Transitioning to low GWP refrigerants in automobiles: A numerical simulation study on R1234yf/R152a's heat transfer characteristics in porous microchannels

被引:0
作者
He, Tianbiao [1 ]
Zeng, Xiangwei [2 ]
Qi, Meng [3 ]
Mao, Ning [2 ]
机构
[1] Zhejiang Univ, Inst Refrigerat & Cryogen, Key Lab Refrigerat & Cryogen Technol Zhejiang Prov, Hangzhou 310027, Peoples R China
[2] China Univ Petr East China, Coll Pipeline & Civil Engn, Dept Gas Engn, Qingdao 266580, Peoples R China
[3] China Univ Petr East China, Coll Chem & Chem Engn, Qingdao, Peoples R China
关键词
Alternative refrigerants; boiling heat transfer; numerical simulation; porous microchannels; HFC REFRIGERANTS; FLOW; R134A; PERFORMANCE; BINARY; SUBSTITUTES; MIXTURES; R152A;
D O I
10.1080/10407782.2024.2346778
中图分类号
O414.1 [热力学];
学科分类号
摘要
Automobile air conditioning systems significantly contribute to vehicle energy consumption. The transition to new, environmentally sustainable refrigerants in place of traditional ones is a critical trend shaping the future of this industry. The prevalent refrigerant R134a, used in automotive air conditioning, is environmentally detrimental, necessitating the development of low Global Warming Potential refrigerants as viable long-term alternatives. This study examines the flow heat transfer characteristics of the proposed refrigerant blend R1234yf/R152a in porous microchannel tubes via numerical simulation. It assesses the impact of heat flux, mass flow rate, saturation temperature, and wall superheat on the Jakob number, vaporization core density, and boiling heat transfer coefficient. Furthermore, it compares these parameters with those of R134a and R1234yf to evaluate the potential of R1234yf/R152a as a substitute. The findings indicate that the Jakob number differences among the three refrigerants are negligible. Notably, R1234yf/R152a consistently exhibits higher vaporization core density and the highest boiling heat transfer coefficient, coupled with the lowest pressure drop, thereby affirming its suitability as a heat transfer-efficient alternative. These insights could inform the enhancement and gradual transition from R134a in automotive air conditioning systems. HIGHLIGHTS 1.Flow heat transfer characteristics of R1234yf/R152a mixtures studied by numerical simulation. 2.The critical heat flux of the mixture in the porous microchannel is 79 kW/m(2). 3.R1234yf/R152a has better heat transfer performance compared with R134a and R1234yf refrigerants. 4.Explore the long-term substitution of low-GWP refrigerants in automobile air conditioning.
引用
收藏
页数:23
相关论文
共 38 条
  • [31] Flow boiling heat transfer capabilities of R134a low GWP substitutes inside a 4 mm id horizontal smooth tube: R600a and R152a
    Longo, Giovanni A.
    Mancin, Simone
    Righetti, Giulia
    Zilio, Claudio
    [J]. HEAT AND MASS TRANSFER, 2020, 60 (11) : 1787 - 1805
  • [32] Inhibition performance study of lubricating oil with 2-BTP on the combustion of R152a (1,1-difluoroethane) and R1234yf (2,3,3,3-tetrafluoroprop-1-ene)
    Lv, Zijian
    Yang, Zhao
    Chen, Yubo
    Zhang, Yong
    He, Hongxia
    [J]. FIRE SAFETY JOURNAL, 2022, 131
  • [33] Experimental study of heat transfer coefficient, pressure drop and flow pattern of R1234yf condensing flow in inclined plain tubes
    Moghadam, M. Tohidi
    Behabadi, M. A. Akhavan
    Sajadi, B.
    Razi, P.
    Zakaria, M. Isakhani
    [J]. INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2020, 160
  • [34] Effects of Heat Transfer Characteristics of R32 and R1234yf with Al2O3 Nanoparticle through U-Bend Tube Evaporator
    Islam, Latifur
    Mondal, Dipayan
    Islam, Md. Ashraful
    Das, Palash
    [J]. JOURNAL OF ENGINEERING, 2024, 2024
  • [35] Experimental study of the heat transfer coefficient during condensation of refrigerant R1234yf in a 4.8-mm internal diameter smooth horizontal tube
    Mendes, Ramon de Paoli
    Garcia-Pabon, Juan J.
    Bonjour, Jocelyn
    Revellin, Remi
    Machado, Luiz
    [J]. JOURNAL OF THE BRAZILIAN SOCIETY OF MECHANICAL SCIENCES AND ENGINEERING, 2023, 45 (10)
  • [36] Comparative evaluation of the evaporation heat transfer characteristics of a low-GWP refrigerant R-1234ze(E) between shell-and-plate and plate heat exchangers
    Jo, ChangUk
    Lee, DongChan
    Chung, Hyun Joon
    Kang, Yubi
    Kim, Yongchan
    [J]. INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2020, 153
  • [37] Condensation heat transfer and pressure drop characteristics of low GWP R-404A alternative refrigerants in a multiport tube having axial microfins
    Kim, Cheol-Hwan
    Kim, Nae-Hyun
    [J]. INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2022, 188
  • [38] Condensation heat and mass transfer characteristics of zeotropic refrigerant mixture R1234yf/R32 inside small-scale tube: Flow patterns observation and non-equilibrium film model calculation
    Wang, Linlin
    Dang, Chaobin
    Hihara, Eiji
    Dai, Baomin
    [J]. INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2023, 191