Assessment of Efficacy of Various Bracket Base Retention Qualities on Shear Bond Strength

被引:0
作者
Tomer, Geetika [1 ]
Verghese, Yohan [2 ]
Batham, Prerna Raje [3 ]
Panika, Ashok [4 ]
Sharma, Shaivi [5 ]
Kochhar, Anuraj Singh [6 ]
Kaur, Manpreet [7 ]
机构
[1] SGT Univ, Fac Dent Sci, Dept Orthodont & Dentofacial Orthoped, Gurugram, Haryana, India
[2] Saveetha Dent Coll, Dept Orthodont, Chennai, Tamil Nadu, India
[3] Govt Coll Dent, Dept Orthodont & Dentofacial Orthoped, Indore, Madhya Pradesh, India
[4] Govt Coll Dent, Dept Orthodont & Dentofacial Orthoped, Indore, Madhya Pradesh, India
[5] Best Smile Dent Care, Dept Orthodont, Gwalior, Madhya Pradesh, India
[6] Max Hosp, Dept Orthodont, Gugaon, India
[7] Maharishi Markandeshwar Coll Dent Sci & Res, Dept Oral Pathol, Mullana, Haryana, India
关键词
Bonding; bracket base design; polymer-coated base; shear bond strength;
D O I
10.4103/jpbs.jpbs_504_23
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Introduction: Numerous manufacturers have improved bracket retention systems as a result of the frequent bond failure that occurs during orthodontic treatment. One of the elements affecting the adhesive's bond strength is the bracket retention mechanism. Objectives: This study's objective was to assess how various bracket base retention characters affected shear bond strength. Materials and Methods: Four distinct base features for brackets were evaluated. The basic design was examined using a scanning electron microscope. On the Universal testing equipment, brackets were glued to human teeth and then released. Results: The findings indicate that the polymer-coated base's overall mean SBS, which had a mean value of 21.64 +/- 4.14 MPa, was considerably greater than that of the other brackets (P 0.05). The foil meshpad, photochemically etched base, and laser-structured base had mean SBS values of 15.12 +/- 5.75 MPa, 16.86 +/- 3.76 MPa, and 19.32 +/- 4.23MPa, respectively. Conclusions: Following laser-structured base and photochemically etched base brackets in terms of shear bond strength were polymer-coated base brackets. The shear bond strength was the lowest in the plain foil mesh pads.
引用
收藏
页码:S314 / S316
页数:3
相关论文
共 7 条
  • [1] Bishara SE, 2004, ANGLE ORTHOD, V74, P400
  • [2] Chaudhary GH, 2017, APOS TRENDS ORTHOD, V7, P273, DOI 10.4103/apos.apos_91_17
  • [3] Dalaie Kazem, 2016, Eur J Dent, V10, P351, DOI 10.4103/1305-7456.184161
  • [4] Firdous W, 2022, J Adv MedDent Sci Res, V10, P160
  • [5] Fleischmann Leonardo de Aquino, 2008, Rev. Dent. Press Ortodon. Ortop. Facial, V13, P107, DOI 10.1590/S1415-54192008000400013
  • [6] Goyal A, 2013, J Indian Orthodo Soc, V47, P121
  • [7] The relationship between bond strength and orthodontic bracket base surface area with conventional and microetched foil-mesh bases
    MacColl, GA
    Rossouw, PE
    Titley, KC
    Yamin, C
    [J]. AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 1998, 113 (03) : 276 - 281