Diagnostic Accuracy of Ultrasound and Fine-Needle Aspiration Cytology in Thyroid Malignancy

被引:1
|
作者
Boudina, Maria [1 ]
Katsamakas, Michael [2 ]
Chorti, Angeliki [3 ]
Panousis, Panagiotis [2 ]
Tzitzili, Eleni [2 ]
Tzikos, Georgios [3 ]
Chrisoulidou, Alexandra [1 ]
Valeri, Rosalia [4 ]
Ioannidis, Aris [3 ]
Papavramidis, Theodossis [3 ]
机构
[1] Theageneio Canc Hosp, Dept Endocrinol, Thessaloniki 54636, Greece
[2] Theageneio Canc Hosp, Dept Surg, Thessaloniki 54636, Greece
[3] Aristotle Univ Thessaloniki, AHEPA Univ Hosp, Propaedeut Dept Surg 1, Thessaloniki 54636, Greece
[4] Theageneio Canc Hosp, Dept Pathol, Thessaloniki 54636, Greece
来源
MEDICINA-LITHUANIA | 2024年 / 60卷 / 05期
关键词
thyroid malignancy; fine-needle aspiration; ultrasound; thyroid nodule; ASSOCIATION GUIDELINES; CANCER INCIDENCE; NODULES; ULTRASONOGRAPHY; CARCINOMA; RISK;
D O I
10.3390/medicina60050722
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: Thyroid nodule incidence is increasing due to the widespread application of ultrasonography. Fine-needle aspiration cytology is widely applied for the detection of malignancies. The aim of this study was to evaluate the predictive value of ultrasonography in thyroid cancer. Methods: This retrospective study included patients that underwent total thyroidectomy for benign thyroid disease or well-differentiated thyroid carcinoma from January 2017 to December 2022. The study population was divided into groups: the well-differentiated thyroid cancer group and the control group with benign histopathological reports. Results: In total, 192 patients were enrolled in our study; 159 patients were included in the well-differentiated thyroid cancer group and 33 patients in the control group. Statistical analysis demonstrated that ultrasonographic findings such as microcalcifications (90.4%), hypoechogenicity (89.3%), irregular margins (92.2%) and taller-than-wide shape (90.5%) were correlated to malignancy (p < 0.001). Uni- and multivariate analysis revealed that both US score (OR: 2.177; p < 0.001) and Bethesda System (OR: 1.875; p = 0.002) could predict malignancies. In terms of diagnostic accuracy, the US score displayed higher sensitivity (64.2% vs. 33.3%) and better negative predictive value (34.5% vs. 24.4%) than the Bethesda score, while both scoring systems displayed comparable specificities (90.9% vs. 100%) and positive predictive values (97.1% vs. 100%). Discussion: The malignant potential of thyroid nodules is a crucial subject, leading the decision for surgery. Ultrasonography and fine-needle aspiration cytology are pivotal examinations in the diagnostic process, with ultrasonography demonstrating better negative predictive value.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] Diagnostic efficacy and importance of fine-needle aspiration cytology of thyroid nodules
    Muratli, Asli
    Erdogan, Nilsen
    Sevim, Sezgin
    Unal, Isik
    Akyuz, Serap
    JOURNAL OF CYTOLOGY, 2014, 31 (02) : 73 - 78
  • [22] Reporting issues in diagnostic accuracy studies for fine-needle aspiration cytology
    Schmidt, Robert L.
    Barraza, Gonzalo
    ACTA OTORRINOLARINGOLOGICA ESPANOLA, 2015, 66 (03): : 183 - 183
  • [23] Fine-needle aspiration cytology of the thyroid - An appraisal
    Cramer, H
    CANCER CYTOPATHOLOGY, 2000, 90 (06) : 325 - 329
  • [24] “The Diagnostic Accuracy of Thyroid Nodule Fine-Needle Aspiration Cytology Following Thyroid Surgery: a Case–Control Study”
    Eda Demir Onal
    Fatma Saglam
    Muhammed Sacikara
    Reyhan Ersoy
    Gulnur Guler
    Bekir Cakir
    Endocrine Pathology, 2014, 25 : 297 - 301
  • [25] Fine Needle Aspiration Cytology of Thyroid Nodules: Evaluation of Diagnostic Accuracy
    Tseng, Chih-En
    Wei, Chang-Kuo
    Kuo, Chin-Sung
    Yan, Shih-Tang
    Chen, Pin-Fan
    Lien, Wei-Cheng
    Chang, Shu-Mei
    Su, Tzu-Cheng
    Tseng, Yun-Hsuan
    TZU CHI MEDICAL JOURNAL, 2008, 20 (04): : 296 - 303
  • [26] Diagnostic accuracy of fine-needle aspiration cytology of the breast in Japan: Report from the Working Group on the Accuracy of Breast Fine-Needle Aspiration Cytology of the Japanese Society of Clinical Cytology
    Yamaguchi, Rin
    Tsuchiya, Shin-Ichi
    Koshikawa, Takashi
    Ishihara, Akinori
    Masuda, Shinobu
    Maeda, Ichiro
    Takimoto, Masafumi
    Kawamoto, Masashi
    Satoh, Haruaki
    Narita, Michihiko
    Itoh, Hitoshi
    Kitamura, Takashi
    Tsuda, Yoshiko
    Ogane, Naoki
    Abe, Eiji
    Ikeda, Katsuhide
    Nakamura, Takeshi
    Kamaguchi, Harumi
    Tokoro, Yoshiro
    ONCOLOGY REPORTS, 2012, 28 (05) : 1606 - 1612
  • [27] Comparison of fine-needle aspiration with fine-needle capillary cytology in thyroid nodules
    Hatami, H.
    Samsami, M.
    Movahedinia, S.
    Salehi, B.
    Movahedinia, M.
    Ardeshir, M.
    ANNALS OF THE ROYAL COLLEGE OF SURGEONS OF ENGLAND, 2023, 105 (02) : 162 - 165
  • [28] Thyroid fine-needle aspiration cytology: Is there a place to virtual cytology?
    Gerhard, Rene
    Teixeira, Sofia
    da Rocha, Adriana Gaspar
    Schmitt, Fernando
    DIAGNOSTIC CYTOPATHOLOGY, 2013, 41 (09) : 793 - 798
  • [29] What are the ultrasound criteria for fine-needle aspiration cytology of nonpalpable thyroid nodules?
    Mandel, S. J.
    NATURE CLINICAL PRACTICE ENDOCRINOLOGY & METABOLISM, 2006, 2 (07): : 372 - 373
  • [30] What are the ultrasound criteria for fine-needle aspiration cytology of nonpalpable thyroid nodules?
    Susan J Mandel