INVESTIGATIONS OF HEAT TRANSFER AND FILM COOLING EFFECT ON A WORN SQUEALER TIP

被引:0
|
作者
Ye, Mingliang [1 ]
Yan, Xin [1 ]
机构
[1] Xi An Jiao Tong Univ, Inst Turbomachinery, Xian 710049, Peoples R China
来源
PROCEEDINGS OF THE ASME TURBO EXPO: TURBOMACHINERY TECHNICAL CONFERENCE AND EXPOSITION, VOL 7B, PT I | 2020年
关键词
squealer tip; wear; heat transfer; film cooling; BLADE TIP/SHROUD RUBS;
D O I
暂无
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Wear damage commonly occurs in modern gas turbine rotor blade tip due to relative movements and expansions between rotating and stationary parts. Tip wear has a significant impact on the aerodynamic, heat transfer and cooling performance of rotor blades, thus threatening the economy and safety of whole gas turbine system. Based on a simple linear wear model, this paper numerically investigates the aerodynamic, heat transfer and film cooling performance of a worn squealer tip with three starting-locations of wear (sl=25%C-ax, 50%C-ax and 75%C-ax) and five wear-depths (wd=0.82%, 1.64%, 2.46%, 3.28% and 4.10%). Firstly, based on the existing experimental data, numerical methods and grid independence are examined carefully. Then, three dimensional flow fields, total pressure loss distributions, heat transfer coefficients and film cooling effectiveness in worn squealer tip region are computed, which are compared with the original design case. The results show that, with the increase of wear depth and the movement of wear starting-location to the leading edge, the scale and intensity of cavity vortex are increased, which results in the extended high heat transfer area on cavity floor near the leading edge. Wear makes more coolant flow out of the cavity, and reduces the area-averaged film cooling effectiveness at the bottom of cavity, but increases the film cooling effectiveness on pressure-side rim. The increase of wear depth makes more flow leak through the tip gap, thus increasing the scale and intensity of leakage vortex and further increasing the total pressure loss in the tip gap. Compared with the original design case, as the wear depth is increased from 0.82% to 4.10%, the mass-averaged total pressure loss in cascade is increased by 0.3-6.7%, the area-averaged heat transfer coefficient on cavity floor is increased by 1.7-29.1% while on squealer rim it is decreased by 3.1-26.3%, and the area-averaged film cooling effectiveness on cavity floor is decreased by 0.035 at most while on squealer rim it is increased by 0.064 at most.
引用
收藏
页数:15
相关论文
共 50 条
  • [21] Influence of film hole arrangement on cooling and aerodynamic performance of blade tip with squealer structure
    Huang, Tong
    Li, Hui
    Su, Xinrong
    Yuan, Xin
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2024, 195
  • [22] Effect of ejection angle and blowing ratio on heat transfer and film cooling effect on a winglet tip
    Yan, Xin
    Huang, Yan
    He, Kun
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2018, 125 : 357 - 374
  • [23] Numerical investigations into heat transfer and film cooling effect on a transonic blade endwall
    He, Kun
    Li, Jingjing
    Yan, Xin
    APPLIED THERMAL ENGINEERING, 2018, 129 : 934 - 952
  • [24] Uncertainty quantification of aerothermal performance of squealer tip with film cooling structure
    Huang, Ming
    Zhang, Kaiyuan
    Li, Zhigang
    Li, Jun
    Hangkong Xuebao/Acta Aeronautica et Astronautica Sinica, 2024, 45 (19):
  • [25] Numerical investigations on the steady and unsteady leakage flow and heat transfer characteristics of rotor blade squealer tip
    Jun Li
    Hao Sun
    Jinshan Wang
    Zhenping Feng
    Journal of Thermal Science, 2011, 20 : 304 - 311
  • [26] Numerical investigation on film cooling performance and heat transfer characteristics of turbine blade squealer tips with ribs above the film holes
    Zhou, Zuohong
    Bai, Bo
    Li, Zhigang
    Li, Jun
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2025, 210
  • [27] Numerical Investigations on the Steady and Unsteady Leakage Flow and Heat Transfer Characteristics of Rotor Blade Squealer Tip
    Li, Jun
    Sun, Hao
    Wang, Jinshan
    Feng, Zhenping
    JOURNAL OF THERMAL SCIENCE, 2011, 20 (04) : 304 - 311
  • [28] Investigations of film-cooling effectiveness on the squealer tip with various film-hole configurations in a linear cascade
    Cheng, Feng-na
    Zhang, Jing-zhou
    Chang, Hai-ping
    Zhang, Jing-yang
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2018, 117 : 344 - 357
  • [30] Influence of tip clearance and cavity depth on heat transfer in a cutback squealer tip
    Wang, Weijie
    Lu, Shaopeng
    Jiang, Hongmei
    Deng, Qiusheng
    Teng, Jinfang
    Yu, Wensheng
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART G-JOURNAL OF AEROSPACE ENGINEERING, 2021, 235 (08) : 912 - 923