Development of a microfluidic wearable electrochemical sensor for the non-invasive monitoring of oxidative stress biomarkers in human sweat

被引:4
|
作者
Ying, Zhiye [1 ]
Qiao, Lijuan [2 ]
Liu, Bingxin [1 ,3 ]
Gao, Li [1 ,3 ]
Zhang, Peng [1 ]
机构
[1] Qinghai Univ, Sch Mech Engn, Xining 810016, Peoples R China
[2] Qinghai Univ, Med Coll, Res Ctr Basic Med Sci, Xining 810016, Peoples R China
[3] Qinghai Univ, Qinghai Prov Key Lab Salt Lake Mat Chem Engn, Salt Lake Chem Engn Res Complex, Xining 810016, Peoples R China
来源
关键词
Oxidative stress; Wearable electrochemical sensor; Microfluidic channel; Health monitoring; LASER-INDUCED GRAPHENE; HYDROGEN-PEROXIDE; MASS-SPECTROMETRY; SELECTIVE ENRICHMENT; FACILE SYNTHESIS; TITANIA NANOPARTICLES; PROTEIN; OXYGEN; PHOSPHOPEPTIDES; MICROSPHERES;
D O I
10.1016/j.bios.2024.116502
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Oxidative stress is widely recognized as a pivotal factor contributing to numerous Central Nervous System (CNS) ailments. The concentrations of hydrogen peroxide (H2O2) and phosphorylated proteins within the human body serve as crucial indicators of oxidative stress. As such, the real-time monitoring of H2O2 and phosphorylated proteins in sweat is vital for the early identification, diagnosis, and management of diseases linked to oxidative stress. In this context, we present a novel microfluidic wearable electrochemical sensor by modifying the electrode with Prussian blue (PB) and loading sulfur-rich vacancy-containing molybdenum disulfide (MoS2-X) onto Multi-walled carbon nanotube (CNTs) to form coaxially layered CNTs/MoS2-X, which was then synthesized with highly dispersed titanium dioxide nanoparticles (TiO2) to synthesize CNTs/MoS2-X/TiO2 composites for the detection of human sweat H2O2 and phosphorylated proteins, respectively. This structure, with its sulfur vacancies and coaxial layering, significantly improved sensitivity of electrochemical sensors, allowing it to detect H2O2 in a range of 0.01-1 mM with a detection limit of 4.80 mu M, and phosphoproteins in a range of 0.01-1 mg/ mL with a threshold of 0.917 mu g/mL. Furthermore, the miniature sensor demonstrates outstanding performance in detecting analytes in both simulated and real sweat. Comprehensive biosafety assessments have validated the compatibility of the electrode material, underscoring the potential of sensor as a reliable and non-invasive method for tracking biomarkers linked to CNS disorders. This microfluidic wearable electrochemical biosensor with high performance and biosafety features shows great promise for the development of cutting-edge wearable technology devices for tracking CNS disease indicators.
引用
收藏
页数:12
相关论文
共 50 条
  • [41] A Wearable Electrochemical Sensing System for Non-Invasive Monitoring of Lithium Drug in Bipolar Disorder
    Criscuolo, Francesca
    Cantu, Filippo
    Taurino, Irene
    Carrara, Sandro
    De Micheli, Giovanni
    IEEE SENSORS JOURNAL, 2021, 21 (08) : 9649 - 9656
  • [42] Role of wearable electrochemical biosensors in monitoring renal function biomarkers in sweat: a review
    Salih, Ibrahim Luqman
    Alshatteri, Azad H.
    Omer, Khalid M.
    ANALYTICAL SCIENCES, 2024, 40 (11) : 1969 - 1986
  • [43] Graphene electrochemical transistor incorporated with gel electrolyte for wearable and non-invasive glucose monitoring
    Gao, Nan
    Zhou, Rui
    Tu, Bo
    Tao, Tian
    Song, Yongqiao
    Cai, Zhiwei
    He, Hanping
    Chang, Gang
    Wu, Yuxiang
    He, Yunbin
    ANALYTICA CHIMICA ACTA, 2023, 1239
  • [44] Wearable molecularly imprinted electrochemical sensor with integrated nanofiber-based microfluidic chip for in situ monitoring of cortisol in sweat
    Mei, Xuecui
    Yang, Jiao
    Yu, Xinge
    Peng, Zhengchun
    Zhang, Guanghui
    Li, Yingchun
    SENSORS AND ACTUATORS B-CHEMICAL, 2023, 381
  • [45] Non-invasive monitoring of saliva can be used to identify oxidative stress biomarkers in preterm and term newborn infants
    Solaz-Garcia, Alvaro
    Lara-Canton, Inmaculada
    Pena-Bautista, Carmen
    Chafer-Pericas, Consuelo
    Canada-Martinez, Antonio Jose
    Pinilla-Gonzalez, Alejandro
    Vento, Maximo
    Saenz-Gonzalez, Pilar
    ACTA PAEDIATRICA, 2021, 110 (12) : 3255 - 3260
  • [46] Design and Modeling of a Plethysmographic Wearable Sensor for Heart Failure Non-invasive Edema Monitoring
    Maurencig, S.
    Palmero, M.
    Algarin, A.
    Scagliusi, S. F.
    Perez, P.
    Martin, D.
    Huertas, G.
    Yufera, A.
    2024 IEEE BIOSENSORS CONFERENCE, BIOSENSORS 2024, 2024,
  • [47] Recent advancement in electrode materials and fabrication, microfluidic designs, and self-powered systems for wearable non-invasive electrochemical glucose monitoring
    Sanati, Alireza
    Esmaeili, Yasaman
    Bidram, Elham
    Shariati, Laleh
    Rafienia, Mohammad
    Mahshid, Sara
    Parlak, Onur
    APPLIED MATERIALS TODAY, 2022, 26
  • [48] Development of Sweat and Saliva Glucose Sensors as Alternative for Non-Invasive Blood Glucose Monitoring
    Lukito, Agrevina Ane
    Tyrayoh, Michelle
    Prasetyanto, Eko Adi
    Rukmini, Elisabeth
    INTERNATIONAL JOURNAL OF TECHNOLOGY, 2024, 15 (03) : 720 - 731
  • [49] A novel electrochemical sensor for non-invasive monitoring of lithium levels in mood disorders
    Criscuolo, Francesca
    Taurino, Irene
    Carrara, Sandro
    De Micheli, Giovanni
    2018 40TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2018, : 3825 - 3828
  • [50] Wearable Microfluidic Sensor for the Simultaneous and Continuous Monitoring of Local Sweat Rates and Electrolyte Concentrations
    Hashimoto, Yuki
    Ishihara, Takako
    Kuwabara, Kei
    Amano, Tatsuro
    Togo, Hiroyoshi
    MICROMACHINES, 2022, 13 (04)