Battery-less lactate monitoring system using a non-enzymatic sensor with selectivity

被引:0
作者
Lin, Shih-Hao [1 ,2 ]
Lefeuvre, Elie [2 ]
Wang, Hsiang-Yu [1 ,3 ]
机构
[1] Natl Tsing Hua Univ, Dept Engn & Syst Sci, Hsinchu, Taiwan
[2] Univ Paris Saclay, Ctr Nanosci & Nanotechnol, CNRS, Palaiseau, France
[3] Natl Tsing Hua Univ, Inst Nucl Engn & Sci, Hsinchu, Taiwan
关键词
Point-of-care testing; Non -enzymatic sensor; Ionic liquid; Wireless power transmission; Affordable medicines; IONIC LIQUIDS; NANOPARTICLES;
D O I
10.1016/j.jtice.2024.105393
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Background: Point-of-care testing (POCT) offers exciting potential for delivering real-time and continuous measurements at an affordable price for a broad range of individuals. Nevertheless, continuous monitoring to proactively manage health and reduce healthcare expenses presents a set of formidable challenges. These hurdles predominantly revolve around ensuring the reliability of recognition elements and the long-term sustainability of power sources, notably batteries. Method: This study presents a robust lactate monitoring system that operates independently of batteries and remains unaffected by environmental conditions. The sensor's selectivity has been improved by electrografted ionic liquid. To enable sustained operation with minimal power consumption, a specially designed portable potentiostat has been used, allowing power to be supplied through a magnetoelectric transducer. Significant findings: We introduce a novel point-of-care testing (POCT) system featuring a non-enzymatic sensor with enhanced selectivity using an ionic liquid layer, an integrated hydrogel reference electrode, and wireless power for the portable potentiostat. These innovations improve electrochemical detection, ensuring high reproducibility and mobility while accommodating neutral pH samples. Moreover, sensors incorporating the ionic liquid layer displayed a linear detection range from 1 to 60 mM, with a sensitivity of 1.374 mu A/mM, and excellent specificity towards lactic acid. Furthermore, the magnetoelectric transducer and power management circuit demonstrated enhanced wireless power transfer, achieving a high transmitting power efficiency of 0.74 mW to operate detections with 11 min intervals. The system matches commercial instruments and operates with low power consumption, establishing a sustainable monitoring platform.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Non-enzymatic continuous glucose monitoring system
    Moore, Sean
    You, Byoung Hee
    Kim, Namwon
    Park, Taehyun
    Song, In-Hyouk
    MICRO & NANO LETTERS, 2018, 13 (08): : 1079 - 1084
  • [2] Review-Enzymatic and Non-Enzymatic Electrochemical Sensor for Lactate Detection in Human Biofluids
    Md Shakhih, Muhammad Faiz
    Rosslan, Anis Suzziani
    Noor, Anas Mohd
    Ramanathan, Santheraleka
    Lazim, Azwan Mat
    Wahab, Asnida Abdul
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2021, 168 (06)
  • [3] A Non-Enzymatic Electrochemical Sensor of Cu@Co-MOF Composite for Glucose Detection with High Sensitivity and Selectivity
    Ma, Zhen-Zhen
    Wang, Yue-Shu
    Liu, Bing
    Jiao, Huan
    Xu, Ling
    CHEMOSENSORS, 2022, 10 (10)
  • [4] Non-enzymatic Glucose Sensor Based on Nickel/Carbon Composite
    Marini, Silvia
    Ben Mansour, Nabil
    Hjiri, Mokhtar
    Dhahri, Ramzi
    El Mir, Lassaad
    Espro, Claudia
    Bonavita, Anna
    Galvagno, Signorino
    Neri, Giovanni
    Leonardi, Salvatore Gianluca
    ELECTROANALYSIS, 2018, 30 (04) : 727 - 733
  • [5] A novel sensitive non-enzymatic glucose sensor
    Kang, Xin Huang
    Mai, Zhi Bin
    Zou, Xiao Yong
    Cai, Pei Xiang
    Mo, Jin Yuan
    CHINESE CHEMICAL LETTERS, 2007, 18 (02) : 189 - 191
  • [6] A novel sensitive non-enzymatic glucose sensor
    Xin Huang Kang
    Chinese Chemical Letters, 2007, (02) : 189 - 191
  • [7] Novel design of non-enzymatic sensor for rapid monitoring of hydrogen peroxide in water matrix
    Zakaria, A. B. M.
    Leszczynska, Danuta
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2016, 766 : 30 - 36
  • [8] Nanoporous gold as non-enzymatic sensor for hydrogen peroxide
    Meng, Fanhui
    Yan, Xiuling
    Liu, Jianguo
    Gu, Jun
    Zou, Zhigang
    ELECTROCHIMICA ACTA, 2011, 56 (12) : 4657 - 4662
  • [9] Design of battery-less and real-time telemetry system for Gastrointestinal applications
    Yan Guozheng
    Huang Biao
    Peng, Zan
    2007 IEEE INTERNATIONAL CONFERENCE ON CONTROL AND AUTOMATION, VOLS 1-7, 2007, : 2737 - 2741
  • [10] NiO-MoO3 nanocomposite: A sensitive non-enzymatic sensor for glucose and urea monitoring
    Salarizadeh, Navvabeh
    Habibi-Rezaei, Mehran
    Zargar, Seyed Jalal
    MATERIALS CHEMISTRY AND PHYSICS, 2022, 281