Using DFR Measurements for the Condition Assessment of Stator Winding Insulation Systems

被引:0
作者
Lachance, Mathieu [1 ]
David, Eric [2 ]
机构
[1] OMICRON Elect Canada, Toronto, ON, Canada
[2] Ecole Technol Super, Montreal, PQ, Canada
来源
2024 IEEE ELECTRICAL INSULATION CONFERENCE, EIC 2024 | 2024年
关键词
Dielectric frequency response analysis; DFR; dielectric; stator winding; frequency domain spectroscopy; FDS; DIELECTRIC RESPONSE;
D O I
10.1109/EIC58847.2024.10579416
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This publication presents the results of investigations that were performed to verify if the use of low-voltage dielectric frequency response analysis can be successfully applied to detect the deterioration of stator winding insulation systems. Three newly manufactured stator coils with a rated voltage of 13.8 kV were aged using the thermal cycle testing procedures described in IEEE 1310 and an extended and modified version of voltage endurance testing described in IEEE 1553, until dielectric failure. Throughout the accelerated ageing process, several dielectric measurements were performed, and the results trended over time. The results of the dielectric frequency response measurements were then compared with conventional dissipation factor measurements and partial discharge measurements to assess the sensitivity of dielectric frequency response analysis applied to stator insulation. This paper also discusses the influences of the nonlinear end potential grading material on the measured dielectric losses. Additional experiments are summarized to illustrate how this nonlinear material behaves depending on the applied voltage magnitude and frequency. Some examples of measurements performed on complete stator windings are also shown and discussed.
引用
收藏
页码:433 / 438
页数:6
相关论文
共 8 条
[1]  
[Anonymous], 2012, 15504, P1, DOI [DOI 10.1109/IEEESTD.2012.6375745, DOI 10.1109/IEEESTD.2012.6209381]
[2]   Fundamentals of semi-conductive systems for high voltage stress grading [J].
Conley, DJ ;
Frost, N .
Proceedings: Electrical Insulation Conference and Electrical Manufacturing Conference, 2005, :89-92
[3]   Low-frequency dielectric response of epoxy-mica insulated generator bars during multi-stress aging [J].
David, Eric ;
Lamarre, Laurent .
IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2007, 14 (01) :212-226
[4]   Dielectric response studies on insulating system of high voltage rotating machines [J].
Farahani, M ;
Borsi, H ;
Gockenbach, E .
IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2006, 13 (02) :383-393
[5]  
IEEE, 2002, IEEE STANDARD VOLTAG, DOI [10.1109/ieeestd.2003.94234, DOI 10.1109/IEEESTD.2003.94234]
[6]  
Lachance-Savard M., 2024, Master's thesis
[7]   Measured and Modeled Capacitance, Loss and Harmonics in Stator Insulation with Nonlinear Stress Control [J].
Taylor, N. .
IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2015, 22 (06) :3133-3145
[8]  
Taylor N., 2010, Taylor PHD thesis