Comparison of Legacy and New No-History IOL Power Calculation Formulas in Postmyopic Laser Vision Correction Eyes

被引:7
|
作者
Anter, Abdelrahman M. [1 ]
Bleeker, Adam R. [2 ]
Shammas, H. John [3 ,4 ]
Suraneni, Sanjana [1 ]
Kingrey, Brandon [2 ]
Murphy, David A. [2 ]
Leal, Sebastian [1 ]
Ghalibafan, Seyyedehfatemeh [1 ]
Tonk, Rahul S. [1 ]
Cooke, David L. [5 ,6 ]
Riaz, Kamran M. [2 ]
机构
[1] Univ Miami, Bascom Palmer Eye Inst, Miami, FL USA
[2] Univ Oklahoma, Dean McGee Eye Inst, Oklahoma City, OK 73104 USA
[3] Univ Southem Calif, Keck Sch Med, Dept Ophthalmol, Los Angeles, CA USA
[4] Shammas Eye Med Ctr, Lynwood, CA USA
[5] Great Lakes Eye Care, St Joseph, MI USA
[6] Michigan State Univ, Coll Osteopath Med, Dept Neurol & Ophthalmol, E Lansing, MI USA
关键词
INTRAOPERATIVE ABERROMETRY; ACCURACY; SURGERY;
D O I
10.1016/j.ajo.2024.03.014
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To compare the refractive accuracy of legacy and new no-history formulas in eyes with previous myopic laser vision correction (M-LVC). Design: Retrospective cohort study. Methods: Setting: Two academic centers Study Population: 576 eyes (400 patients) with previous M-LVC that underwent cataract surgery between 2019-2023. A SS-OCT biometer was used to obtain biometric measurements, including standard (K), posterior (PK), and total keratometry values (TK).Observation Procedures: Refractive prediction errors were calculated for 11 no-history formulas: two legacy M-LVC formulas, four new M-LVC formulas using K values only, and five new M-LVC formulas using K with PK or TK. Main Outcome Measures: Heteroscedastic testing was used to evaluate relative formula performance, and formulas were ranked by root mean square error (RMSE). Results: New M-LVC formulas performed better than legacy M-LVC formulas. New M-LVC formulas with PK/TK values performed better than versions without PK/TK values. Among new M-LVC formulas with PK/TK values, EVO 2.0-PK was superior to Hoffer QST-PK (P < 0.005). Among new M-LVC formulas using K only, Pearl DGS-K and EVO 2.0-K were both superior to Hoffer QST-K and Barrett True K NH-K formulas (all P < 0.005). Conclusions: Surgeons should favor using new no-history post M-LVC formulas over legacy post M-LVC formulas whenever possible. The top-performing M-LVC formulas (EVO 2.0-PK, Pearl DGS-PK, and Barrett True K-TK) utilized posterior corneal power values. Among formulas utilizing K alone, the EVO 2.0-K and Pearl DGS-K performed best. (c) 2024 Elsevier Inc. All rights reserved.)
引用
收藏
页码:44 / 52
页数:9
相关论文
共 50 条
  • [1] Performance of IOL calculation formulas that use measured posterior corneal power in eyes following myopic laser vision correction
    Kenny, Peter I.
    Kozhaya, Karim
    Truong, Paulina
    Wang, Li
    Koch, Douglas D.
    Weikert, Mitchell P.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2024, 50 (01): : 7 - 11
  • [2] Comparison of IOL Power Calculation Formulas for a Trifocal IOL in Eyes With High Myopia
    Tan, Qian
    Lin, Ding
    Wang, Li
    Chen, Bichao
    Tang, Qiongyan
    Chen, Xu
    Chen, Maosheng
    Tan, Jilin
    Zhang, Jingsong
    Wu, Lei
    Zhu, Xiaojun
    Wang, Yong
    JOURNAL OF REFRACTIVE SURGERY, 2021, 37 (08) : 538 - +
  • [3] Updating the no-history method in intraocular lens power calculation after myopic laser vision correction
    Shammas, H. John
    Cooke, David L.
    Riaz, Kamran M.
    Tonk, Rahul
    Shammas, Maya C.
    Bleeker, Adam
    Anter, Abdelrahman M.
    Suraneni, Sanjana
    Leal, Sebastian
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2024, 50 (10): : 1026 - 1029
  • [4] Comparison of the Accuracy of IOL Power Calculation Formulas for Pediatric Eyes in Children of Different Ages
    Kou, Jiaojiao
    Chang, Pingjun
    Lin, Lei
    Li, Zhangliang
    Fu, Yana
    Zhao, Yun-e
    JOURNAL OF OPHTHALMOLOGY, 2020, 2020
  • [5] Comparison of six IOL power calculation formulas in eyes with axial length ≤22 mm
    Wang, Li
    Gokce, Sabite
    Zeiter, John
    Weikert, Mitchell P.
    Hill, Warren
    Koch, Douglas D.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (12)
  • [6] Comparison of accuracy of recent IOL power formulas in short eyes
    Jun, Roo Min
    Gim, Yujin
    Han, Kyung Eun
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2024, 65 (07)
  • [7] Comparison of IOL Calculation Formulas for Long and Short Axial Length Eyes
    Sandhu, Umar
    Hussain, Zain S.
    Griffin, David R.
    Cooke, David L.
    Riaz, Kamran M.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2023, 64 (08)
  • [8] Comparison of IOL power calculation formulae for pediatric eyes
    Vasavada, V.
    Shah, S. K.
    Vasavada, V. A.
    Vasavada, A. R.
    Trivedi, R. H.
    Srivastava, S.
    Vasavada, S. A.
    EYE, 2016, 30 (09) : 1242 - 1250
  • [9] Comparison of IOL power calculation formulae for pediatric eyes
    V Vasavada
    S K Shah
    V A Vasavada
    A R Vasavada
    R H Trivedi
    S Srivastava
    S A Vasavada
    Eye, 2016, 30 : 1242 - 1250
  • [10] A No-History Multi-Formula Approach to Improve the IOL Power Calculation after Laser Refractive Surgery: Preliminary Results
    Cione, Ferdinando
    De Bernardo, Maddalena
    Gioia, Marco
    Oliviero, Marianunzia
    Santoro, Andrea Giuseppe
    Caputo, Alessandro
    Capasso, Luigi
    Pagliarulo, Sergio
    Rosa, Nicola
    JOURNAL OF CLINICAL MEDICINE, 2023, 12 (08)