Purpose The purpose of this study is to characterize and discuss the difference between software-detected non-invasive tear break-up time (NIBUT) and the traditional clinical method of fluorescein break-up time (FBUT).Methods Tear interferometry with the KOWA DR-1 alpha (Kowa, Japan) and a standardized comprehensive ocular surface/tear evaluation were performed in 307 eyes. Software-detected NIBUT in the KOWA DR-1 alpha images and the investigator-detected FBUT were compared.Results Software-detected NIBUT was significantly shorter than investigator-measured FBUT. NIBUT was 3.1 +/- 2.5 s (mean +/- SD), whereas FBUT was 4.8 +/- 3.0 s. This difference was due to three different patterns or conditions: a spot break immediately after eyelid opening, moderate to severe keratitis sicca, and epithelial basement membrane corneal dystrophy (EBMD). In these cases, rapid tear film disruption was not captured by FBUT. A spot break immediately after eye opening that rapidly disappears was observed with conjunctivochalasis. This type of break-up may be difficult to detect using fluorescein because the human eye cannot catch such rapid blinks or post-blink events. In the second group with severe corneal epithelial disease, break-up may occur over the entire corneal surface upon eye opening, and distinct fluorescein tear break-up may not be identified because of poor dye dilution or spread over the corneal surface, whereas the non-invasive break-up is not solution-dependent, and the software can detect a distinct appearance. In the third group with EBMD, it is possible that focal break-up in the fluorescein pattern over the epithelial elevations, which might be missed visually, can be detected by software in video images.Conclusion We found that software-detected NIBUT is more sensitive in detecting tear break-up, can identify certain tear film disruptions that are missed by traditional FBUT, and may be more useful in distinguishing certain tear disorders.
引用
收藏
页数:6
相关论文
共 15 条
  • [1] Clinical characteristics of patients with conjunctivochalasis
    Balci, Ozlem
    [J]. CLINICAL OPHTHALMOLOGY, 2014, 8 : 1655 - 1660
  • [2] Lid-parallel conjunctival fold (LIPCOF) morphology imaged by optical coherence tomography and its relationship to LIPCOF grade
    Bandlitz, Stefan
    Purslow, Christine
    Murphy, Paul J.
    Pult, Heiko
    [J]. CONTACT LENS & ANTERIOR EYE, 2019, 42 (03) : 299 - 303
  • [3] Dynamics and function of the tear film in relation to the blink cycle
    Braun, R. J.
    King-Smith, P. E.
    Begley, C. G.
    Li, Longfei
    Gewecke, N. R.
    [J]. PROGRESS IN RETINAL AND EYE RESEARCH, 2015, 45 : 132 - 164
  • [4] Evaluating the Differences Between Fluorescein Tear Break-up Time and Noninvasive Measurement Techniques
    Itokawa, Takashi
    Suzuki, Takashi
    Koh, Shizuka
    Hori, Yuichi
    [J]. EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2023, 49 (03): : 104 - 109
  • [5] Non-invasive and objective tear film breakup detection on interference color images using convolutional neural networks
    Kikukawa, Yasushi
    Tanaka, Shin
    Kosugi, Takuya
    Pflugfelder, Stephen C.
    [J]. PLOS ONE, 2023, 18 (03):
  • [6] Conjunctivochalasis: Literature review and possible pathophysiology
    Meller, D
    Tseng, SCG
    [J]. SURVEY OF OPHTHALMOLOGY, 1998, 43 (03) : 225 - 232
  • [7] Efficacy of the Fluorescein Tear Breakup Time Test in Dry Eye
    Paugh, Jerry R.
    Tse, June
    Nguyen, Tiffany
    Sasai, Alan
    Chen, Elaine
    De Jesus, Melinda Thomas
    Kwan, Justin
    Nguyen, Andrew Loc
    Farid, Marjan
    Garg, Sumit
    Jester, James, V
    [J]. CORNEA, 2020, 39 (01) : 92 - 98
  • [8] Non-Invasive Tear Break-Up Detection with the Kowa DR-1α and Its Relationship to Dry Eye Clinical Severity
    Pflugfelder, Stephen
    Nakhleh, Lauren
    Kikukawa, Yasushi
    Tanaka, Shin
    Kosugi, Takuya
    [J]. INTERNATIONAL JOURNAL OF MOLECULAR SCIENCES, 2022, 23 (23)
  • [9] Pflugfelder SC, 2007, OCUL SURF, V5, P163
  • [10] The cornea in keratoconjunctivitis sicca
    Pflugfelder, Stephen C.
    Stern, Michael E.
    [J]. EXPERIMENTAL EYE RESEARCH, 2020, 201