Radiation doses and diagnostic reference levels for common CT scans in adults in Northwest region of Iran

被引:1
作者
Mardfar, Sina [1 ]
Ghaziyani, Mona Fazel [1 ]
Mortezazadeh, Tohid [2 ]
Zamani, Hamed [2 ]
Rahimiyan, Melika [1 ]
Khezerloo, Davood [1 ]
机构
[1] Tabriz Univ Med Sci, Fac Allied Med Sci, Dept Radiol, Tabriz, Iran
[2] Tabriz Univ Med Sci, Fac Med, Dept Med Phys, Tabriz, Iran
关键词
Computed tomography; Effective dose; Organ dose; Cancer risk; Diagnostic reference levels; Achievable doses; COMPUTED-TOMOGRAPHY EXAMINATIONS; IMAGE QUALITY; ESTABLISHMENT; SOFTWARE;
D O I
10.1007/s00411-024-01074-3
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
This study aims to estimate organ dose and cancer risks, establish region-specific diagnostic reference levels (DRLs), and determine achievable doses (ADs) for common CT procedures in adults in the northwest of Iran. Effective and organ doses were estimated using VirtualDoseCT software in a sample of 480 adult patients who underwent head, sinus, chest, and abdomen-pelvis (AP) CT scans. The guidelines provided by the BEIR VII report were utilized to estimate cancer risks. Effective and organ doses for specific procedures were determined, with the highest mean organ dose being observed in the brain during head CT examinations, with a value of 54.02 mGy. It was observed that the lungs in chest examinations and the colon in AP examinations had the highest risk of cancer, with rates of 30.72 and 21.37 per 100,000 persons, respectively. Higher cancer risk values were generally exhibited by females compared to males. The DRLs for common CT examinations were established as follows: Head CT (CTDIvol 41 mGy, DLP 760 mGy cm), Sinus CT (CTDIvol 16 mGy, DLP 261 mGy cm), Chest CT (CTDIvol 8 mGy, DLP 287 mGy cm), and AP CT (CTDIvol 9 mGy, DLP 508 mGy cm). Significant variations in dose distribution among facilities were identified, indicating the need for optimization. The study highlights the importance of minimizing radiation exposure to critical organs and promoting patient safety in CT examinations. The establishment of region-specific DRLs and ADs can help optimize radiation doses and reduce cancer risks for patients.
引用
收藏
页码:545 / 555
页数:11
相关论文
共 41 条
  • [21] Abdominal CT with low tube voltage: Preliminary observations about radiation dose, contrast enhancement, image quality, and noise
    Nakayama, Y
    Awai, K
    Funama, Y
    Hatemura, M
    Imuta, M
    Nakaura, T
    Ryu, D
    Morishita, S
    Sultana, S
    Sato, N
    Yamashita, Y
    [J]. RADIOLOGY, 2005, 237 (03) : 945 - 951
  • [22] NCRP, 2012, REFERENCE LEVELS ACH
  • [23] Paquet F., 2017, Annals of the ICRP, V46, P1, DOI [10.1177/0146645317734963, 10.1016/j.icrp.2008.08.001, 10.1016/j.icrp.2013.01.001]
  • [24] Diagnostic Reference Levels based on clinical indications in computed tomography: a literature review
    Paulo, Graciano
    Damilakis, John
    Tsapaki, Virginia
    Schegerer, Alexander A.
    Repussard, Jacques
    Jaschke, Werner
    Frija, Guy
    [J]. INSIGHTS INTO IMAGING, 2020, 11 (01)
  • [25] Evaluation of patient radiation dose and risk of cancer from CT examinations
    Poosiri, Saowapark
    Krisanachinda, Anchali
    Khamwan, Kitiwat
    [J]. RADIOLOGICAL PHYSICS AND TECHNOLOGY, 2024, 17 (01) : 176 - 185
  • [26] A comparison of the CT-dosimetry software packages based on stylized and boundary representation phantoms
    Saeed, M. K.
    [J]. RADIOGRAPHY, 2020, 26 (04) : E214 - E222
  • [27] Establishing national diagnostic reference levels (DRLs) for computed tomography in Egypt
    Salama, Dina Husseiny
    Vassileva, Jenia
    Mahdaly, Gamal
    Shawki, Mona
    Salama, Ahmad
    Gilley, Debbie
    Rehani, Madan Mohan
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2017, 39 : 16 - 24
  • [28] Determining organ dose: the holy grail
    Samei, Ehsan
    Tian, Xiaoyu
    Segars, W. Paul
    [J]. PEDIATRIC RADIOLOGY, 2014, 44 : 460 - 467
  • [29] Diagnostic reference levels and patient doses in computed tomography examinations in Greece
    Simantirakis, G.
    Hourdakis, C. J.
    Economides, S.
    Kaisas, I.
    Kalathaki, M.
    Koukorava, C.
    Manousaridis, G.
    Pafilis, C.
    Tritakis, P.
    Vogiatzi, S.
    Kamenopoulou, V.
    Dimitriou, P.
    [J]. RADIATION PROTECTION DOSIMETRY, 2015, 163 (03) : 319 - 324
  • [30] International variation in radiation dose for computed tomography examinations: prospective cohort study
    Smith-Bindman, Rebecca
    Wang, Yifei
    Chu, Philip
    Chung, Robert
    Einstein, Andrew J.
    Balcombe, Jonathan
    Cocker, Mary
    Das, Marcos
    Delman, Bradley N.
    Flynn, Michael
    Gould, Robert
    Lee, Ryan K.
    Yellen-Nelson, Thomas
    Schindera, Sebastian
    Seibert, Anthony
    Starkey, Jay
    Suntharalingam, Saravanabavaan
    Wetter, Axel
    Wildberger, Joachim E.
    Miglioretti, Diana L.
    [J]. BMJ-BRITISH MEDICAL JOURNAL, 2019, 364