Bacterial Contamination of Syringes and Fluids in Diagnostic and Interventional Neuroangiography

被引:1
|
作者
Wiesmann, Martin [1 ]
Honecker, Sophia [1 ]
Fleu, Claudia [1 ]
Franz, Christiane [1 ]
Schmiech, Manuela [2 ]
Ridwan, Hani [1 ]
Buerkle, Franziska [1 ]
Nikoubashman, Omid [1 ]
Lemmen, Sebastian [3 ]
机构
[1] RWTH Aachen Univ Hosp, Med Fac, Dept Diagnost & Intervent Neuroradiol, D-52076 Aachen, Germany
[2] RWTH Aachen Univ Hosp, Med Fac, Div Infect Control & Infect Dis, D-52076 Aachen, Germany
[3] Inst Krankenhaushyg & Klin Infektiol, Colynshofstr 57, D-52074 Aachen, Germany
关键词
angiography; bacteremia; contamination; intervention; ANTIBIOTIC-PROPHYLAXIS; BACTEREMIA; RADIOLOGY;
D O I
10.3390/tomography10050053
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
(1) Background: Bacterial contamination has been shown to occur during angiographies, although data on its frequency and relevance are sparse. Our aim was to evaluate the incidence of bacterial contamination of syringes used under sterile conditions during neuroangiographies. We sought to differentiate between contamination of the outside of the syringes and the inside and to detect the frequency, extent and germ spectrum of bacterial contamination. (2) Methods: We prospectively collected 600 samples from 100 neuroangiographies. Per angiography, fluid samples from the three routinely used syringes as well as the syringes themselves were analyzed. We analyzed the frequency and extent of contamination and determined the germ spectrum. (3) Results: The majority of samples (56.9%) were contaminated. There was no angiography that showed no contamination (0%). The outer surfaces of the syringes were contaminated significantly more frequently and to a higher extent than the inner surfaces. Both the frequency and extent of contamination of the samples increased with longer duration of angiographic procedures. Most of the bacterial species were environmental or skin germs (87.7%). (4) Conclusions: Bacterial contamination is a frequent finding during neuroangiographies, although its clinical significance is believed to be small. Bacterial contamination increases with longer duration of angiographic procedures.
引用
收藏
页码:686 / 692
页数:7
相关论文
共 50 条
  • [41] The safety and efficacy of the Angio-Seal closure device in diagnostic and interventional neuroangiography setting: a single-center experience with 1,443 closures
    Geyik, Serdar
    Yavuz, Kivilcim
    Akgoz, Ayca
    Koc, Osman
    Peynircioglu, Bora
    Cil, Barbaros
    Cekirge, Saruhan
    Saatci, Isil
    NEURORADIOLOGY, 2007, 49 (09) : 739 - 746
  • [42] A MICROBIOLOGICAL STUDY OF THE CONTAMINATION OF THE SYRINGES USED IN ANESTHESIA PRACTICE
    LESSARD, MR
    TREPANIER, CA
    GOURDEAU, M
    DENAULT, PH
    CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 1988, 35 (06): : 567 - 569
  • [45] Frequency and Pattern of MRI Diffusion Restrictions after Diagnostic Catheter Neuroangiography
    Kesseler, Elisabeth
    Tafelmeier, Svenja
    Nikoubashman, Omid
    Iancu, Anca-Maria
    Pinho, Joao
    Wiesmann, Martin
    TOMOGRAPHY, 2023, 9 (03) : 1010 - 1018
  • [46] CONTAMINATION OF STERILE FLUIDS
    TALLETT, ER
    BRITISH MEDICAL JOURNAL, 1978, 2 (6152): : 1645 - 1645
  • [47] CONTAMINATION OF INTRAVENOUS FLUIDS
    不详
    NEW ZEALAND MEDICAL JOURNAL, 1975, 81 (535) : 259 - 259
  • [48] CONTAMINATION OF AUTOCLAVED FLUIDS
    CONROY, J
    LANCET, 1972, 2 (7777): : 608 - &
  • [49] CONTAMINATION OF STERILE FLUIDS
    PROUT, G
    BRITISH MEDICAL JOURNAL, 1978, 2 (6142): : 959 - 959
  • [50] CONTAMINATION OF STERILE FLUIDS
    MARSHALL, IW
    BRITISH MEDICAL JOURNAL, 1978, 2 (6132): : 279 - 279