BackgroundTraditional electrocardiography (ECG)-derived heart rate variability (HRV) and photoplethysmography (PPG)-derived "HRV" (termed PRV) have been reported interchangeably. Any potential dissociation between HRV and PRV could be due to the variability in pulse arrival time (PAT; time between heartbeat and peripheral pulse).ObjectiveThis study examined if PRV is equivalent to ECG-derived HRV and if PRV's innate error makes it a high-quality measurement separate from HRV.MethodsECG data from 1084 subjects were obtained from the PhysioNet Autonomic Aging dataset, and individual PAT dispersions for both the wrist (n = 42) and finger (n = 49) were derived from Mol et al. (Exp Gerontol. 2020; 135: 110938). A Bayesian simulation was constructed whereby the individual arrival times of the PPG wave were calculated by placing a Gaussian prior on the individual QRS-wave timings of each ECG series. The standard deviation (sigma) of the prior corresponds to the PAT dispersion from Mol et al. This was simulated 10,000 times for each PAT sigma. The root mean square of successive differences (RMSSD) and standard deviation of N-N intervals (SDNN) were calculated for both HRV and PRV. The Region of Practical Equivalence bounds (ROPE) were set a priori at +/- 0.2% of true HRV. The highest density interval (HDI) width, encompassing 95% of the posterior distribution, was calculated for each PAT sigma.ResultsThe lowest PAT sigma (2.0 SD) corresponded to 88.4% within ROPE for SDNN and 21.4% for RMSSD. As the sigma of PAT increases, the equivalence of PRV and HRV decreases for both SDNN and RMSSD. The HDI interval width increases with increasing PAT sigma, with the HDI width increasing at a higher rate for RMSSD than SDNN.ConclusionsFor individuals with greater PAT variability, PRV is not a surrogate for HRV. When considering PRV as a unique biometric measure, SDNN may have more favorable measurement properties than RMSSD, though both exhibit a non-uniform measurement error.
引用
收藏
页码:2927 / 2934
页数:8
相关论文
共 43 条
[1]   Variability of photoplethysmography peripheral pulse measurements at the ears, thumbs and toes [J].
Allen, J ;
Murray, A .
IEE PROCEEDINGS-SCIENCE MEASUREMENT AND TECHNOLOGY, 2000, 147 (06) :403-407
[2]  
[Anonymous], 2022, APPLE SUPPORT
[3]   RMSSD Is More Sensitive to Artifacts Than Frequency-Domain Parameters: Implication in Athletes? Monitoring [J].
Bourdillon, Nicolas ;
Yazdani, Sasan ;
Vesin, Jean-Marc ;
Schmitt, Laurent ;
Millet, Gregoire P. .
JOURNAL OF SPORTS SCIENCE AND MEDICINE, 2022, 21 (02) :260-266
[4]   EXERCISE TRAINING INCREASES TOTAL SYSTEMIC ARTERIAL COMPLIANCE IN HUMANS [J].
CAMERON, JD ;
DART, AM .
AMERICAN JOURNAL OF PHYSIOLOGY, 1994, 266 (02) :H693-H701
[5]  
Camm AJ, 1996, CIRCULATION, V93, P1043
[6]   A tool for time-frequency analysis of heart rate variability [J].
Carvalho, JLA ;
Rocha, AF ;
Junqueira, LF ;
Neto, JS ;
Santos, I ;
Nascimento, FAO .
PROCEEDINGS OF THE 25TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4: A NEW BEGINNING FOR HUMAN HEALTH, 2003, 25 :2574-2577
[7]  
Castaneda Denisse, 2018, Int J Biosens Bioelectron, V4, P195, DOI 10.15406/ijbsbe.2018.04.00125
[8]   Interchangeability between heart rate and photoplethysmography variabilities during sympathetic stimulations [J].
Charlot, K. ;
Cornolo, J. ;
Brugniaux, J. V. ;
Richalet, J. P. ;
Pichon, A. .
PHYSIOLOGICAL MEASUREMENT, 2009, 30 (12) :1357-1369
[9]   The Effect of Body Position on Measures of Arterial Stiffness in Humans [J].
Cohen, Jeremy ;
Pignanelli, Christopher ;
Burr, Jamie .
JOURNAL OF VASCULAR RESEARCH, 2020, 57 (03) :143-151
[10]   Effect of 4 weeks of aerobic or resistance exercise training on arterial stiffness, blood flow and blood pressure in pre- and stage-1 hypertensives [J].
Collier, S. R. ;
Kanaley, J. A. ;
Carhart, R., Jr. ;
Frechette, V. ;
Tobin, M. M. ;
Hall, A. K. ;
Luckenbaugh, A. N. ;
Fernhall, B. .
JOURNAL OF HUMAN HYPERTENSION, 2008, 22 (10) :678-686