Real-time analysis and prediction method of ion concentration using the effect of O-H stretching bands in aqueous solutions based on ATR-FTIR spectroscopy

被引:0
作者
Baek, So Hyun [1 ,2 ]
Yun, Jeungjai [1 ,3 ]
Lee, Seung-Hwan [1 ]
Lee, Hyun-Woo [1 ]
Kwon, Yongbum [1 ]
Park, Kee-Ryung [1 ]
Song, Yoseb [1 ]
Kim, Bum Sung [1 ]
Kwak, Rhokyun [3 ]
Hwang, Haejin [2 ]
Jeong, Da-Woon [1 ]
机构
[1] Korea Inst Ind Technol, Dept Korea Natl Inst Rare Met, Incheon 21655, South Korea
[2] Inha Univ, Dept Mat Sci & Engn, Incheon 22212, South Korea
[3] Hanyang Univ, Dept Mech Convergence Engn, Seoul 04763, South Korea
关键词
ELECTRICAL-CONDUCTIVITY; WATER; TEMPERATURE;
D O I
10.1039/d4ra01473a
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Analyzing the concentration of ions in aqueous solutions in real-time plays an important role in the fields of chemistry and biology. Traditional methods for measuring ion concentrations, such as concentration analysis by measuring electrical conductivity, inductively coupled plasma mass spectrometry, and ion chromatography, have been used in many research fields. However, these methods are limited in determining ion concentrations instantaneously. Fourier-transform infrared-attenuated total reflectance (ATR-FTIR) spectroscopy provides a new approach for determining ion concentrations in aqueous solutions. This allows for fast analysis without pretreatment and is scalable for real-time measurements. In this study, we present a method for measuring ion concentrations by examining ion-water interactions in the O-H stretching band of aqueous solutions using ATR-FTIR spectroscopy. Five aqueous solutions, namely LiCl + HCl, LiOH + HCl, LiOH, Li3PO4, and NaCl were used in the experiments and prepared at concentrations between 0.5-2 M. The ion concentrations in the prepared aqueous solutions were measured using ATR-FTIR spectroscopy. We observed that the difference in absorbance increased and decreased linearly with changes in concentration. The concentration of ions in the aqueous solution could be measured by validating the designed linear regression analysis function model. In this study, we proposed five linear regression analysis function models, all of which showed high coefficients of determination above 0.9, with the highest coefficient of determination reaching 0.9969. These results show that ATR-FTIR spectroscopy has the potential to be applied as a rapid and simple concentration analysis system. ATR-FTIR can be utilized to instantly and economically analyze changes in the concentration of a desired ion in solution. This method can be utilized as an indicator for automated control of ion concentration systems.
引用
收藏
页码:20073 / 20080
页数:8
相关论文
共 31 条