Smartphone-based particle tracking velocimetry for the in vitro assessment of coronary flows

被引:1
作者
Torta, Elena [1 ]
Griffo, Bianca [1 ]
Caridi, Giuseppe C. A. [2 ]
De Nisco, Giuseppe [1 ]
Chiastra, Claudio [1 ]
Morbiducci, Umberto [1 ]
Gallo, Diego [1 ,3 ]
机构
[1] Politecn Torino, Dept Mech & Aerosp Engn, Polito BIO Med Lab, Turin, Italy
[2] TU Wien, Inst Fluid Mech & Heat Transfer, Vienna, Austria
[3] Politecn Torino, Dept Mech & Aerosp Engn, Polito BIO Med Lab, Corso Duca degli Abruzzi 24, I-10129 Turin, Italy
关键词
Particle tracking velocimetry; Particle image velocimetry; Coronary arteries; Smartphone; Low-power laser; IMAGE VELOCIMETRY; 3-DIMENSIONAL FLOWS; PIV; HEMODYNAMICS; TIME; ATHEROSCLEROSIS; BIFURCATIONS; DYNAMICS; PTV;
D O I
10.1016/j.medengphy.2024.104144
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The present study adopts a smartphone-based approach for the experimental characterization of coronary flows. Technically, Particle Tracking Velocimetry (PTV) measurements were performed using a smartphone camera and a low-power continuous wave laser in realistic healthy and stenosed phantoms of left anterior descending artery with inflow Reynolds numbers approximately ranging from 20 to 200. A Lagrangian-Eulerian mapping was performed to convert Lagrangian PTV velocity data to a Eulerian grid. Eulerian velocity and vorticity data obtained from smartphone-based PTV measurements were compared with Particle Image Velocimetry (PIV) measurements performed with a smartphone-based setup and with a conventional setup based on a high-power double-pulsed laser and a CMOS camera. Smartphone-based PTV and PIV velocity flow fields substantially agreed with conventional PIV measurements, with the former characterized by lower average percentage differences than the latter. Discrepancies emerged at high flow regimes, especially at the stenosis throat, due to particle image blur generated by smartphone camera shutter speed and image acquisition frequency. In conclusion, the present findings demonstrate the feasibility of PTV measurements using a smartphone camera and a low-power light source for the in vitro characterization of cardiovascular flows for research, industrial and educational purposes, with advantages in terms of costs, safety and usability.
引用
收藏
页数:10
相关论文
共 52 条
[1]   PARTICLE-IMAGING TECHNIQUES FOR EXPERIMENTAL FLUID-MECHANICS [J].
ADRIAN, RJ .
ANNUAL REVIEW OF FLUID MECHANICS, 1991, 23 :261-304
[2]   Ensemble 3D PTV for high resolution turbulent statistics [J].
Aguera, Nereida ;
Cafiero, Gioacchino ;
Astarita, Tommaso ;
Discetti, Stefano .
MEASUREMENT SCIENCE AND TECHNOLOGY, 2016, 27 (12)
[3]   Tomographic Particle Image Velocimetry using Smartphones and Colored Shadows [J].
Aguirre-Pablo, Andres A. ;
Alarfaj, Meshal K. ;
Li, Er Qiang ;
Hernandez-Sanchez, J. F. ;
Thoroddsen, Sigurdur T. .
SCIENTIFIC REPORTS, 2017, 7
[4]   Experimental evaluation of a patient specific Brachio-Cephalic Arterio Venous Fistula (AVF): Velocity flow conditions under steady and pulsatile waveforms [J].
Alam, N. ;
Walsh, M. ;
Newport, D. .
MEDICAL ENGINEERING & PHYSICS, 2022, 106
[5]  
Balducci A, 2004, EXP FLUIDS, V36, P204, DOI 10.1007/S00348-003-0744-4
[6]   Hemodynamics of Stent Implantation Procedures in Coronary Bifurcations: An In Vitro Study [J].
Brindise, Melissa C. ;
Chiastra, Claudio ;
Burzotta, Francesco ;
Migliavacca, Francesco ;
Vlachos, Pavlos P. .
ANNALS OF BIOMEDICAL ENGINEERING, 2017, 45 (03) :542-553
[7]   3D flow study in a mildly stenotic coronary artery phantom using a whole volume PIV method [J].
Brunette, J. ;
Mongrain, R. ;
Laurier, J. ;
Galaz, R. ;
Tardif, J. C. .
MEDICAL ENGINEERING & PHYSICS, 2008, 30 (09) :1193-1200
[8]   Smartphone-based particle image velocimetry for cardiovascular flows applications: A focus on coronary arteries [J].
Caridi, Giuseppe C. A. ;
Torta, Elena ;
Mazzi, Valentina ;
Chiastra, Claudio ;
Audenino, Alberto L. L. ;
Morbiducci, Umberto ;
Gallo, Diego .
FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2022, 10
[9]   In Vitro, Time-Resolved PIV Comparison of the Effect of Stent Design on Wall Shear Stress [J].
Charonko, John ;
Karri, Satyaprakash ;
Schmieg, Jaime ;
Prabhu, Santosh ;
Vlachos, Pavlos .
ANNALS OF BIOMEDICAL ENGINEERING, 2009, 37 (07) :1310-1321
[10]   Quantification of disturbed coronary flow by disturbed vorticity index and relation with fractional flow reserve [J].
Chu, Miao ;
von Birgelen, Clemens ;
Li, Yingguang ;
Westra, Jelmer ;
Yang, Junqing ;
Holm, Niels R. ;
Reiber, Johan H. C. ;
Wijns, William ;
Tu, Shengxian .
ATHEROSCLEROSIS, 2018, 273 :136-144