo, Masaki [11 ]
Takagi, Kensuke [10 ,18 ]
Asami, Masahiko [12 ,13 ]
机构
[1] IMS Tokyo Katsushika Gen Hosp, Dept Gastroenterol, Tokyo, Japan
[2] Toyohashi Heart Ctr, Dept Cardiol, Toyohashi, Japan
[3] Nagoya Heart Ctr, Dept Cardiol, Nagoya, Japan
[4] Gifu Heart Ctr, Dept Cardiol, Gifu, Japan
[5] Teikyo Univ Hosp, Dept Cardiol, Tokyo, Japan
[6] Saiseikai Utsunomiya Hosp, Dept Cardiol, Utsunomiya, Tochigi, Japan
[7] New Tokyo Hosp, Dept Cardiol, Matsudo, Japan
[8] Sendai Kosei Hosp, Dept Cardiol, Sendai, Japan
[9] Kokura Mem Hosp, Dept Cardiol, Kokura, Japan
[10] Kinki Univ, Dept Cardiol, Osaka, Japan
[11] St Marianna Univ, Dept Cardiol, Tokyo, Japan
[12] Natl Cerebral & Cardiovasc Ctr, Dept Cardiol, Osaka, Japan
[13] Mitsui Mem Hosp, Div Cardiol, Tokyo, Japan
[14] Toyama Univ Hosp, Dept Cardiol, Toyama, Japan
[15] Tsukuba Med Ctr Hosp, Dept Cardiol, Tsukuba, Japan
[16] Nippon Med Sch, Dept Hyg & Publ Hlth, Tokyo, Japan
[17] Nippon Med Sch, Ctr Clin Res, Tokyo, Japan
[18] Keio Univ, Sch Med, Div Cardiol, Tokyo, Japan
关键词
aortic stenosis; prognosis; self -expandable valve; TAVR; PROSTHESIS-PATIENT MISMATCH; CLINICAL-OUTCOMES; IMPLANTATION; REGURGITATION; HEMODYNAMICS; ASSOCIATION; STENOSIS; FAILURE; IMPACT;
D O I
10.1016/j.amjcard.2024.05.018
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The hemodynamic performance of self-expandable valves (SEVs) is a preferable choice for small aortic annuli in transcatheter aortic valve replacement (TAVR). However, no data are, so far, available regarding the relation between the size of SEVs and clinical outcomes. This study aimed to evaluate the impact of prosthesis size on adverse events after TAVR using SEVs. We retrospectively analyzed 1,400 patients (23-mm SEV: 13.6%) who underwent TAVR using SEVs at 12 centers. The impact of SEV size on all-cause death and heart failure (HF) after TAVR was evaluated by multivariate Cox regression and propensity score (PS) matching analysis. During the follow-up period (median 511 days), 201 all-cause deaths and 87 HF rehospitalizations were observed. The incidence of all-cause death was comparable between small- (23-mm SEV) and larger-sized (26- or 29-mm SEV) (16.8% vs 13.9%, log-rank p = 0.29). The size of SEV was not associated with a higher incidence of all-cause death (hazard ratio [HR] 1.21, 95% confidence interval [CI] 0.79 to 1.86 in Cox regression; HR 1.31, 95% CI 0.77 to 2.23 in PS matching) and HF after TAVR (subdistribution HR 0.79, 95% CI 0.37 to 1.72 in Cox regression; subdistribution HR 1.00, 95% CI 0.44 to 2.30 in PS matching). The multivariate model including postprocedural prosthesis-patient mismatch showed consistent results. In conclusion, small SEVs had comparable midterm clinical outcomes to larger-sized SEVs, even if the prosthesis-patient mismatch was observed after TAVR. (c) 2024 Elsevier Inc. All rights are reserved, including those for text and data mining, AI training, and similar technologies.
引用
收藏
页码:156 / 164
页数:9
相关论文
共 50 条
  • [1] Impact of Repositioning on Outcomes Following Transcatheter Aortic Valve Replacement With a Self-Expandable Valve
    Attizzani, Guilherme F.
    Dallan, Luis Augusto P.
    Markowitz, Alan
    Yakubov, Steven J.
    Deeb, G. Michael
    Reardon, Michael J.
    Forrest, John K.
    Mangi, Abeel A.
    Huang, Jian
    Popma, Jeffrey J.
    JACC-CARDIOVASCULAR INTERVENTIONS, 2020, 13 (15) : 1816 - 1824
  • [2] Aortic valve morphology and paravalvular leak regression after a self-expandable transcatheter aortic valve replacement
    Jin, Qinchun
    Li, Wei
    Chen, Shasha
    Li, Mingfei
    Zhou, Daxin
    Zhang, Xiaochun
    Ge, Junbo
    FRONTIERS IN PHYSIOLOGY, 2023, 13
  • [3] Use of Snare Catheter Technique in Transcatheter Aortic Valve Replacement With Self-Expandable Valve: Expert Review
    Aquino-Bruno, Heberto
    Garcia-Garcia, Juan F.
    Gayosso-Ortiz, Jose R.
    Alcantara-Melendez, Marco A.
    Fuentes-Moreno, Juan C.
    Blancas Perez, Luis A.
    Hernandez-Flores, Kevin R.
    Muratalla-Gonzalez, Roberto
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2025, : 981 - 989
  • [4] Comparison of Balloon-Expandable Valve and Self-Expandable Valve in Transcatheter Aortic Valve Replacement: A Patient-Specific Numerical Study
    Li, Jianming
    Yan, Wentao
    Wang, Wenshuo
    Wang, Shengzhang
    Wei, Lai
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2022, 144 (10):
  • [5] Anatomical Predictors of Valve Malposition During Self-Expandable Transcatheter Aortic Valve Replacement
    Li, Jie
    Sun, Yinghao
    Zheng, Shengneng
    Li, Guang
    Dong, Haojian
    Fu, Ming
    Mo, Yujing
    Li, Yi
    Liu, Huadong
    Xu, Zhaoyan
    Zhang, Liting
    Cao, Yong
    Fan, Ruixin
    Lim, D. Scott
    Luo, Jianfang
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2021, 8
  • [6] Echocardiographic Imaging of Procedural Complications During Self-Expandable Transcatheter Aortic Valve Replacement
    Hahn, Rebecca T.
    Gillam, Linda D.
    Little, Stephen H.
    JACC-CARDIOVASCULAR IMAGING, 2015, 8 (03) : 319 - 336
  • [7] Coronary obstruction occurring 72 h after transcatheter aortic valve replacement with a self-expandable valve
    Miyazaki, Yosuke
    Okamura, Takayuki
    Fujita, Akira
    Mikamo, Akihito
    Oda, Tetsuro
    Wada, Yasuaki
    Yamashita, Atsuo
    Suzuki, Ryo
    Takahashi, Masaya
    Hamano, Kimikazu
    Yano, Masafumi
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2016, 223 : 1 - 3
  • [8] The Results of Transcatheter Aortic Valve Replacement Continue to Improve The Specific Example of a Self-Expandable Transcatheter Heart Valve in a Real-Life Registry
    Vahanian, Alec
    Urena, Marina
    JACC-CARDIOVASCULAR INTERVENTIONS, 2017, 10 (20) : 2099 - 2100
  • [9] Aortic Angulation and Self-Expandable Transcatheter Aortic Valve Replacement Outcomes
    Abramowitz, Yigal
    JACC-CARDIOVASCULAR INTERVENTIONS, 2021, 14 (11) : 1216 - 1217
  • [10] Alcohol Septal Ablation for Worsening Heart Failure After Transcatheter Aortic Valve Replacement With Self-Expandable Valve
    Akita, Keitaro
    Suzuki, Yuichi
    Sato, Ryota
    Suwa, Kenichiro
    Iguchi, Keisuke
    Mogi, Satoshi
    Ohtani, Hayato
    Maekawa, Yuichiro
    JACC-CARDIOVASCULAR INTERVENTIONS, 2022, 15 (04) : 458 - 459