INVESTIGATIONS OF HEAT TRANSFER AND FILM COOLING EFFECT ON A WORN SQUEALER TIP

被引:0
|
作者
Ye, Mingliang [1 ]
Yan, Xin [1 ]
机构
[1] Xi An Jiao Tong Univ, Inst Turbomachinery, Xian 710049, Peoples R China
来源
PROCEEDINGS OF THE ASME TURBO EXPO: TURBOMACHINERY TECHNICAL CONFERENCE AND EXPOSITION, VOL 7B, PT I | 2020年
关键词
squealer tip; wear; heat transfer; film cooling; BLADE TIP/SHROUD RUBS;
D O I
暂无
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Wear damage commonly occurs in modern gas turbine rotor blade tip due to relative movements and expansions between rotating and stationary parts. Tip wear has a significant impact on the aerodynamic, heat transfer and cooling performance of rotor blades, thus threatening the economy and safety of whole gas turbine system. Based on a simple linear wear model, this paper numerically investigates the aerodynamic, heat transfer and film cooling performance of a worn squealer tip with three starting-locations of wear (sl=25%C-ax, 50%C-ax and 75%C-ax) and five wear-depths (wd=0.82%, 1.64%, 2.46%, 3.28% and 4.10%). Firstly, based on the existing experimental data, numerical methods and grid independence are examined carefully. Then, three dimensional flow fields, total pressure loss distributions, heat transfer coefficients and film cooling effectiveness in worn squealer tip region are computed, which are compared with the original design case. The results show that, with the increase of wear depth and the movement of wear starting-location to the leading edge, the scale and intensity of cavity vortex are increased, which results in the extended high heat transfer area on cavity floor near the leading edge. Wear makes more coolant flow out of the cavity, and reduces the area-averaged film cooling effectiveness at the bottom of cavity, but increases the film cooling effectiveness on pressure-side rim. The increase of wear depth makes more flow leak through the tip gap, thus increasing the scale and intensity of leakage vortex and further increasing the total pressure loss in the tip gap. Compared with the original design case, as the wear depth is increased from 0.82% to 4.10%, the mass-averaged total pressure loss in cascade is increased by 0.3-6.7%, the area-averaged heat transfer coefficient on cavity floor is increased by 1.7-29.1% while on squealer rim it is decreased by 3.1-26.3%, and the area-averaged film cooling effectiveness on cavity floor is decreased by 0.035 at most while on squealer rim it is increased by 0.064 at most.
引用
收藏
页数:15
相关论文
共 50 条
  • [41] FILM COOLING AND AERODYNAMIC PERFORMANCE ON MULTI-CAVITY SQUEALER TIP OF A TURBINE BLADE
    Li, Feng
    Liu, Zhao
    Feng, Zhenping
    PROCEEDINGS OF ASME TURBO EXPO 2021: TURBOMACHINERY TECHNICAL CONFERENCE AND EXPOSITION, VOL 5A, 2021,
  • [42] Effect of wear damage on aero-thermal performance of the film-cooled squealer tip in a turbine stage
    Ye, Mingliang
    Yan, Xin
    He, Kun
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART A-JOURNAL OF POWER AND ENERGY, 2023, 237 (07) : 1387 - 1409
  • [43] Effect of Turbine Blade Tip Cooling Configuration on Tip Leakage Flow and Heat Transfer
    Sakaoglu, Sergen
    Kahveci, Harika S.
    JOURNAL OF TURBOMACHINERY-TRANSACTIONS OF THE ASME, 2020, 142 (02):
  • [44] Effects of blowing ratio on surface heat transfer characteristics of a transonic turbine squealer blade tip with a double plenum film cooling supply arrangement
    Fulmer, Grayson
    Ligrani, Phillip
    Collopy, Hallie
    Xu, Hongzhou
    Fox, Michael
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2024, 221
  • [45] Effects of casing motion on tip leakage flow and film-cooling effectiveness of squealer tips
    Cheng, Fengna
    Chang, Haiping
    Zhang, Jingyang
    Zhang, Jingzhou
    JOURNAL OF THERMAL SCIENCE AND TECHNOLOGY, 2017, 12 (02):
  • [46] Effect of a cutback squealer and cavity depth on film-cooling effectiveness on a gas turbine blade tip
    Mhetras, Shantanu
    Narzary, Diganta
    Gao, Zhihong
    Han, Je-Chin
    JOURNAL OF TURBOMACHINERY-TRANSACTIONS OF THE ASME, 2008, 130 (02):
  • [47] The effect of rail crown film hole injection angle and blowing ratio on the flow and cooling performance of the squealer tip in a turbine blade
    Zhou, Haimeng
    Luo, Lei
    Du, Wei
    Yan, Han
    Wang, Songtao
    APPLIED THERMAL ENGINEERING, 2024, 250
  • [48] Effect of unsteady passing wake on the aerodynamic and heat transfer performance of the turbine blade squealer tip
    Jiang, Shijie
    Li, Zhigang
    Li, Jun
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART A-JOURNAL OF POWER AND ENERGY, 2023, 237 (01) : 19 - 32
  • [49] Effect of Film Position on the Flow and Heat Transfer Characteristics of Full-Ribbed Rotor Tip
    Zhou, Haimeng
    Wang, Chenglong
    Kong, Zhiqi
    Du, Wei
    Wang, Zhongqi
    FRONTIERS IN ENERGY RESEARCH, 2022, 10
  • [50] Uncertainty Quantification Analysis on Heat Transfer Characteristics and Aerodynamic Performance of Turbine Blade Squealer Tip
    Huang M.
    Li Z.-G.
    Li J.
    Song L.-M.
    Tuijin Jishu/Journal of Propulsion Technology, 2022, 43 (03):