摘要
An innovative electrochemical redox response of hydroquinone (HQN) and catechol (CCL) was analysed using a bare graphite and graphene composite paste electrode (BGGCPE) and polymerised L-leucine modified graphite and graphene composite paste electrode (LCN-MGGCPE) was successfully developed in 0.2 M phosphate buffer solution (PBS) with pH 6.0 at a 0.1 V/s scan rate. Fabricated electrode using simple and cost-effective method, the polymerised LCN-MGGCPE surface shows more electrochemical activity, sensitivity and selectivity towards the determination for HQN and CCL. Cyclic voltammetry (CV), linear sweep voltammetry (LSV), Differential pulse voltammetry (DPV), and electrochemical impudence spectroscopy (EIS) were utilised as analytical techniques while LCN-MGGCPE and BGGCPE surface characterisation were studied using a scanning electron microscopy (SEM) technique. LCN-MGGCPE exhibited superior electrochemical activity compared to BGGCPE towards the oxidation responses of both HQN and CCL. Additionally, the effect of pH studies, scan rate change for HQN, and concentration change of analyte molecule were examined, with the 0.025 to 0.500 V/s scan rate varied and revealing an adsorption-controlled process. The concentration changes of CVs methods ranged from 0.2 to 320 mu M, DPVs ranged from 0.2 to 1100 mu M and LSVs ranged from 0.2 to 850 mu M, the calculated a limit of detection (LOD) of CV, DPV, and LSV, is 0.020 mu M, 0.026 mu M, and 0.011 mu M and a limit of quantification (LOQ) of 0.068 mu M, 0.088 mu M, and 0.035 mu M. The electrochemically developed LCN-MGGCPE shows good reproducibility, repeatability, stability, sensitivity and simultaneous analysis of analyte molecules were studied. This study presents a promising pathway for the growth of effective sensors for the determination of HQN in medicinal and water sample applications.
引用
收藏
页数:19
相关论文
共 53 条
[1]   Copper oxide and carbon nano-fragments modified glassy carbon electrode as selective electrochemical sensor for simultaneous determination of catechol and hydroquinone in real-life water samples [J].
Alshahrani, Lina Abdullah ;
Liu, Lingyu ;
Sathishkumar, Palanivel ;
Nan, Junmin ;
Gu, Feng Long .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2018, 815 :68-75
[3]   Electrochemical properties and simultaneous determination of dihydroxybenzene isomers at ordered mesoporous carbon-modified electrode [J].
Bai, Jing ;
Guo, Liping ;
Ndamanisha, Jean Chrysostome ;
Qi, Bin .
JOURNAL OF APPLIED ELECTROCHEMISTRY, 2009, 39 (12) :2497-2503
[4]  
Beitollahi H, 2019, INT J NANO DIMENS, V10, P125
[5]   Novel ruthenium doped TiO2/reduced graphene oxide hybrid as highly selective sensor for the determination of ambroxol [J].
Bukkitgar, Shikandar D. ;
Shetti, Nagaraj P. ;
Malladi, Ramesh S. ;
Reddy, Kakarla Raghava ;
Kalanur, Shankara S. ;
Aminabhavi, Tejraj M. .
JOURNAL OF MOLECULAR LIQUIDS, 2020, 300
[6]   Ultrathin CdSe nanosheets: Synthesis and application in simultaneous determination of catechol and hydroquinone [J].
Cao, Xia ;
Cai, Xiaolan ;
Feng, Quanchen ;
Jia, Shu ;
Wang, Ning .
ANALYTICA CHIMICA ACTA, 2012, 752 :101-105
[7]   Electrochemical sensing of adrenaline using surface modified carbon nanotube paste electrode [J].
Charithra, M. M. ;
Manjunatha, J. G. .
MATERIALS CHEMISTRY AND PHYSICS, 2021, 262
[8]   Determination of polyphenols by high-performance liquid chromatography with inhibited chemiluminescence detection [J].
Cui, H ;
He, CX ;
Zhao, GW .
JOURNAL OF CHROMATOGRAPHY A, 1999, 855 (01) :171-179
[9]  
D Souza O.J., 2019, Sci. China. Chem, V62, P262, DOI [10.1007/s11426-018-9353-x, DOI 10.1007/S11426-018-9353-X]
[10]   ENVIRONMENTAL AND HEALTH RISKS OF HYDROQUINONE [J].
DEVILLERS, J ;
BOULE, P ;
VASSEUR, P ;
PREVOT, P ;
STEIMAN, R ;
SEIGLEMURANDI, F ;
BENOITGUYOD, JL ;
NENDZA, M ;
GRIONI, C ;
DIVE, D ;
CHAMBON, P .
ECOTOXICOLOGY AND ENVIRONMENTAL SAFETY, 1990, 19 (03) :327-354