Theoretical study of a novel intermediate temperature photovoltaic/ thermal system equipped with heat pipe and evacuated tube

被引:2
|
作者
Ren, Xiao [1 ]
Dang, Gangqiang [1 ]
Gong, Liang [1 ]
Li, Jing [2 ]
Zhu, Chuanyong [1 ]
Duan, Xinyue [1 ]
Pei, Gang [3 ]
机构
[1] China Univ Petr East China, Coll New Energy, Qingdao, Peoples R China
[2] Univ Hull, Energy & Environm Inst, Res Ctr Sustainable Energy Technol, Kingston Upon Hull, England
[3] Univ Sci & Technol China, Dept Thermal Sci & Energy Engn, Hefei, Peoples R China
基金
中国国家自然科学基金; 中国博士后科学基金;
关键词
Evacuated tube; Photovoltaic/thermal system; Distributed parameter model; Intermediate temperature; Temperature uniformity; SOLAR; COLLECTORS; STRESS; PV/T; ENERGY;
D O I
10.1016/j.applthermaleng.2024.123207
中图分类号
O414.1 [热力学];
学科分类号
摘要
Solar photovoltaic/thermal (PV/T) technology has enormous promise in the field of renewable cogeneration as a key technology to increase the utilization rate of solar energy. The structural restrictions of PV/T and the high power temperature coefficient of solar cells make PV/T mostly used in low-temperature situations. However, the combination of intermediate temperature PV/T and low-grade energy utilization devices can create a wider range of application values, including absorption refrigeration, seawater desalination, and the organic Rankine cycle. To increase the overall efficiency and thermal energy grade of the PV/T system, a novel heat pipe evacuated tube PV/T (HE-PV/T) system is proposed. The heat transfer is modeled using distributed parameters, and the thermoelectric performance and temperature uniformity are computed through numerical simulation. The impacts of different parameters on the thermodynamic performance of the HE-PV/T system are examined. Compared with traditional flat plate PV/T, the system's overall energy utilization efficiency and exergy efficiency have been significantly increased. When the inlet temperature is 80.0 degrees C, the overall energy and exergy efficiency of the HE-PV/T system can reach 33.55 % and 7.92 %, which is 29.66 % and 21.97 % higher than that of flat plate PV/T. Besides, the temperature distribution of the HE-PV/T is more uniform, which is beneficial for reducing thermal stress and mechanical damage. The property superiority and thermodynamic feasibility of the HE-PV/T system at medium temperature are demonstrated.
引用
收藏
页数:21
相关论文
共 50 条
  • [41] EXPERIMENTAL INVESTIGATION OF ENERGY CHARACTERISTICS OF EVACUATED TUBE HEAT-PIPE SOLAR COLLECTOR SYSTEM
    Kavolynas, Antanas
    Drejeris, Rolandas
    7TH INTERNATIONAL SCIENTIFIC CONFERENCE RURAL DEVELOPMENT 2015: TOWARDS THE TRANSFER OF KNOWLEDGE, INNOVATIONS AND SOCIAL PROGRESS, 2015,
  • [42] A Review on the Heat Pipe Photovoltaic/Thermal (PV/T) System
    Zhou Jinzhi
    Zhong Wei
    Wu Dan
    Yuan Yanping
    Ji Wenhui
    He Wei
    JOURNAL OF THERMAL SCIENCE, 2021, 30 (05) : 1469 - 1490
  • [43] A new desalination system using a combination of heat pipe, evacuated tube and parabolic trough collector
    Mosleh, H. Jafari
    Mamouri, S. Jahangiri
    Shafii, M. B.
    Sima, A. Hakim
    ENERGY CONVERSION AND MANAGEMENT, 2015, 99 : 141 - 150
  • [44] Experimental studies of thermal performance of an evacuated tube heat pipe solar collector in Polish climatic conditions
    Siuta-Olcha, Alicja
    Cholewa, Tomasz
    Dopieralska-Howoruszko, Kinga
    ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2021, 28 (12) : 14319 - 14328
  • [45] Improving the performance of heat pipe embedded evacuated tube collector with nanofluids and auxiliary gas system
    Daghigh, Roonak
    Zandi, Pooya
    RENEWABLE ENERGY, 2019, 134 : 888 - 901
  • [46] Thermal performance of a heat-pipe evacuated-tube solar collector at high inlet temperatures
    Elsheniti, Mahmoud B.
    Kotb, Amr
    Elsamni, Osama
    APPLIED THERMAL ENGINEERING, 2019, 154 : 315 - 325
  • [47] Experimental studies of thermal performance of an evacuated tube heat pipe solar collector in Polish climatic conditions
    Alicja Siuta-Olcha
    Tomasz Cholewa
    Kinga Dopieralska-Howoruszko
    Environmental Science and Pollution Research, 2021, 28 : 14319 - 14328
  • [48] Experimental analysis of thermal performance according to heat pipe working fluids for evacuated tube solar collector
    Hong-Jin Joo
    Hee-Youl Kwak
    Heat and Mass Transfer, 2017, 53 : 3267 - 3275
  • [49] Experimental analysis of thermal performance according to heat pipe working fluids for evacuated tube solar collector
    Joo, Hong-Jin
    Kwak, Hee-Youl
    HEAT AND MASS TRANSFER, 2017, 53 (11) : 3267 - 3275
  • [50] Analysis of heat transfer characteristics for parabolic trough solar collector system with heat-pipe evacuated tube
    Zhang W.
    Wang J.
    Tian R.
    Xue Q.
    Ba X.
    2018, Chinese Society of Agricultural Engineering (34): : 202 - 209