Characterization of the wind-induced response of a 356 m high guyed mast based on field measurements

被引:1
|
作者
Wang, Zhe [1 ]
Liu, Muguang [1 ]
Qiao, Lei [1 ]
Luo, Hongyan [2 ]
Zhang, Chunsheng [2 ]
Xie, Zhuangning [1 ]
机构
[1] South China Univ Technol, Sch Civil Engn & Transportat, Guangzhou 510641, Guangdong, Peoples R China
[2] Meteorol Bur Shenzhen Municipal, Shenzhen Natl Climate Observ, Shenzhen 518040, Guangdong, Peoples R China
关键词
acceleration response; filed measurements; guyed mast; modal identification; probability density characteristic; STOCHASTIC SUBSPACE IDENTIFICATION; SYSTEM-IDENTIFICATION; FLUTTER DERIVATIVES; VIBRATION;
D O I
10.12989/was.2024.38.3.215
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Guyed mast structures exhibit characteristics such as high flexibility, low mass, small damping ratio, and large aspect ratio, leading to a complex wind -induced vibration response mechanism. This study analyzed the time- and frequencydomain characteristics of the wind -induced response of a guyed mast structure using measured acceleration response data obtained from the Shenzhen Meteorological Gradient Tower (SZMGT). Firstly, 734 sets of 1 -hour acceleration samples measured from 0:00 October 1, 2021, to 0:00 November 1, 2021, were selected to study the vibration shapes of the mast and the characteristics of the generalized extreme value (GEV) distribution. Secondly, six sets of typical samples with different vibration intensities were further selected to explore the Gaussian property and modal parameter characteristics of the mast. Finally, the modal parameters of the SZMGT are identified and the identification results are verified by finite element analysis. The findings revealed that the guyed mast vibration shape exhibits remarkable diversity, which increases nonlinearly along the height in most cases and reaches a maximum at the top of the tower. Moreover, the GEV distribution characteristics of the 734 sets of samples are closer to the Weibull distribution. The probability distribution of the structural wind vibration response under strong wind is in good agreement with the Gaussian distribution. The structural response of the mast under wind loading exhibits multiple modes. As the structural response escalates, the first three orders of modal energy in the tower display a gradual increase in proportion.
引用
收藏
页码:215 / 229
页数:15
相关论文
共 50 条
  • [1] Wind-induced Response Analysis of Guyed Mast Earplate Considering Welding Residual Stresses
    Wang, Wenli
    Qu, Weilian
    He, Jie
    SMART MATERIALS AND INTELLIGENT SYSTEMS, PTS 1 AND 2, 2011, 143-144 : 95 - +
  • [2] Full scale measurements of dynamic behavior and wind-induced response of guyed masts
    Deng, Hong-Zhou
    Xu, Jian-Bo
    Huang, Jian
    Wang, Zhong-Gang
    Tongji Daxue Xuebao/Journal of Tongji University, 2004, 32 (10): : 1289 - 1294
  • [3] Wind-induced Response of UHV Guyed Single-mast Transmission Tower-line System
    Yang, WenGang
    Zhu, BoWen
    Wang, ZhangQi
    ADVANCES IN CIVIL AND STRUCTURAL ENGINEERING III, PTS 1-4, 2014, 501-504 : 533 - 537
  • [4] Field measurements of the wind-induced response of a 254 m high free-standing bridge pylon
    Larose, G.L.
    Zasso, A.
    Melelli, S.
    Casanova, D.
    Journal of Wind Engineering and Industrial Aerodynamics, 1998, 74-76 : 891 - 902
  • [5] Field measurements of the wind-induced response of a 254 m high free-standing bridge pylon
    Larose, GL
    Zasso, A
    Melelli, S
    Casanova, D
    JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 1998, 74-6 : 891 - 902
  • [6] Full scale measurements of the structural response of a 50 m guyed mast under wind loading
    Harikrishna, P
    Annadurai, A
    Gomathinayagam, S
    Lakshmanan, N
    ENGINEERING STRUCTURES, 2003, 25 (07) : 859 - 867
  • [7] Towards a better understanding of the wind-induced response of towers: Field measurements
    Kwok, KCS
    Denoon, RO
    Letchford, CW
    FIRST INTERNATIONAL SYMPOSIUM ON WIND AND STRUCTURES FOR THE 21ST CENTURY, 2000, : 99 - 113
  • [8] Field measurements of wind-induced vibration of a structure
    State Key Laboratory of Turbulence and Complex Systems, Peking University, Beijing 100871, China
    Shiyan Liuti Lixue, 2006, 4 (73-76+93):
  • [9] Full-scale measurements of wind-induced response of an 84 m high concrete control tower
    Denoon, RO
    Kwok, KCS
    JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 1996, 60 (1-3) : 155 - 165
  • [10] Wind-induced fatigue analysis of high-rise guyed lattice steel towers
    Ribeiro, D.
    Braganca, C.
    Montenegro, P. A.
    Carvalho, H.
    Costa, B.
    Marques, F.
    STRUCTURES, 2022, 36 : 719 - 734