Influence of corrosion on seismic performance of steel beam-to-column connections

被引:12
作者
Zhang, Yuelin [1 ,2 ]
Fang, Cheng [1 ,2 ]
Wang, Wei [1 ,2 ]
Wu, Lingfeng [3 ]
Cao, Peng [3 ]
机构
[1] Tongji Univ, State Key Lab Disaster Reduct Civil Engn, Shanghai 200092, Peoples R China
[2] Tongji Univ, Dept Struct Engn, Shanghai 200092, Peoples R China
[3] CHINA 22MCC Grp Corp LTD, Tangshan 064000, Hebei, Peoples R China
基金
中国国家自然科学基金;
关键词
Accelerated corrosion; Time -dependent corrosion wastage; Seismic performance evolution; Beam -to -column connection; Cover plate; Multi; -hazard; CONSTITUTIVE-EQUATIONS; STRENGTH; ALLOY; BEHAVIOR;
D O I
10.1016/j.engstruct.2024.118284
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Steel structures are not only subjected to the threaten of single hazard (e.g., earthquake), but also suffers from the coupling environmental effect such as corrosion throughout the entire service life cycle. This study explores the seismic performance of steel beam-to-column connections after corrosion. Accelerated corrosion tests were conducted on a series of practical steel beam-to-column connections, and the seismic performances of the specimens before and after corrosion were compared. A modeling method of corroded steel members that considers distribution randomness of corrosion depth was proposed. Finally, the proposed method is applied to conduct time-dependent seismic performance prediction of corroded beam-to-column connections. The results show that corrosion mainly influences the buckling and post buckling behaviors of steel beam-to-column connections. Due to earlier appearance of local buckling, more evident stiffness degradation is observed for the corroded specimen. Corrosion also induces performance degradation of the panel zone. For the corroded specimen with cover plate, multiple small cracks initiate at the junction between the cover plate and beam flange, and fracture damage is more likely to happen for the beam-to-column connections after corrosion. Both yield and ultimate load-carrying capacities of the connections decrease linearly with the increase of accelerated corrosion time, and the load-carrying capacity deterioration rate of the cover plate strengthened connection is quicker than that of the un-strengthened connection. The initial stiffness approximately degrades linearly with the increase of corrosion time. Corrosion degree also influences the energy dissipation capability of the beam-to-column connections, especially after the occurrence of local buckling.
引用
收藏
页数:20
相关论文
共 48 条
[1]   Fatigue strength of trolley bridge stringers made of ASTM A7 steel [J].
Albrecht, Pedro ;
Lenwari, Akhrawat .
JOURNAL OF BRIDGE ENGINEERING, 2008, 13 (01) :67-74
[2]  
[Anonymous], 2010, 500112010 GB
[3]  
[Anonymous], 2009, GB/T 24335-2009 Code for Classification of Earthquake Damage to Buildings and Special Structures
[4]  
[Anonymous], 2015, JGJ/T 101-2015
[5]  
ANSI, 2022, ANSI/AISC 341-22
[6]   Mechanical behavior of corroded reinforcing steel bars S500s tempcore under low cycle fatigue [J].
Apostolopoulos, Ch. Alk. .
CONSTRUCTION AND BUILDING MATERIALS, 2007, 21 (07) :1447-1456
[7]   Effect of severe corrosion on cyclic ductility of steel [J].
Bruneau, M ;
Zahrai, SM .
JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 1997, 123 (11) :1478-1486
[8]  
BS EN, 2005, BS EN 1993-1-8
[9]   TIME-INDEPENDENT CONSTITUTIVE THEORIES FOR CYCLIC PLASTICITY [J].
CHABOCHE, JL .
INTERNATIONAL JOURNAL OF PLASTICITY, 1986, 2 (02) :149-188
[10]   CONSTITUTIVE-EQUATIONS FOR CYCLIC PLASTICITY AND CYCLIC VISCOPLASTICITY [J].
CHABOCHE, JL .
INTERNATIONAL JOURNAL OF PLASTICITY, 1989, 5 (03) :247-302