Research on infrared spectroscopy detection of furfural content in transformer oil based on acetonitrile extraction

被引:0
|
作者
Tian, Yi [1 ,2 ]
Li, Zhiwei [1 ]
Wang, Shuai [1 ]
Zhu, Guixin [1 ]
Shi, Haonan [1 ]
Wang, Yanru [1 ]
Niu, Bo [3 ]
Zhu, Yongcan [1 ]
Huang, Xinbo [1 ]
机构
[1] Xian Polytech Univ, Xian Key Lab Interconnected Sensing & Intelligent, Xian 710048, Shaanxi, Peoples R China
[2] Xi An Jiao Tong Univ, State Key Lab Elect Insulat & Power Equipment, Xian 710049, Shaanxi, Peoples R China
[3] State Grid Ningxia Elect Power Co Ltd, Power Res Inst, Yinchuan 750001, Ningxia, Peoples R China
基金
中国博士后科学基金;
关键词
oil-paper insulation; infrared spectroscopy; furfural; acetonitrile extraction; AGING ASSESSMENT; INSULATION; PAPER; PREDICTION; MODEL;
D O I
10.1088/1361-6501/ad4bfe
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The stable operation of power transformers depends on the oil-paper insulation system, in which the aging degree of insulating paper is the key to evaluate the remaining life of the transformer. Currently, methanol extraction is widely used to detect the furfural content in oil to evaluate the aging state of insulating paper, but it ignores the influence of methanol produced during the operation of the transformer on the extraction results. To address this issue, this paper proposes a new method that can replace methanol extraction for detecting furfural in oil through simulation and experiment. Firstly, through simulation and experiment, it is proved that the strong vibration absorption peaks at 1677 cm-1 for furfural carbonyl and 2240 cm-1 for acetonitrile cyano can be used to establish a new method for extracting furfural content in oil using acetonitrile. A quantitative model between the concentration x of furfural in the furfural-acetonitrile mixed solution and the area y of the infrared absorption peak at 1677 cm-1 is established, with a goodness of fit of 0.9974. Secondly, a comparison between direct detection and acetonitrile extraction methods is conducted. The results show that direct detection is simple to operate, but the minimum detection concentration is 40 mg l-1, which is difficult to meet practical requirements. Acetonitrile extraction can reduce the minimum detection concentration to 0.1 mg l-1. At the same time, the extraction conditions are analyzed to determine the extraction ratio of 30, extraction times of 5, and extraction rate of 60%. Finally, the proposed detection method is applied to thermal aging tests on insulating paper of different types. The experimental results show that the proposed method has good repeatability and improves the detection resolution of furfural content. This paper combines infrared spectroscopy with acetonitrile extraction technology to open up a more efficient and practical new method for detecting furfural content in transformer oil.
引用
收藏
页数:16
相关论文
共 50 条
  • [31] The Effects of Furoic Acid and Furfuryl Alcohol on Detection of Furfural in Transformer Oil by High-Performance Liquid Chromatography
    Xiaobo Liu
    Ying Zhang
    Meijie Shang
    Liping Zhu
    Min Yu
    Chromatographia, 2020, 83 : 927 - 932
  • [32] Research on a New PD Detection Sensor in Transformer Oil Tank Seam
    Zhao, Yan
    Zheng, Shu-Sheng
    Yan, Xiao-Hu
    Kong, Ju
    Liu, Dong-Chen
    Zhong, Ai-Xu
    IEEE SENSORS JOURNAL, 2023, 23 (20) : 25460 - 25472
  • [33] The Effects of Furoic Acid and Furfuryl Alcohol on Detection of Furfural in Transformer Oil by High-Performance Liquid Chromatography
    Liu, Xiaobo
    Zhang, Ying
    Shang, Meijie
    Zhu, Liping
    Yu, Min
    CHROMATOGRAPHIA, 2020, 83 (08) : 927 - 932
  • [34] Predictive maintenance of railway transformer oil based on periodic content analysis
    Habeeb, Hiyam Adil
    Mohan, Ahmed Esmael
    Abdullah, Mohd Azman
    Othman, Megat Muhammad Haziq
    Dan, Reduan Mat
    Harun, Mohd Hanif
    JURNAL TRIBOLOGI, 2020, 27 : 71 - 101
  • [35] Moisture Content Online Detection in Fluidized Bed Drying Process Based on Near Infrared Spectroscopy and XGBoost
    He, Shuai
    Zhou, Jie
    Zhang, Fu-lin
    Mu, Guo-qing
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2024, 44 (12) : 3347 - 3352
  • [36] Research on Moisture Content Evaluation Algorithm of Transformer Oil-Paper Insulation System
    Zhang, Mingze
    Liu, Ji
    Qi, Pengshuai
    Chen, Qingguo
    Lv, Jialu
    Sun, Yufei
    Chen, Xin
    2018 IEEE INTERNATIONAL CONFERENCE ON HIGH VOLTAGE ENGINEERING AND APPLICATION (ICHVE), 2018,
  • [37] Monitoring of Low Levels of Furfural in Power Transformer Oil with a Sensor System Based on a POF-MIP Platform
    Cennamo, Nunzio
    De Maria, Letizia
    D'Agostino, Girolamo
    Zeni, Luigi
    Pesavento, Maria
    SENSORS, 2015, 15 (04): : 8499 - 8511
  • [38] Research on Determination of Nitrogen Content in Petroleum Using Mid-infrared Spectroscopy
    Li Jingyan
    Chu Xiaoli
    Tian Songbai
    Lu Wanzhen
    CHINA PETROLEUM PROCESSING & PETROCHEMICAL TECHNOLOGY, 2011, 13 (04) : 1 - 7
  • [39] The Research Progress in Determining Lignocellulosic Content by Near Infrared Reflectance Spectroscopy Technology
    Du Juan
    An Dong
    Xia Tian
    Huang Yan-hua
    Hong-chao, Li
    Zhang Yun-wei
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2013, 33 (12) : 3207 - 3211
  • [40] Online Detection of Soluble Solids Content in Different Parts of Watermelons Based on Full Transmission Near Infrared Spectroscopy
    Yan Zhong-Wei
    Tian Xi
    Zhang Yi-Fei
    Li Lian-Jie
    Liu San-Ging
    Huang Wen -Giat
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43 (06) : 1800 - 1808