SHORT-TERM OPTIMIZATION OF A COMBINED CYCLE POWER PLANT INTEGRATED WITH AN INLET AIR CONDITIONING UNIT

被引:0
|
作者
Mantilla, Weimar [1 ]
Garcia, Jose [1 ]
Guedez, Rafael [1 ]
Sorce, Alessandro [2 ]
机构
[1] KTH Royal Inst Technol, Heat & Power Technol, S-10044 Stockholm, Sweden
[2] Univ Genoa, Mech Engn, I-16145 Genoa, Italy
关键词
FLEXIBILITY;
D O I
暂无
中图分类号
O414.1 [热力学];
学科分类号
摘要
Under new scenarios with high shares of variable renewable electricity, combined cycle gas turbines (CCGT) are required to improve their flexibility, in terms of ramping capabilities and part-load efficiency, to help balance the power system. Simultaneously, liberalization of electricity markets and the complexity of its hourly price dynamics are affecting the CCGT profitability, leading the need for optimizing its operation. Among the different possibilities to enhance the power plant performance, an inlet air conditioning unit (ICU) offers the benefit of power augmentation and "minimum environmental load" (MEL) reduction by controlling the gas turbine inlet temperature using cold thermal energy storage and a heat pump. Consequently, an evaluation of a CCGT integrated with this inlet conditioning unit including a day-ahead optimized operation strategy was developed in this study. To establish the hourly dispatch of the power plant and the operation mode of the inlet conditioning unit to either cool down or heat up the gas turbine inlet air, a mixed-integer linear optimization (MILP) was formulated using MATLAB, aiming to maximize the operational profit of the plant within a 24-hours horizon. To assess the impact of the proposed unit operating under this dispatch strategy, historical data of electricity and natural gas prices, as well as meteorological data and CO2 emission allowances price, have been used to perform annual simulations of a reference power plant located in Turin, Italy. Furthermore, different equipment capacities and parameters have been investigated to identify trends of the power plant performance. Lastly, a sensitivity analysis on market conditions to test the control strategy response was also considered. Results indicate that the inlet conditioning unit, together with the dispatch optimization, increases the power plant's operational profit by achieving a wider operational range, particularly important during peak and off-peak periods. For the specific case study, it is estimated that the net present value of the CCGT integrated with the ICU is 0.5% higher than the power plant without the unit. In terms of technical performance, results show that the unit reduces the minimum environmental load by approximately 1.34% and can increase the net power output by 0.17% annually.
引用
收藏
页数:13
相关论文
共 50 条
  • [31] ENERGY AND EXERGY ANALYSES OF A COMBINED CYCLE POWER PLANT WITH INLET FUEL HEATING
    Chen, Ting
    Wan, Anping
    LI, Ke
    Xiang, Xingwei
    Zhou, Qinglong
    Zuo, Qing
    Zhang, Liang
    THERMAL SCIENCE, 2022, 26 (05): : 3677 - 3687
  • [32] ENERGETIC ANALYSIS AND OPTIMIZATION OF AN INTEGRATED COAL-GASIFICATION COMBINED CYCLE POWER-PLANT
    VLASWINKEL, EE
    FUEL PROCESSING TECHNOLOGY, 1992, 32 (1-2) : 47 - 67
  • [33] Optimization of a Decoupled Combined Cycle Gas Turbine Integrated in a Particle Receiver Solar Power Plant
    Valentin, Benoit
    Siros, Frederic
    Brau, Jean-Florian
    SOLARPACES 2018: INTERNATIONAL CONFERENCE ON CONCENTRATING SOLAR POWER AND CHEMICAL ENERGY SYSTEMS, 2019, 2126
  • [34] Exergy-Based Analysis and Optimization of an Integrated Solar Combined-Cycle Power Plant
    Elmorsy, Louay
    Morosuk, Tatiana
    Tsatsaronis, George
    ENTROPY, 2020, 22 (06) : 1 - 20
  • [35] Prediction Model of Short-term Electrical Load in an Air Conditioning Environment
    Palapanyakul, Kriangsak
    Siripongwutikorn, Peerapon
    2017 INTERNATIONAL ELECTRICAL ENGINEERING CONGRESS (IEECON), 2017,
  • [36] Performance analysis of a novel integrated solar combined cycle with inlet air heating system
    Wang, Shucheng
    Zhang, Gaoqiang
    Fu, Zhongguang
    APPLIED THERMAL ENGINEERING, 2019, 161
  • [37] RE-ENGINEERING OF AN INLET AIR FILTRATION SYSTEM FOR A 100MW COMBINED CYCLE COGENERATION POWER PLANT
    Dorschel, Moritz
    Wiesche, Stefan Aus Der
    PROCEEDINGS OF THE ASME POWER CONFERENCE - 2011, VOL 1, 2012, : 701 - 711
  • [38] Performance and sensitivity analysis of a combined cycle gas turbine power plant by various inlet air-cooling systems
    Rahim, Murad A.
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART A-JOURNAL OF POWER AND ENERGY, 2012, 226 (A7) : 922 - 931
  • [39] Boiler inlet duct shape design optimization for combined cycle power plants
    Prada-i-Nogueira, Isaac
    Alvarez-Ruiz, Francisco-Javier
    De-Cuadra, Fernando
    Sanchez-Miralles, Alvaro
    DYNA, 2017, 92 (05): : 525 - 531
  • [40] Optimal design and integration of an air separation unit (ASU) for an integrated gasification combined cycle (IGCC) power plant with CO2 capture
    Jones, Dustin
    Bhattacharyya, Debangsu
    Turton, Richard
    Zitney, Stephen E.
    FUEL PROCESSING TECHNOLOGY, 2011, 92 (09) : 1685 - 1695