O414.1 [热力学];
学科分类号
摘要
In recent years, along with the widespread use of electric vehicles (EV), EV fires have occurred frequently. However, few studies have investigated EV fires in confined spaces. To address this gap, this paper aims to explore the different aspects of fire evolution of EVs as well as examining the suppression effect of different water mist (WM) settings on these fires. Multiple simulations are carried out, using the Fire Dynamics Simulator (FDS) simulation tool, considering different numbers and working pressures of WM devices. The results highlighted that the number of WM devices had a more significant effect on the fire. Peak heat release was reduced by 17 % and peak arrival time was delayed by 26 % using 6 MPa with 3 nozzles compared to 0 nozzles. Additionally, it leads to accelerated mixing of the smoke layer with the air layer. Moreover, it was shown that the closer to the fire source in the vertical direction, the greater the degree of peak temperature decrease. In this regard, the maximum reduction in the measured temperature was around 70 %.
引用
收藏
页数:6
相关论文
共 50 条
  • [21] Experiment on Water Mist Fire Suppression in Long and Narrow Spaces
    Liu Jianghong
    Zhu Wei
    Liao Guangxuan
    PROGRESS IN SAFETY SCIENCE AND TECHNOLOGY, VOL. VIII, PTS A AND B, 2010, 8 : 798 - 806
  • [22] Progress in research and application of water mist fire suppression technology
    Liu, JH
    Liao, GX
    Li, PD
    Fan, WC
    Lu, Q
    CHINESE SCIENCE BULLETIN, 2003, 48 (08): : 718 - 725
  • [23] Progress in research and application of water mist fire suppression technology
    LIU Jianghong
    ChineseScienceBulletin, 2003, (08) : 718 - 725
  • [24] Numerical Analysis of the Characteristics of Fire-Extinguishing Performance of Water Mist Nozzle
    Kim, Hak Min
    Yeom, Jeong Kuk
    TRANSACTIONS OF THE KOREAN SOCIETY OF MECHANICAL ENGINEERS B, 2020, 44 (03) : 177 - 183
  • [25] Development of water mist fire suppression system for controlling gas burning in drilling hole
    Ligang, Zheng
    Minggao, Yu
    Shuijun, Yu
    Rongkun, Pan
    Progress in Mining Science and Safety Technology, Pts A and B, 2007, : 1646 - 1652
  • [26] Impact of Airflow Rate on Fire Suppression via Water Mist in a Mechanically Ventilated Compartment
    Acherar, Lahna
    Wang, Hui-Ying
    Coudour, Bruno
    Garo, Jean Pierre
    FIRE TECHNOLOGY, 2024, : 1557 - 1578
  • [27] Numerical analysis of how ventilation conditions impact compartment fire suppression by water mist
    Lee, Jaiho
    ANNALS OF NUCLEAR ENERGY, 2020, 136
  • [28] Novel technology for fire suppression using nitrogen-water mist in enclosed spaces
    Shi, Jingtai
    Ren, Wanxing
    Liu, Xin
    GEOMATICS NATURAL HAZARDS & RISK, 2020, 11 (01) : 22 - 39
  • [29] Experimental and numerical study on water mist suppression system on room fire
    Yang, Peizhong
    Liu, Tao
    Qin, Xian
    BUILDING AND ENVIRONMENT, 2010, 45 (10) : 2309 - 2316
  • [30] Water Spray Fire Suppression Tests Comparing Gasoline-Fuelled and Battery Electric Vehicles
    Arvidson, Magnus
    Westlund, Orjan
    FIRE TECHNOLOGY, 2023, 59 (06) : 3391 - 3414