INVESTIGATIONS OF HEAT TRANSFER AND FILM COOLING EFFECT ON A WORN SQUEALER TIP

被引:0
|
作者
Ye, Mingliang [1 ]
Yan, Xin [1 ]
机构
[1] Xi An Jiao Tong Univ, Inst Turbomachinery, Xian 710049, Peoples R China
关键词
squealer tip; wear; heat transfer; film cooling; BLADE TIP/SHROUD RUBS;
D O I
暂无
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Wear damage commonly occurs in modern gas turbine rotor blade tip due to relative movements and expansions between rotating and stationary parts. Tip wear has a significant impact on the aerodynamic, heat transfer and cooling performance of rotor blades, thus threatening the economy and safety of whole gas turbine system. Based on a simple linear wear model, this paper numerically investigates the aerodynamic, heat transfer and film cooling performance of a worn squealer tip with three starting-locations of wear (sl=25%C-ax, 50%C-ax and 75%C-ax) and five wear-depths (wd=0.82%, 1.64%, 2.46%, 3.28% and 4.10%). Firstly, based on the existing experimental data, numerical methods and grid independence are examined carefully. Then, three dimensional flow fields, total pressure loss distributions, heat transfer coefficients and film cooling effectiveness in worn squealer tip region are computed, which are compared with the original design case. The results show that, with the increase of wear depth and the movement of wear starting-location to the leading edge, the scale and intensity of cavity vortex are increased, which results in the extended high heat transfer area on cavity floor near the leading edge. Wear makes more coolant flow out of the cavity, and reduces the area-averaged film cooling effectiveness at the bottom of cavity, but increases the film cooling effectiveness on pressure-side rim. The increase of wear depth makes more flow leak through the tip gap, thus increasing the scale and intensity of leakage vortex and further increasing the total pressure loss in the tip gap. Compared with the original design case, as the wear depth is increased from 0.82% to 4.10%, the mass-averaged total pressure loss in cascade is increased by 0.3-6.7%, the area-averaged heat transfer coefficient on cavity floor is increased by 1.7-29.1% while on squealer rim it is decreased by 3.1-26.3%, and the area-averaged film cooling effectiveness on cavity floor is decreased by 0.035 at most while on squealer rim it is increased by 0.064 at most.
引用
收藏
页数:15
相关论文
共 50 条
  • [31] Investigations of film-cooling effectiveness on the squealer tip with various film-hole configurations in a linear cascade
    Cheng, Feng-na
    Zhang, Jing-zhou
    Chang, Hai-ping
    Zhang, Jing-yang
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2018, 117 : 344 - 357
  • [32] COOLING INJECTION EFFECT ON A TRANSONIC SQUEALER TIP - PART 1: EXPERIMENTAL HEAT TRANSFER RESULTS AND CFD VALIDATION
    Ma, H.
    Zhang, Q.
    He, L.
    Wang, Z.
    Wang, L.
    PROCEEDINGS OF THE ASME TURBO EXPO: TURBINE TECHNICAL CONFERENCE AND EXPOSITION, 2016, VOL 5A, 2016,
  • [33] Effect of casing purge flow on heat transfer and cooling performance of blade squealer tip for a gas turbine stage
    Jiang, Shijie
    Li, Zhigang
    Li, Jun
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART A-JOURNAL OF POWER AND ENERGY, 2022, 236 (02) : 224 - 240
  • [34] Uncertainty quantification in effects of geometric deviations on heat transfer and film cooling of blade squealer tip with pressure-side coolant
    You, Yulong
    Ding, Liang
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2024, 153
  • [35] Heat transfer coefficients on the squealer tip and near squealer tip regions of a gas turbine blade
    Kwak, JS
    Han, JC
    JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 2003, 125 (04): : 669 - 677
  • [36] Tip leakage flow and heat transfer characteristics with effect of trailing edge cutback on squealer tip
    Cheng F.-N.
    Chang H.-P.
    Zhang J.-Y.
    Tian X.-J.
    Du Z.-N.
    1600, Beijing University of Aeronautics and Astronautics (BUAA) (31): : 383 - 390
  • [37] Numerical investigations on the unsteady leakage flow and heat transfer characteristics of the turbine blade squealer tip
    Jiang, Shijie
    Li, Zhigang
    Li, Jun
    Song, Liming
    JOURNAL OF THE GLOBAL POWER AND PROPULSION SOCIETY, 2023, 7 : 1 - 12
  • [38] Cooling and heat transfer characteristics of high-pressure turbine blade with cutback squealer tip
    Wang W.
    Lu S.
    Ma H.
    Zhang Q.
    Teng J.
    Yu W.
    Hangkong Dongli Xuebao/Journal of Aerospace Power, 2019, 34 (10): : 2131 - 2139
  • [39] Effect of squealer geometry arrangement on a gas turbine blade tip heat transfer
    Azad, GS
    Han, JC
    Bunker, RS
    Lee, CP
    JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 2002, 124 (03): : 452 - 459
  • [40] ROTATING EFFECT ON TRANSONIC SQUEALER TIP COOLING PERFORMANCE
    Zhu, D.
    Lu, S.
    Ma, H.
    Zhang, Q.
    Teng, J.
    PROCEEDINGS OF THE ASME TURBO EXPO: TURBINE TECHNICAL CONFERENCE AND EXPOSITION, 2017, VOL 5A, 2017,