INVESTIGATIONS OF HEAT TRANSFER AND FILM COOLING EFFECT ON A WORN SQUEALER TIP

被引:0
|
作者
Ye, Mingliang [1 ]
Yan, Xin [1 ]
机构
[1] Xi An Jiao Tong Univ, Inst Turbomachinery, Xian 710049, Peoples R China
来源
PROCEEDINGS OF THE ASME TURBO EXPO: TURBOMACHINERY TECHNICAL CONFERENCE AND EXPOSITION, VOL 7B, PT I | 2020年
关键词
squealer tip; wear; heat transfer; film cooling; BLADE TIP/SHROUD RUBS;
D O I
暂无
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Wear damage commonly occurs in modern gas turbine rotor blade tip due to relative movements and expansions between rotating and stationary parts. Tip wear has a significant impact on the aerodynamic, heat transfer and cooling performance of rotor blades, thus threatening the economy and safety of whole gas turbine system. Based on a simple linear wear model, this paper numerically investigates the aerodynamic, heat transfer and film cooling performance of a worn squealer tip with three starting-locations of wear (sl=25%C-ax, 50%C-ax and 75%C-ax) and five wear-depths (wd=0.82%, 1.64%, 2.46%, 3.28% and 4.10%). Firstly, based on the existing experimental data, numerical methods and grid independence are examined carefully. Then, three dimensional flow fields, total pressure loss distributions, heat transfer coefficients and film cooling effectiveness in worn squealer tip region are computed, which are compared with the original design case. The results show that, with the increase of wear depth and the movement of wear starting-location to the leading edge, the scale and intensity of cavity vortex are increased, which results in the extended high heat transfer area on cavity floor near the leading edge. Wear makes more coolant flow out of the cavity, and reduces the area-averaged film cooling effectiveness at the bottom of cavity, but increases the film cooling effectiveness on pressure-side rim. The increase of wear depth makes more flow leak through the tip gap, thus increasing the scale and intensity of leakage vortex and further increasing the total pressure loss in the tip gap. Compared with the original design case, as the wear depth is increased from 0.82% to 4.10%, the mass-averaged total pressure loss in cascade is increased by 0.3-6.7%, the area-averaged heat transfer coefficient on cavity floor is increased by 1.7-29.1% while on squealer rim it is decreased by 3.1-26.3%, and the area-averaged film cooling effectiveness on cavity floor is decreased by 0.035 at most while on squealer rim it is increased by 0.064 at most.
引用
收藏
页数:15
相关论文
共 50 条
  • [31] Influence of wear damages on aerodynamic and heat transfer performance in squealer tip gap
    Ye, Mingliang
    He, Kun
    Yan, Xin
    APPLIED THERMAL ENGINEERING, 2019, 159
  • [32] Numerical investigation of unsteady film cooling on turbine blade squealer tip with pressure side coolant
    You, Yulong
    Ding, Liang
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2023, 143
  • [33] Heat transfer coefficients on the squealer tip and near squealer tip regions of a gas turbine blade
    Kwak, JS
    Han, JC
    JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 2003, 125 (04): : 669 - 677
  • [34] Film-Cooling Holes Design Optimization and Knowledge Mining of a Squealer Tip
    Li C.-X.
    Guo Z.-D.
    Song L.-M.
    Li J.
    Feng Z.-P.
    Tuijin Jishu/Journal of Propulsion Technology, 2019, 40 (02): : 276 - 284
  • [35] Effect of cooling-hole distributions on heat transfer and cooling effectiveness on turbine blade tip
    Huang Y.
    Yan X.
    He K.
    Li J.
    Yan, Xin, 2016, Xi'an Jiaotong University (50): : 101 - 107
  • [36] Cooling and heat transfer characteristics of high-pressure turbine blade with cutback squealer tip
    Wang W.
    Lu S.
    Ma H.
    Zhang Q.
    Teng J.
    Yu W.
    Hangkong Dongli Xuebao/Journal of Aerospace Power, 2019, 34 (10): : 2131 - 2139
  • [37] Study on Aerodynamic and Cooling Performance of Turbine Blade Squealer Tip with Film Cooling Pulsation Characteristics Considered
    Xu C.
    Li Z.
    Li J.
    Hsi-An Chiao Tung Ta Hsueh/Journal of Xi'an Jiaotong University, 2022, 56 (05): : 127 - 140
  • [38] Effect of squealer geometry arrangement on a gas turbine blade tip heat transfer
    Azad, GS
    Han, JC
    Bunker, RS
    Lee, CP
    JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 2002, 124 (03): : 452 - 459
  • [39] Investigation of Film Cooling Effectiveness on Squealer Tip of a Gas Turbine Blade
    Yang, Dianliang
    Feng, Zhenping
    Yu, Xiaobing
    PROCEEDINGS OF THE ASME TURBO EXPO 2009, VOL 3, PTS A AND B, 2009, : 991 - 1000
  • [40] Aerothermal Optimization of Film Cooling Hole Locations on the Squealer Tip of an HP Turbine Blade
    Yildiz, F.
    Alpman, E.
    Kavurmacioglu, L.
    Camci, C.
    JOURNAL OF THERMAL SCIENCE AND ENGINEERING APPLICATIONS, 2024, 16 (05)