Reliability of Artificial Intelligence-based Cone Beam Computed Tomography Integration with Digital Dental Images

被引:1
|
作者
Lee, Ju-Heon [1 ]
Lee, Nam-Ki [1 ]
Zou, Bingshuang [2 ]
Park, Jae Hyun [3 ,4 ]
Choi, Tae-Hyun [1 ]
机构
[1] Seoul Natl Univ, Bundang Hosp, Dept Prosthodont, Seoul, South Korea
[2] Univ British Columbia, Fac Dent, Div Orthodont, Vancouver, BC, Canada
[3] AT Still Univ, Arizona Sch Dent & Oral Hlth, Postgrad Orthodont Program, Mesa, AZ USA
[4] Kyung Hee Univ, Grad Sch Dent, Seoul, South Korea
来源
JOVE-JOURNAL OF VISUALIZED EXPERIMENTS | 2024年 / 204期
关键词
ORTHOGNATHIC SURGERY; SIMULATION; FUSION; SCAN;
D O I
10.3791/66014
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
This study aimed to introduce cone -beam computed tomography (CBCT) digitization and integration of digital dental images (DDI) based on artificial intelligence (AI) -based registration (ABR) and to evaluate the reliability and reproducibility using this method compared with those of surface -based registration (SBR). This retrospective study consisted of CBCT images and DDI of 17 patients who had undergone computer -aided bimaxillary orthognathic surgery. The digitization of CBCT images and their integration with DDI were repeated using an AI -based program. CBCT images and DDI were integrated using a point-to-point registration. In contrast, with the SBR method, the three landmarks were identified manually on the CBCT and DDI, which were integrated with the iterative closest points method. After two repeated integrations of each method, the three-dimensional coordinate values of the first maxillary molars and central incisors and their differences were obtained. Intraclass coefficient (ICC) testing was performed to evaluate intra-observer reliability with each method's coordinates and compare their reliability between the ABR and SBR. The intra-observer reliability showed significant and almost perfect ICC in each method. There was no significance in the mean difference between the first and second registrations in each ABR and SBR and between both methods; however, their ranges were narrower with ABR than with the SBR method. This study shows that AI -based digitization and integration are reliable and reproducible.
引用
收藏
页数:14
相关论文
共 50 条
  • [1] A New Method for the Integration of Digital Dental Models and Cone-beam Computed Tomography Images
    Lin, Hsiu-Hsia
    Chiang, Wen-Chung
    Lo, Lun-Jou
    Wang, Chien-Hsuan
    2013 35TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2013, : 2328 - 2331
  • [2] Comparison of digital dental images yielded by digital dental casts, cone-beam computed tomography, and multislice computed tomography for measurement of dental area
    Kang, Sang-Hoon
    Kim, Yeon-Ho
    Kim, Moon-Key
    ORAL RADIOLOGY, 2017, 33 (01) : 23 - 31
  • [3] Registration accuracy in the integration of laser-scanned dental images into maxillofacial cone-beam computed tomography images
    Noh, Hoon
    Nabha, Wael
    Cho, Jin-Hyoung
    Hwang, Hyeon-Shik
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2011, 140 (04) : 585 - 591
  • [4] Artifact-Resistant Superimposition of Digital Dental Models and Cone-Beam Computed Tomography Images
    Lin, Hsiu-Hsia
    Chiang, Wen-Chung
    Lo, Lun-Jou
    Hsu, Sam Sheng-Pin
    Wang, Chien-Hsuan
    Wan, Shu-Yen
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2013, 71 (11) : 1933 - 1947
  • [5] Automatic Superimposition of Palatal Fiducial Markers for Accurate Integration of Digital Dental Model and Cone Beam Computed Tomography
    Yang, Wei-Min
    Ho, Cheng-Ting
    Lo, Lun-Jou
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2015, 73 (08) : 1616.e1 - 1616.e10
  • [6] Accuracy and Reliability of a Novel Method for Fusion of Digital Dental Casts and Cone Beam Computed Tomography Scans
    Rangel, Frits A.
    Maal, Thomas J. J.
    Bronkhorst, Ewald M.
    Breuning, K. Hero
    Schols, Jan G. J. H.
    Berge, Stefaan J.
    Kuijpers-Jagtman, Anne Marie
    PLOS ONE, 2013, 8 (03):
  • [7] Integration of digital dental casts in cone beam computed tomography scans-a clinical validation study
    Rangel, Frits A.
    Maal, Thomas J. J.
    de Koning, Martien J. J.
    Bronkhorst, Ewald M.
    Berge, Stefaan J.
    Kuijpers-Jagtman, Anne Marie
    CLINICAL ORAL INVESTIGATIONS, 2018, 22 (03) : 1215 - 1222
  • [8] Integration accuracy of laser-scanned dental models into maxillofacial cone beam computed tomography images of different voxel sizes with different segmentation threshold settings
    Ye, Niansong
    Long, Hu
    Xue, Junjie
    Wang, Sheng
    Yang, Xin
    Lai, Wenli
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY, 2014, 117 (06): : 780 - 786
  • [9] Efficacy of Constructing Digital Hybrid Skull-Dentition Images Using an Intraoral Scanner and Cone-Beam Computed Tomography
    Lee, Joo-Hee
    Byun, Soo-Hwan
    Yi, Sang-Min
    Park, In-Young
    Yang, Byoung-Eun
    Lee, Hye-Lim
    SCANNING, 2022, 2022
  • [10] Registration of digital dental models and cone-beam computed tomography images using 3-dimensional planning software: Comparison of the accuracy according to scanning methods and software
    Park, Jin-Ho
    Hwang, Chung-Ju
    Choi, Yoon-Jeong
    Houschyar, Khosrow Siamak
    Yu, Jae-Hun
    Bae, So-Yeon
    Cha, Jung-Yul
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2020, 157 (06) : 843 - 851