Effect of Different Intraoral Scanners on the Accuracy of Bite Registration in Edentulous Maxillary and Mandibular Arches

被引:2
作者
Rutkunas, Vygandas [1 ,2 ]
Jegelevicius, Darius [3 ]
Gedrimiene, Agne [1 ,2 ]
Auskalnis, Liudas [1 ,2 ]
Eyuboglu, Tan Firat [4 ]
Ozcan, Mutlu [5 ,7 ]
Husain, Nadin Al-Haj [5 ,6 ]
Akulauskas, Mykolas [3 ]
Pletkus, Justinas [2 ]
机构
[1] Vilnius Univ, Inst Odontol, Fac Med, Dept Prosthodont, Vilnius, Lithuania
[2] Digitorum Res Ctr, Vilnius, Lithuania
[3] Kaunas Univ Technol, Biomed Engn Inst, Dept Elect Engn, Kaunas, Lithuania
[4] Istanbul Medipol Univ, Fac Dent, Dept Endodont, Istanbul, Turkiye
[5] Univ Zurich, Div Dent Biomat, Clin Reconstruct Dent, Zurich, Switzerland
[6] Univ Bern, Sch Dent Med, Dept Reconstruct Dent & Gerodontol, Bern, Switzerland
[7] Univ Zurich, Ctr Dent Med, Clin Masticatory Disorders & Dent Biomat, Plattenstr 11, CH-8032 Zurich, Switzerland
关键词
Accuracy; Digital bite registration; edentulous; Intraoral scanner; Precision; Prosthodontics; Trueness; DIGITAL IMPLANT IMPRESSIONS;
D O I
10.1016/j.jdent.2024.105050
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: The objective of this study was to use in vitro models to examine the bite registration accuracy of four different intraoral scanners (IOS) for edentulous maxillary and mandibular arches. The objective was to assess the trueness and precision of the IOS and determine if there were significant differences between them. Methods: An Asiga Max UV 3D printer was used to print maxillary and mandibular edentulous models based on the shape of Frasaco models (artificial dental arch models). Four dental implants were placed symmetrically in both models using Straumann BLT RC implants. Digital impressions were taken with Primescan, Trios 3, Trios 4, and Medit i500 intraoral scanners (n = 10 for each IOS). Digital bite registrations were made, and scanning data was exported in STL format. The accuracy of the interarch distance (the distance between the metrological spheres attached to the mandibular and maxillary models) was estimated for each IOS. Results: The results showed significant differences in trueness and precision between different IOS (p <.05), except Medit i500 and Trios 3 (p >.05). Primescan provided the most accurate results, followed by Medit i500, Trios 3, and Trios 4, respectively. Conclusions: within the limitations of this study, the IOS type affects the accuracy of interocclusal bite registration in in vitro design. Only Primescan achieved clinically acceptable accuracy for the interocclusal recording of edentulous arches.
引用
收藏
页数:6
相关论文
共 36 条
  • [1] Accuracy of Intraoral Scanners: A Systematic Review of Influencing Factors
    Abduo, Jaafar
    Elseyoufi, Mohamed
    [J]. EUROPEAN JOURNAL OF PROSTHODONTICS AND RESTORATIVE DENTISTRY, 2018, 26 (03) : 101 - 121
  • [2] Applicability and accuracy of an intraoral scanner for scanning multiple implants in edentulous mandibles: A pilot study
    Andriessen, Frank S.
    Riikens, David R.
    van der Meer, Wither J.
    Wismeijer, Daniell W.
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2014, 111 (03) : 186 - 194
  • [3] Edentulous jaw impression techniques: An in vivo comparison of trueness
    Chebib, Najla
    Kalberer, Nicole
    Srinivasan, Murali
    Maniewicz, Sabrina
    Perneger, Thomas
    Mueller, Frauke
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2019, 121 (04) : 623 - 630
  • [4] In Vitro Three-Dimensional Accuracy of Digital Implant Impressions: The Effect of Implant Angulation
    Chia, Vanessa A.
    Esguerra, Roxanna J.
    Teoh, Khim Hean
    Teo, Juin Wei
    Wong, Keng Mun
    Tan, Keson B.
    [J]. INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2017, 32 (02) : 313 - 321
  • [5] Influence of roughness on surface scanning by means of a laser stripe system
    Cuesta, Eduardo
    Carlos Rico, J.
    Fernandez, Pedro
    Blanco, David
    Valino, Gonzalo
    [J]. INTERNATIONAL JOURNAL OF ADVANCED MANUFACTURING TECHNOLOGY, 2009, 43 (11-12) : 1157 - 1166
  • [6] Digital intraoral scanning technique for edentulous jaws
    Fang, Jing-Huan
    An, Xueyin
    Jeong, Seung-Mi
    Choi, Byung-Ho
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2018, 119 (05) : 733 - 735
  • [7] Development of complete dentures based on digital intraoral impressions-Case report
    Fang, Jing-Huan
    An, Xueyin
    Jeong, Seung-Mi
    Choi, Byung-Ho
    [J]. JOURNAL OF PROSTHODONTIC RESEARCH, 2018, 62 (01) : 116 - 120
  • [8] A Technique for Digital Impression and Bite Registration for a Single Edentulous Arch
    Fang, Yiqin
    Fang, Jing-Huan
    Jeong, Seung-Mi
    Choi, Byung-Ho
    [J]. JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2019, 28 (02): : E519 - E523
  • [9] CLINICAL-EVALUATION OF THE ACCURACY OF INTEROCCLUSAL RECORDING MATERIALS
    FATTORE, L
    MALONE, WF
    SANDRIK, JL
    MAZUR, B
    HART, T
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 1984, 51 (02) : 152 - 157
  • [10] Ghazal M, 2010, QUINTESSENCE INT, V41, pE31