Experimental investigation of photoelectrical performance and thermal characteristics of ventilated building-integrated photovoltaic system utilizing lightweight and flexible crystalline silicon module

被引:5
作者
Chen, Xinzhu [1 ]
Luo, Chenglong [1 ]
Ji, Jie [2 ]
Liu, Lingping [3 ]
Su, Xiaoxiao [1 ]
Yu, Yanshun [1 ]
Zhang, Hua [1 ]
Peng, Ruili [1 ]
机构
[1] Nanjing Univ Sci & Technol, Sch Energy & Power Engn, Nanjing 210094, Peoples R China
[2] Univ Sci & Technol China, Dept Thermal Sci & Energy Engn, Hefei 230027, Peoples R China
[3] Jiangxi Gangtong Energy Co Ltd, Nanchang 330001, Jiangxi, Peoples R China
基金
中国国家自然科学基金;
关键词
Ventilation; Lightweight; Low -carbon building; Photovoltaic efficiency; Thermal management; SOLAR-CELLS; BIPV; ULTRATHIN; POWER;
D O I
10.1016/j.jclepro.2024.142612
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The existing large-scale of industrial buildings with lightweight insulated roofing structures presents a challenge for traditional glass crystalline silicon photovoltaic (PV) systems due to insufficient load -bearing capacity. Meanwhile, traditional PV rooftop applications also face challenges due to limited rooftop resources. To address these issues, this study proposes a ventilated building -integrated lightweight photovoltaic (VL-BIPV) system. The VL-BIPV system incorporates lightweight and flexible crystalline silicon modules, which increase rooftop load by about 6 kg/m 2 . Additionally, the system features a ventilation channel design to enhance thermal management performance. To evaluate the PV performance and thermal characteristics of the proposed system, an experimental setup was implemented to compare the performances of the VL-BIPV system with a building -attached lightweight photovoltaic (L-BAPV) system that utilizes color steel sheet base plates. The results demonstrate the exceptional performance of VL-BIPV system, with a 100.56% higher ratio of the product of short-circuit current and open -circuit voltage compared to L-BAPV. Moreover, the VL-BIPV system achieved a 1.77% increase in PV efficiency and a 2.35% enhancement in daily electricity generation. In hot weather, the adoption of VL-BIPV reduced the extreme temperature of PV cells by 9.23 degrees C below 85 degrees C, surpassing the 6.29 degrees C reduction achieved by L-BAPV system. Furthermore, the ventilation channel exhibited a gradual temperature increase with slower changes in the flow direction, while the base plate temperature decreased by 13.41 degrees C, which indicates that VL-BIPV can effectively reduce solar heat gain in the building envelope and improve the indoor thermal environment. The research findings provide important guidance for promoting and applying VL-BIPV technology in large-scale industrial buildings with low rooftop load -bearing capacity, thereby promoting the production and utilization of clean electricity in industrial parks.
引用
收藏
页数:12
相关论文
共 63 条
[1]   Net-zero exergoeconomic and exergoenvironmental building as new concepts for developing sustainable built environments [J].
Ahmadi, Mohammad Mahdi ;
Keyhani, Alireza ;
Kalogirou, Soteris A. ;
Lam, Su Shiung ;
Peng, Wanxi ;
Tabatabaei, Meisam ;
Aghbashlo, Mortaza .
ENERGY CONVERSION AND MANAGEMENT, 2021, 244
[2]  
Arena R, 2022, Renew Energy Power Qual J, V20, P178
[3]   Integrated thinking for photovoltaics in buildings [J].
Ballif, Christophe ;
Perret-Aebi, Laure-Emmanuelle ;
Lufkin, Sophie ;
Rey, Emmanuel .
NATURE ENERGY, 2018, 3 (06) :438-442
[4]   Towards zero energy infrastructure buildings: optimal design of envelope and cooling system [J].
Barone, Giovanni ;
Buonomano, Annamaria ;
Giuzio, Giovanni Francesco ;
Palombo, Adolfo .
ENERGY, 2023, 279
[5]   Building-integrated PV modules [J].
Benemann, J ;
Chehab, O ;
Schaar-Gabriel, E .
SOLAR ENERGY MATERIALS AND SOLAR CELLS, 2001, 67 (1-4) :345-354
[6]   The tradeoff between electricity cost and CO2 emission in the optimization of photovoltaic-battery systems for buildings [J].
Chen, Qi ;
Kuang, Zhonghong ;
Liu, Xiaohua ;
Zhang, Tao .
JOURNAL OF CLEANER PRODUCTION, 2023, 386
[7]  
Commission I.E., 2008, IEC 61646: Thin-Film Terrestrial Photovoltaic (PV) Modules -Design Qualification and Type Approval
[8]   Climate response of a BiPV facade system enhanced with latent PCM-based thermal energy storage [J].
Curpek, Jakub ;
Cekon, Miroslav .
RENEWABLE ENERGY, 2020, 152 :368-384
[9]   Experimental operating cell temperature assessment of BIPV with different installation configurations on roofs under Mediterranean climate [J].
D'Orazio, M. ;
Di Perna, C. ;
Di Giuseppe, E. .
RENEWABLE ENERGY, 2014, 68 :378-396
[10]  
Fukuda K., 2022, 29 INT WORKSH ACT MA, DOI [10.23919/AM-FPD54920.2022.9851338, DOI 10.23919/AM-FPD54920.2022.9851338]