The Impact of Repeated Steam Sterilization Cycles on the Efficacy of Chairside Adjustment Kits for Polishing Monolithic Multi-Layered Zirconia Dental Restoration Material

被引:2
|
作者
Sayed, Mohammed E. [1 ]
Lunkad, Honey [1 ]
Mohana, Enas Jaber [2 ]
Mesawa, Sara Ahmad [2 ]
Dowairi, Fatimah Ibrahim [2 ]
Alharbi, Emad Aldeen A. [2 ]
Hakami, Hayat Ali [3 ]
Jokhadar, Hossam F. [4 ]
Alqahtani, Nasser M. [5 ]
Alshehri, Abdullah Hasan [5 ]
Alsubaiy, Ebrahim Fihaid [5 ]
Alqahtani, Saeed M. [5 ]
Mohsen, Nagam Mohammed [6 ]
Al Wadei, Mohammed H. D. [7 ]
Mattoo, Khurshid [1 ]
机构
[1] Jazan Univ, Coll Dent, Dept Prosthet Dent Sci, Jazan, Saudi Arabia
[2] Jazan Univ, Coll Dent, Intern Clin, Jazan, Saudi Arabia
[3] Jazan Univ, Coll Dent, Jazan, Saudi Arabia
[4] King Abdulaziz Univ, Fac Dent, Dept Oral & Maxillofacial Prosthodont, Jeddah, Saudi Arabia
[5] King Khalid Univ, Coll Dent, Dept Prosthodont, Abha, Saudi Arabia
[6] Private Clin, Jeddah, Saudi Arabia
[7] King Khalid Univ, Coll Dent, Dept Restorat Dent Sci, Abha, Saudi Arabia
来源
MEDICAL SCIENCE MONITOR | 2024年 / 30卷
关键词
Disinfection; Steam; Sterilization; Yttria Stabilized Tetragonal Zirconia; Denture; Partial; Fixed; SURFACE-ROUGHNESS; PHASE-TRANSFORMATION; 3; GENERATIONS; SYSTEMS; WEAR; STRENGTH; TRANSLUCENCY; PERFORMANCE; TOPOGRAPHY;
D O I
10.12659/MSM.944502
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Background: Before insertion, chairside adjustment kits are heat sterilized for positioning and polishing dental restorations. This study aimed to evaluate the effects of 2 steam sterilization cycles on the efficacy of polishing highly translucent monolithic zirconia (HTMLZ) dental restoration material. Material/Methods: 100 HTMLZ disc-shaped specimens were adjusted (grinding, finishing, polishing) with EVE Diacera kit. Two steam sterilization techniques [standard (Gp S), immediate/flash (Gp (F)] of CAK were further subgrouped based on number of sterilization cycles [cycle 1 (control), cycle 5, 10, 15, and 20 (experimental)] (n=10 each). Each subgroup accordingly was evaluated for average surface roughness (Ra) and root mean square roughness (Rq) using a profilometer. Mean and standard deviation of 5 subgroups were statistically analyzed using one-way ANOVA/post hoc Tukey's test. Scanning electron microscopy complemented Ra, Rq measurements. Statistical differences of P <= 0.05 were considered significant. Results: HTMLZ specimens in both groups showed increased (Ra/Rq) values after repeated sterilization of EVE Diacera kit, with Gp F showing lesser increase than Gp S (20 cycles). Gp F at 10 cycles and Gp S at 15 cycles showed clinically unacceptable roughness threshold (0.25 mu m). Differences between subgroups for Ra and Rq values were significant ( P <= 0.05) with less differences within groups observed in early cycles (1, 10). Results validate the manufacturer's recommendations of using flash sterilization/10 cycles for EVE Diacera kit. Conclusions: Repeated sterilization reduces efficacy of chairside adjustment kit to produce smooth surfaces on HTMLZ. This study recommends flash sterilization to a maximum of 10 times to get the clinically acceptable results of Ra and Rq.
引用
收藏
页数:14