The application value of a vendor-specific deep learning image reconstruction algorithm in "triple low" head and neck computed tomography angiography

被引:2
|
作者
Zhang, Qiushuang [1 ]
Lin, Youyou [1 ,2 ]
Zhang, Hailun [1 ]
Ding, Jianrong [1 ,3 ]
Pan, Jingli [1 ]
Zhang, Shuai [4 ]
机构
[1] Wenzhou Med Univ, Taizhou Hosp Zhejiang Prov Affiliated, Dept Radiol, 150 Ximen St, Linhai 317000, Peoples R China
[2] Enze Hosp, Dept Radiol, Taizhou Enze Med Ctr Grp, Taizhou, Peoples R China
[3] Key Lab Evidence Based Radiol Taizhou, 34 Dongdu North Rd, Linhai 317000, Peoples R China
[4] GE Healthcare China, CT Imaging Res Ctr, Shanghai, Peoples R China
关键词
Computed tomography angiography (CTA); radiation dosage; deep learning; triple-low technologies; CT ANGIOGRAPHY; ITERATIVE RECONSTRUCTION;
D O I
10.21037/qims-23-1602
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Head and neck computed tomography angiography (CTA) technology has become the noninvasive imaging method of choice for the diagnosis and long-term follow-up of vascular lesions of the head and neck. However, issues of radiation safety and contrast nephropathy associated with CTA examinations remain concerns. In recent years, deep learning image reconstruction (DLIR) algorithms have been increasingly used in clinical studies, demonstrating their potential for dose optimization. This study aimed to investigate the value of using a DLIR algorithm to reduce radiation and contrast doses in head and neck CTA. Methods: A total of 100 patients were prospectively enrolled and randomly divided into two groups. Group A (50 patients) consisted of those who underwent 70-kVp CTA with a low contrast volume and injection rate and who were classified according to the reconstruction algorithm into subgroups A1 [DLIR at high weighting (DLIR-H)], A2 [DLIR at low weighting (DLIR-L)], and A3 [volume-based adaptive statistical iterative reconstruction with 50% weighting (ASIR-V50%)]. Meanwhile, group B (50 patients) consisted of those who underwent standard radiation and contrast doses at 100 kVp with ASIR-V50% reconstruction. The computed tomography (CT) attenuation, background noise, signal-to-noise ratio (SNR), contrast -tonoise ratio (CNR), and subjective image quality score (SIQS) were statistically compared for several vessels among the four groups. Results: Group A showed significant reductions in contrast dosage, injection rate, and radiation dose of 36.09%, 20.88%, and 47.80%, respectively, compared to group B (all P<0.001). The four groups differed significantly in terms of background noise (all P<0.05) with group A1 having the lowest value. Group A1 also had significantly higher SNR and CNR values compared to group B in all vessels (all P<0.05) except the M1 of the middle cerebral artery for the SNR. Group A1 also had the highest SIQS, followed by the A2, B, and A3 groups. The SIQS showed good agreement between the two reviewers in all groups, with kappa values between 0.88 and 1. Conclusions: Compared to the standard-dose protocol using 100 kVp and ASIR-V50%, a protocol of 70 kVp combined with DLIR-H significantly reduces the radiation dose, contrast dose, and injection rate in head and neck CTA while still significantly improving image quality for patients with a standard body size.
引用
收藏
页码:2955 / 2967
页数:14
相关论文
共 50 条
  • [31] Optimizing computed tomography image reconstruction for focal hepatic lesions: Deep learning image reconstruction vs iterative reconstruction
    Jaruvongvanich, Varin
    Muangsomboon, Kobkun
    Teerasamit, Wanwarang
    Suvannarerg, Voraparee
    Komoltri, Chulaluk
    Thammakittiphan, Sastrawut
    Lornimitdee, Wimonrat
    Ritsamrej, Witchuda
    Chaisue, Parinya
    Pongnapang, Napapong
    Apisarnthanarak, Piyaporn
    HELIYON, 2024, 10 (15)
  • [32] Influence of adaptive statistical iterative reconstruction algorithm on image quality in coronary computed tomography angiography
    Precht, Helle
    Thygesen, Jesper
    Gerke, Oke
    Egstrup, Kenneth
    Waaler, Dag
    Lambrechtsen, Jess
    ACTA RADIOLOGICA OPEN, 2016, 5 (12):
  • [33] Insights about cervical lymph nodes: Evaluating deep learning-based reconstruction for head and neck computed tomography scan
    Lin, Yu-Han
    Su, An-Chi
    Ng, Shu-Hang
    Shen, Min-Ru
    Wu, Yu-Jie
    Chen, Ai-Chi
    Lin, Yu-Chun
    EUROPEAN JOURNAL OF RADIOLOGY OPEN, 2024, 12
  • [34] Impact of a New Adaptive Statistical Iterative Reconstruction (ASIR)-V Algorithm on Image Quality in Coronary Computed Tomography Angiography
    Pontone, Gianluca
    Muscogiuri, Giuseppe
    Andreini, Daniele
    Guaricci, Andrea, I
    Guglielmo, Marco
    Baggiano, Andrea
    Fazzari, Fabio
    Mushtaq, Saima
    Conte, Edoardo
    Annoni, Andrea
    Formenti, Alberto
    Mancini, Elisabetta
    Verdecchia, Massimo
    Campari, Alessandro
    Martini, Chiara
    Gatti, Marco
    Fusini, Laura
    Bonfanti, Lorenzo
    Consiglio, Elisa
    Rabbat, Mark G.
    Bartorelli, Antonio L.
    Pepi, Mauro
    ACADEMIC RADIOLOGY, 2018, 25 (10) : 1305 - 1313
  • [35] Dose reduction potential of vendor-agnostic deep learning model in comparison with deep learning–based image reconstruction algorithm on CT: a phantom study
    Hyunsu Choi
    Won Chang
    Jong Hyo Kim
    Chulkyun Ahn
    Heejin Lee
    Hae Young Kim
    Jungheum Cho
    Yoon Jin Lee
    Young Hoon Kim
    European Radiology, 2022, 32 : 1247 - 1255
  • [36] Evaluation of moyamoya disease in CT angiography using ultra-high-resolution computed tomography: Application of deep learning reconstruction
    Fukushima, Yasuhiro
    Fushimi, Yasutaka
    Funaki, Takeshi
    Sakata, Akihiko
    Hinoda, Takuya
    Nakajima, Satoshi
    Sakamoto, Ryo
    Yoshida, Kazumichi
    Miyamoto, Susumu
    Nakamoto, Yuji
    EUROPEAN JOURNAL OF RADIOLOGY, 2022, 151
  • [37] Deep learning image reconstruction algorithm for pancreatic protocol dual-energy computed tomography: image quality and quantification of iodine concentration
    Noda, Yoshifumi
    Kawai, Nobuyuki
    Nagata, Shoma
    Nakamura, Fumihiko
    Mori, Takayuki
    Miyoshi, Toshiharu
    Suzuki, Ryosuke
    Kitahara, Fumiya
    Kato, Hiroki
    Hyodo, Fuminori
    Matsuo, Masayuki
    EUROPEAN RADIOLOGY, 2022, 32 (01) : 384 - 394
  • [38] Deep learning-based image reconstruction for few-view computed tomography
    Yim, Dobin
    Lee, Seungwan
    Nam, Kibok
    Lee, Dahye
    Kim, Do Kyung
    Kim, Jong-Seok
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2021, 1011
  • [39] Optimizing Coronary Computed Tomography Angiography Using a Novel Deep Learning-Based Algorithm
    Dreesen, H. J. H.
    Stroszczynski, C.
    Lell, M. M.
    JOURNAL OF IMAGING INFORMATICS IN MEDICINE, 2024, 37 (04): : 1548 - 1556
  • [40] Deep learning image reconstruction algorithm for pancreatic protocol dual-energy computed tomography: image quality and quantification of iodine concentration
    Yoshifumi Noda
    Nobuyuki Kawai
    Shoma Nagata
    Fumihiko Nakamura
    Takayuki Mori
    Toshiharu Miyoshi
    Ryosuke Suzuki
    Fumiya Kitahara
    Hiroki Kato
    Fuminori Hyodo
    Masayuki Matsuo
    European Radiology, 2022, 32 : 384 - 394