In this study, a molecularly imprinted polymer film (MIP) was prepared on the surface of a disposable carbon screen-printed electrode (C-SPE) using (3-acrylamidopropyl)trimethylammonium chloride (AMPTMA) as a functional monomer and the cancer biomarker carbohydrate antigen 15-3 (CA 15-3) as a template. The MIP was synthesized by in situ electropolymerization (ELP) of the AMPTMA monomer in the presence of the CA 15-3 protein on the C-SPE surface. The target was subsequently removed from the polymer matrix by the action of proteinase K, resulting in imprinted cavities with a high affinity for CA 15-3. Electrochemical techniques such as cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) were used to characterize the different phases of the sensor assembly. Chemical and morphological analysis was performed using RAMAN and scanning electron microscopy (SEM). CA 15-3 was successfully detected in a wide working range from 0.001 U mL-1 to 100 U mL-1 with a correlation coefficient (R2) of 0.994 in 20 min. The MIP sensor showed minimal interference with other cancer proteins (CEA and CA 125). Overall, the developed device provides a rapid, sensitive, and cost-effective response in the detection of CA 15-3. Importantly, this comprehensive approach appears suitable for point-of-care (PoC) use, particularly in a clinical context. Here, a molecularly imprinted polymer film (MIP) was prepared on the surface of a disposable carbon screen-printed electrode (C-SPE) using (3-acrylamidopropyl)trimethylammonium chloride (AMPTMA) as a functional monomer and the cancer biomarker carbohydrate antigen 15-3 (CA 15-3) as a template.
引用
收藏
页码:15347 / 15357
页数:11
相关论文
共 48 条
[21]   Oriented Immobilization of Protein Templates: A New Trend in Surface Imprinting [J].
Kalecki, Jakub ;
Iskierko, Zofia ;
Cieplak, Maciej ;
Sharma, Piyush S. .
ACS SENSORS, 2020, 5 (12) :3710-3720
[22]  
Kwiatkowska M., 2020, Polymers, V12, P1
[23]   Evaluation of a newly developed quantitative determination kit for tumor marker CA15-3 with chemiluminescent assay [J].
Li, Peihua ;
Ye, Huiming ;
Liu, Jiangwu ;
Jin, Hongwei ;
Lin, Yongzhi ;
Yan, Shuidi ;
Yu, Yang ;
Gao, Lei ;
Xu, Feihai ;
Zhang, Zhongying .
JOURNAL OF CLINICAL LABORATORY ANALYSIS, 2018, 32 (01)
[24]   Glycosylation in breast cancer progression and mammary development: Molecular connections and malignant transformations [J].
Liang, Dongyang ;
Gao, Qian ;
Meng, Zixuan ;
Li, Wenzhe ;
Song, Jiazhe ;
Xue, Kai .
LIFE SCIENCES, 2023, 326
[25]   Postpolymerization of quaternary ammonium acrylate polymer produced by electropolymerization [J].
Lin, TY ;
Chen, MH ;
Chou, TC .
JOURNAL OF APPLIED POLYMER SCIENCE, 2001, 82 (05) :1071-1076
[26]   A sensitive electrochemiluminescence immunosensor for the detection of CA15-3 based on CeO2/Pt/rGO as a novel co-reaction accelerator [J].
Lin, Zhenbin ;
Zheng, Shaoqin ;
Xie, Jinbiao ;
Zhou, Runzhi ;
Chen, Yaowen ;
Gao, Wenhua .
TALANTA, 2023, 253
[27]   A new magnetic molecularly imprinted polymer based on deep eutectic solvents as functional monomer and cross-linker for specific recognition of bovine hemoglobin [J].
Liu, Ziwei ;
Wang, Yuzhi ;
Xu, Fangting ;
Wei, Xiaoxiao ;
Chen, Jing ;
Li, Heqiong ;
He, Xiyan ;
Zhou, Yigang .
ANALYTICA CHIMICA ACTA, 2020, 1129 :49-59
[28]   Evolution of the Raman Spectrum with the Chemical Composition of Graphene Oxide [J].
Lopez-Diaz, David ;
Lopez Holgado, Marta ;
Garcia-Fierro, Jose L. ;
Mercedes Velazquez, M. .
JOURNAL OF PHYSICAL CHEMISTRY C, 2017, 121 (37) :20489-20497
[29]   Voltammetric immunosensor for the simultaneous analysis of the breast cancer biomarkers CA 15-3 and HER2-ECD [J].
Marques, Raquel C. B. ;
Costa-Rama, Estefania ;
Viswanathan, Subramanian ;
Nouws, Henri P. A. ;
Costa-Garcia, Agustin ;
Delerue-Matos, Cristina ;
Gonzalez-Garcia, Begona .
SENSORS AND ACTUATORS B-CHEMICAL, 2018, 255 :918-925
[30]   Development of a sensor prepared by entrapment of MIP particles in electrosynthesised polymer films for electrochemical detection of ephedrine [J].
Mazzotta, E. ;
Picca, R. A. ;
Malitesta, C. ;
Piletsky, S. A. ;
Piletska, E. V. .
BIOSENSORS & BIOELECTRONICS, 2008, 23 (07) :1152-1156