Chronopotentiometric Nanopore Sensor Based on a Stimulus-Responsive Molecularly Imprinted Polymer for Label-Free Dual-Biomarker Detection

被引:0
|
作者
Wang, Junhao [1 ,2 ,3 ]
Zhou, Huihui [4 ]
Liang, Rongning [1 ,2 ]
Qin, Wei [1 ,2 ,5 ,6 ]
机构
[1] Chinese Acad Sci, Yantai Inst Coastal Zone Res YIC, CAS Key Lab Coastal Environm Proc & Ecol Remediat, Yantai 264003, Shandong, Peoples R China
[2] YICCAS, Shandong Key Lab Coastal Environm Proc, Yantai 264003, Shandong, Peoples R China
[3] Univ Chinese Acad Sci, Beijing 100049, Peoples R China
[4] Qingdao Univ, Affiliated Yantai Yuhuangding Hosp, Yantai 264099, Shandong, Peoples R China
[5] Qingdao Natl Lab Marine Sci & Technol, Lab Marine Biol & Biotechnol, Qingdao 266237, Shandong, Peoples R China
[6] Chinese Acad Sci, Ctr Ocean Mega Sci, Qingdao 266071, Shandong, Peoples R China
基金
中国国家自然科学基金;
关键词
DETECTION LIMIT; MEMBRANE ELECTRODES; ION FLUXES; SURFACE; GLYCOPROTEINS; RECOGNITION; MODULATION; NANOSENSOR; BIOSENSOR; ANTIGEN;
D O I
10.1021/acs.analchem.3c05817
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The development of sensors for detection of biomarkers exhibits an exciting potential in diagnosis of diseases. Herein, we propose a novel electrochemical sensing strategy for label-free dual-biomarker detection, which is based on the combination of stimulus-responsive molecularly imprinted polymer (MIP)-modified nanopores and a polymeric membrane chronopotentiometric sensor. The ion fluxes galvanostatically imposed on the sensing membrane surface can be blocked by the recognition reaction between the target biomarker in the sample solution and the stimulus-responsive MIP receptor in the nanopores, thus causing a potential change. By using two external stimuli (i.e., pH and temperature), the recognition abilities of the stimulus-responsive MIP receptor can be effectively modulated so that dual-biomarker label-free chronopotentiometric detection can be achieved. Using alpha fetoprotein (AFP) and prostate-specific antigen (PSA) as model biomarkers, the proposed sensor offers detection limits of 0.17 and 0.42 ng/mL for AFP and PSA, respectively.
引用
收藏
页码:9370 / 9378
页数:9
相关论文
共 50 条
  • [31] Molecularly Imprinted Polymer-based Novel Electrochemical Sensor for the Selective Detection of Aldicarb
    Saxena, Suryansh
    Lakshmi, Garimella B. V. S.
    Chauhan, Deepika
    Solanki, Pratima R.
    PHYSICA STATUS SOLIDI A-APPLICATIONS AND MATERIALS SCIENCE, 2020, 217 (09):
  • [32] DNA based signal amplified molecularly imprinted polymer electrochemical sensor for multiplex detection
    Wang, Cong
    Guo, Zhihua
    Zhang, Li
    Zhang, Na
    Zhang, Keying
    Xu, Jigui
    Wang, Hongyang
    Shi, Hongwei
    Qin, Miao
    Ren, Lei
    RSC ADVANCES, 2016, 6 (55): : 49597 - 49603
  • [33] Label-free quantum dot conjugates for human protein IL-2 based on molecularly imprinted polymers
    Piloto, Ana Margarida L.
    Ribeiro, David S. M.
    Rodrigues, S. Sofia M.
    Santos, Joao L. M.
    Ferreira Sales, Maria Goreti
    SENSORS AND ACTUATORS B-CHEMICAL, 2020, 304 (304)
  • [34] Electrochemical platform for the detection of adenosine using a sandwich-structured molecularly imprinted polymer-based sensor
    Gliga, Laura-Elena
    Iacob, Bogdan-Cezar
    Chesches, Bianca
    Florea, Adrian
    Barbu-Tudoran, Lucian
    Bodoki, Ede
    Oprean, Radu
    ELECTROCHIMICA ACTA, 2020, 354
  • [35] Heparin molecularly imprinted polymer thin flm on gold electrode by plasma-induced graft polymerization for label-free biosensor
    Orihara, Kouhei
    Hikichi, Atsushi
    Arita, Tomohiko
    Muguruma, Hitoshi
    Yoshimi, Yasuo
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2018, 151 : 324 - 330
  • [36] A label-free immunosensor for sensitive detection of RACK 1 cancer biomarker based on conjugated polymer modified ITO electrode
    Aydin, Elif Burcu
    Aydin, Muhammet
    Sezginturk, Mustafa Kemal
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2020, 190
  • [37] Detection of cardiac biomarker proteins using a disposable based on a molecularly imprinted polymer grafted onto graphite
    Felismina T. C. Moreira
    Sanjiv Sharma
    Rosa A. F. Dutra
    João P. C. Noronha
    Anthony E. G. Cass
    M. Goreti F. Sales
    Microchimica Acta, 2015, 182 : 975 - 983
  • [38] Generic sensor platform based on electro-responsive molecularly imprinted polymer nanoparticles (e-NanoMIPs)
    Garcia-Cruz, A.
    Ahmad, O. S.
    Alanazi, K.
    Piletska, E.
    Piletsky, S. A.
    MICROSYSTEMS & NANOENGINEERING, 2020, 6 (01)
  • [39] A novel label-free fluorescent sensor for the detection of potassium ion based on DNAzyme
    Fan, Xiaoyu
    Li, Haitao
    Zhao, Jie
    Lin, Fanbo
    Zhang, Lingli
    Zhang, Youyu
    Yao, Shouzhuo
    TALANTA, 2012, 89 : 57 - 62
  • [40] A label-free optical sensor based on nanoporous gold arrays for the detection of oligodeoxynucleotides
    Feng, Jiandong
    Zhao, Weijie
    Su, Bin
    Wu, Jianmin
    BIOSENSORS & BIOELECTRONICS, 2011, 30 (01) : 21 - 27