INVESTIGATIONS OF HEAT TRANSFER AND FILM COOLING EFFECT ON A WORN SQUEALER TIP

被引:0
|
作者
Ye, Mingliang [1 ]
Yan, Xin [1 ]
机构
[1] Xi An Jiao Tong Univ, Inst Turbomachinery, Xian 710049, Peoples R China
关键词
squealer tip; wear; heat transfer; film cooling; BLADE TIP/SHROUD RUBS;
D O I
暂无
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Wear damage commonly occurs in modern gas turbine rotor blade tip due to relative movements and expansions between rotating and stationary parts. Tip wear has a significant impact on the aerodynamic, heat transfer and cooling performance of rotor blades, thus threatening the economy and safety of whole gas turbine system. Based on a simple linear wear model, this paper numerically investigates the aerodynamic, heat transfer and film cooling performance of a worn squealer tip with three starting-locations of wear (sl=25%C-ax, 50%C-ax and 75%C-ax) and five wear-depths (wd=0.82%, 1.64%, 2.46%, 3.28% and 4.10%). Firstly, based on the existing experimental data, numerical methods and grid independence are examined carefully. Then, three dimensional flow fields, total pressure loss distributions, heat transfer coefficients and film cooling effectiveness in worn squealer tip region are computed, which are compared with the original design case. The results show that, with the increase of wear depth and the movement of wear starting-location to the leading edge, the scale and intensity of cavity vortex are increased, which results in the extended high heat transfer area on cavity floor near the leading edge. Wear makes more coolant flow out of the cavity, and reduces the area-averaged film cooling effectiveness at the bottom of cavity, but increases the film cooling effectiveness on pressure-side rim. The increase of wear depth makes more flow leak through the tip gap, thus increasing the scale and intensity of leakage vortex and further increasing the total pressure loss in the tip gap. Compared with the original design case, as the wear depth is increased from 0.82% to 4.10%, the mass-averaged total pressure loss in cascade is increased by 0.3-6.7%, the area-averaged heat transfer coefficient on cavity floor is increased by 1.7-29.1% while on squealer rim it is decreased by 3.1-26.3%, and the area-averaged film cooling effectiveness on cavity floor is decreased by 0.035 at most while on squealer rim it is increased by 0.064 at most.
引用
收藏
页数:15
相关论文
共 50 条
  • [41] Study on tip leakage flow and heat transfer for a squealer tip blade
    Yang, Dian-Liang
    Feng, Zhen-Ping
    Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics, 2007, 28 (06): : 936 - 938
  • [42] Cooling Injection Effect on a Transonic Squealer Tip-Part I: Experimental Heat Transfer Results and CFD Validation
    Ma, H.
    Zhang, Q.
    He, L.
    Wang, Z.
    Wang, L.
    JOURNAL OF ENGINEERING FOR GAS TURBINES AND POWER-TRANSACTIONS OF THE ASME, 2017, 139 (05):
  • [43] Investigation of Film Cooling Effectiveness on Squealer Tip of a Gas Turbine Blade
    Yang, Dianliang
    Feng, Zhenping
    Yu, Xiaobing
    PROCEEDINGS OF THE ASME TURBO EXPO 2009, VOL 3, PTS A AND B, 2009, : 991 - 1000
  • [44] Effects of Squealer Tip Cutbacks on Tip Leakage Flow and Film-Cooling Characteristics
    Cheng F.-N.
    Chang H.-P.
    Zhang J.-Y.
    Tian X.-J.
    Du Z.-N.
    Tuijin Jishu/Journal of Propulsion Technology, 2018, 39 (01): : 125 - 133
  • [45] Influence of Tip Injection and Film Cooling for Blade Tip Flow and Heat Transfer
    Yu, Kuahai
    Hu, Liuxian
    Yang, Xi
    Yue, Zhufeng
    MATERIALS AND COMPUTATIONAL MECHANICS, PTS 1-3, 2012, 117-119 : 643 - +
  • [46] Numerical investigations into heat transfer and film cooling effect on a transonic blade endwall
    He, Kun
    Li, Jingjing
    Yan, Xin
    APPLIED THERMAL ENGINEERING, 2018, 129 : 934 - 952
  • [47] Effect of ejection angle and blowing ratio on heat transfer and film cooling effect on a winglet tip
    Yan, Xin
    Huang, Yan
    He, Kun
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2018, 125 : 357 - 374
  • [48] Uncertainty quantification of aerothermal performance of squealer tip with film cooling structure
    Huang, Ming
    Zhang, Kaiyuan
    Li, Zhigang
    Li, Jun
    Hangkong Xuebao/Acta Aeronautica et Astronautica Sinica, 2024, 45 (19):
  • [49] Numerical investigations on the steady and unsteady leakage flow and heat transfer characteristics of rotor blade squealer tip
    Jun Li
    Hao Sun
    Jinshan Wang
    Zhenping Feng
    Journal of Thermal Science, 2011, 20 : 304 - 311