Comparative investigation of structural, morphological, mechanical, tribological and electrochemical properties of TiO2 films formed on Cp-Ti, Ti6Al4V and Ti45Nb alloys

被引:1
|
作者
Kovaci, H. [1 ]
Senel, K. [1 ]
Acar, M. T. [2 ]
Bozkurt, Y. B. [1 ]
Celik, A. [1 ]
机构
[1] Ataturk Univ, Fac Engn, Dept Mech Engn, Erzurum, Turkiye
[2] Erzincan Binali Yildirim Univ, Fac Engn & Architecture, Dept Mech Engn, Erzincan, Turkiye
关键词
Titanium; Friction; Wear; Corrosion; TiO2; TITANIUM-ALLOYS; SURFACE MODIFICATION; NANOTUBES;
D O I
10.1016/j.surfcoat.2024.131024
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
This study focuses on the comparison of structural, morphological, mechanical, tribological and electrochemical properties of TiO2 films fabricated on Cp-Ti, Ti6Al4V and Ti45Nb alloys, which are widely used in different industries. For this purpose, TiO2 films were grown on Cp-Ti, Ti6Al4V and Ti45Nb materials by anodization method. Structural, morphological and mechanical properties of the samples were determined using XRD, SEM, Micro Raman, contact angle, surface roughness and micro hardness devices. Afterwards, the samples were subjected to wear and corrosion tests using a pin-on-disc wear device and a corrosion device, respectively. Wear tests were carried out in both dry and liquid environments. In electrochemical corrosion tests, Ringer's solution was used and open circuit potential (OCP) and electrochemical polarization analyzes were performed. According to the results of XRD and Raman analyses, it was determined that TiO2 films were successfully grown on the surface of the samples. Additionally, it was observed that these films were in Rutile and Anatase phases and their peak intensities increased with increasing anodization time. While the thickest films were obtained from Ti45Nb samples, the thinnest films were obtained from Cp-Ti samples. As a result of the increase in surface roughness with anodization, surface wettability increased in all samples. It was seen that electrical resistance of the materials was highly effective on the film thickness, surface roughness and surface structures. Wear coefficients decreased in all samples for both dry and liquid wear conditions due to the increased surface hardness and anodic film thickness and the lowest wear coefficients were obtained from the Ti45Nb sample. Corrosion performance of the samples increased with anodization because TiO2 films acted as protective layers on surface of materials.
引用
收藏
页数:14
相关论文
共 50 条
  • [21] The investigation of die-pressing and sintering behavior of ITP CP-Ti and Ti-6Al-4V powders
    Chen, W.
    Yamamoto, Y.
    Peter, W. H.
    Clark, M. B.
    Nunn, S. D.
    Kiggans, J. O.
    Muth, T. R.
    Blue, C. A.
    Williams, J. C.
    Akhtar, K.
    JOURNAL OF ALLOYS AND COMPOUNDS, 2012, 541 : 440 - 447
  • [22] Dual Electrochemical Treatments to Improve Properties of Ti6Al4V Alloy
    Rossi, Stefano
    Volgare, Luciana
    Perrin-Pellegrino, Carine
    Chassigneux, Carine
    Dousset, Erick
    Eyraud, Marielle
    MATERIALS, 2020, 13 (11)
  • [23] Influence of Bio-Lubricants on the Tribological Properties of Ti6Al4V Alloy
    Luo, Yong
    Yang, Li
    Tian, Maocai
    JOURNAL OF BIONIC ENGINEERING, 2013, 10 (01) : 84 - 89
  • [24] An investigation into the effect of Triode Plasma Oxidation (TPO) on the tribological properties of Ti6Al4V
    Banfield, S.
    Wilson, J. C. Avelar-Batista
    Cassar, G.
    Leyland, A.
    Matthews, A.
    Housden, J.
    SURFACE & COATINGS TECHNOLOGY, 2011, 206 (07) : 1955 - 1962
  • [25] Comparative study of nitrogen implantation effect on mechanical and tribological properties of Ti-6Al-4V and Ti-10Zr-10Nb-5Ta alloys
    Carquigny, Stephanie
    Takadoum, Jamal
    Ivanescu, Steliana
    EUROPEAN PHYSICAL JOURNAL-APPLIED PHYSICS, 2019, 85 (02)
  • [26] Short-term microvascular response of striated muscle to cp-Ti, Ti-6Al-4V, and Ti-6Al-7Nb
    Pennekamp, PH
    Gessmann, J
    Diedrich, O
    Burian, B
    Wimmer, MA
    Frauchiger, VM
    Kraft, CN
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2006, 24 (03) : 531 - 540
  • [27] Development of TiO2 layer produced by electrochemical treatment on Ti6Al4V alloy: its physicochemical and mechanical characterization
    Marques Hott, Marcus Vinicius
    Silva, Lorena de Azevedo
    da Silva, Sidney Nicodemos
    MATERIA-RIO DE JANEIRO, 2020, 25 (04): : 1 - 9
  • [28] Experimental and numerical investigations of interface properties of Ti6Al4V/CP-Ti/Copper composite plate prepared by explosive welding
    Mahmood, Yasir
    Chen, Peng-wan
    Bataev, I. A.
    Gao, Xin
    DEFENCE TECHNOLOGY, 2021, 17 (05) : 1592 - 1601
  • [29] Micro-arc oxidation of Ti6Al4V and Ti6Al7Nb alloys for biomedical applications
    Cimenoglu, Huseyin
    Gunyuz, Mert
    Kose, Gamze Torun
    Baydogan, Murat
    Ugurlu, Faysal
    Sener, Cem
    MATERIALS CHARACTERIZATION, 2011, 62 (03) : 304 - 311
  • [30] Investigation of wear, surface, metallurgical and mechanical properties of Ti6Al4V alloys coated with PVD method
    Ada, Hakan
    El Rubaye, Ahmed Qays Jabbar
    Asikuzun Tokeser, Elif
    Mavi, Ahmet
    Kaplan, Yavuz
    Aksoz, Sinan
    JOURNAL OF POLYTECHNIC-POLITEKNIK DERGISI, 2025, 28 (02):