INFLUENCE OF CAROTID ARTERY STENOSIS LOCATION ON LESION PROGRESSION USING COMPUTATIONAL FLUID DYNAMICS

被引:0
作者
Albadawi, Muhamed [1 ]
Abuouf, Yasser [1 ]
Ookawara, Shinichi [1 ]
Ahmed, Mahmoud [1 ]
机构
[1] Egypt Japan Univ Sci & Technol E JUST, Dept Energy Resources Engn, Alexandria, Egypt
来源
PROCEEDINGS OF THE ASME 2020 INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, IMECE2020, VOL 5 | 2020年
关键词
Computational Fluid Dynamics (CFD); Carotid Artery Stenosis; Atherosclerosis; Blood Dynamic Factors; WALL SHEAR-STRESS; BLOOD-FLOW; PULSATILE FLOW; PLAQUE;
D O I
暂无
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Atherosclerosis is a major arterial disease characterized by the thickening of the arteries' walls. The development of stenosis at the carotid bifurcation affects the local variations in blood flow dynamic factors. The carotid artery dynamic factors: including the wall shear stress (WSS), time-averaged wall shear stress (TAWSS) and pressure gradient affect the rate of progression of the stenosis. It is essential to analyze the flow in three-dimensional reconstructed patient-specific geometries with realistic boundary conditions to estimate the blood flow dynamic factors. Hence, a three-dimensional comprehensive model is developed including the non-Newtonian blood flow under pulsatile flow conditions. The model is numerically simulated using computational fluid dynamics solvers along with the medical imaging to investigate the effect of stenosis locations on its progression. The numerically predicted blood flow dynamic factors are analyzed. It was found that the blood flow dynamic factors have the importance to influence the diagnosis and prediction of asymptomatic carotid artery stenosis progression. Based on results, the value of TAWSS at the stenosis in the stenotic Common Carotid Artery (CCA) is 46.68 Pa comparing to 19.24 Pa and 10.049 Pa in Internal Carotid Artery (ICA) and External Carotid Artery (ECA) respectively. Also, it was found that the maximum value of WSS in the healthy artery at the bifurcation with 3.829 Pa. However, in stenotic arteries the maximum value for WSS located at the stenosis throat which was found to be 102.158 Pa for CCA comparing to 46.859 Pa in ICA and 33.658 Pa in ECA.
引用
收藏
页数:8
相关论文
共 15 条
  • [1] Study of the effect of stenosis severity and non-Newtonian viscosity on multidirectional wall shear stress and flow disturbances in the carotid artery using particle image velocimetry
    DiCarlo, Amanda L.
    Holdsworth, David W.
    Poepping, Tamie L.
    [J]. MEDICAL ENGINEERING & PHYSICS, 2019, 65 : 8 - 23
  • [2] High wall shear stress and high-risk plaque: an emerging concept
    Eshtehardi, Parham
    Brown, Adam J.
    Bhargava, Ankit
    Costopoulos, Charis
    Hung, Olivia Y.
    Corban, Michel T.
    Hosseini, Hossein
    Gogas, Bill D.
    Giddens, Don P.
    Samady, Habib
    [J]. INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2017, 33 (07) : 1089 - 1099
  • [3] A study of wall shear stress in 12 aneurysms with respect to different viscosity models and flow conditions
    Evju, Oyvind
    Valen-Sendstad, Kristian
    Mardal, Kent-Andre
    [J]. JOURNAL OF BIOMECHANICS, 2013, 46 (16) : 2802 - 2808
  • [4] The Influence of Geometrical Shapes of Stenosis on the Blood Flow in Stenosed Artery
    Kamangar, Sarfaraz
    Badruddin, Irfan Anjum
    Ahamad, N. Ameer
    Govindaraju, Kalimuthu
    Nik-Ghazali, N.
    Ahmed, N. J. Salman
    Badarudin, A.
    Khan, T. M. Yunus
    [J]. SAINS MALAYSIANA, 2017, 46 (10): : 1923 - 1933
  • [5] Numerical Investigation of the Effect of Stenosis Geometry on the Coronary Diagnostic Parameters
    Kamangar, Sarfaraz
    Kalimuthu, Govindaraju
    Badruddin, Irfan Anjum
    Badarudin, A.
    Ahmed, Salman N. J.
    Khan, T. M. Yunus
    [J]. SCIENTIFIC WORLD JOURNAL, 2014,
  • [6] PULSATILE FLOW AND ATHEROSCLEROSIS IN THE HUMAN CAROTID BIFURCATION - POSITIVE CORRELATION BETWEEN PLAQUE LOCATION AND LOW AND OSCILLATING SHEAR-STRESS
    KU, DN
    GIDDENS, DP
    ZARINS, CK
    GLAGOV, S
    [J]. ARTERIOSCLEROSIS, 1985, 5 (03): : 293 - 302
  • [7] Numerical analysis of pulsatile blood flow and vessel wall mechanics in different degrees of stenoses
    Li, M. X.
    Beech-Brandt, J. J.
    John, L. R.
    Hoskins, P. R.
    Easson, W. J.
    [J]. JOURNAL OF BIOMECHANICS, 2007, 40 (16) : 3715 - 3724
  • [8] The importance of blood rheology in patient-specific computational fluid dynamics simulation of stenotic carotid arteries
    Mendieta, Jessica Benitez
    Fontanarosa, Davide
    Wang, Jiaqiu
    Paritala, Phani Kumari
    McGahan, Tim
    Lloyd, Thomas
    Li, Zhiyong
    [J]. BIOMECHANICS AND MODELING IN MECHANOBIOLOGY, 2020, 19 (05) : 1477 - 1490
  • [9] Numerical solution of the Pulsatile, non-Newtonian and turbulent blood flow in a patient specific elastic carotid artery
    Moradicheghamahi, Jafar
    Sadeghiseraji, Jaber
    Jahangiri, Mehdi
    [J]. INTERNATIONAL JOURNAL OF MECHANICAL SCIENCES, 2019, 150 : 393 - 403
  • [10] Computational Fluid Dynamics as an Engineering Tool for the Reconstruction of Hemodynamics after Carotid Artery Stenosis Operation: A Case Study
    Polanczyk, Andrzej
    Podgorski, Michal
    Wozniak, Tomasz
    Stefanczyk, Ludomir
    Strzelecki, Michal
    [J]. MEDICINA-LITHUANIA, 2018, 54 (03):