Determination of optimal air supply form on sludge convective drying process: A CFD-DEM study

被引:0
作者
Li, Gong [1 ,2 ,3 ]
Zhang, Hao [1 ,4 ]
Ye, Xinglian [5 ]
Su, Yinbiao [5 ]
Yu, Aibing [2 ,3 ]
Wang, Yuelei [6 ]
Zhou, Zongyan [6 ]
机构
[1] Southeast Univ, Sch Energy & Environm, Key Lab Energy Thermal Convers & Control, Minist Educ, Nanjing 210096, Jiangsu, Peoples R China
[2] Southeast Univ, Monash Univ, Joint Res Inst, Suzhou 215123, Jiangsu, Peoples R China
[3] Monash Univ, Dept Chem & Biol Engn, ARC Res Hub Smart Proc Design & Control, Clayton, Vic 3800, Australia
[4] Northeastern Univ, Sch Met, Key Lab Ecol Met Multimet Mineral, Minist Educ, Shenyang 110819, Liaoning, Peoples R China
[5] Fujian Longking Co Ltd, Longyan 364000, Fujian, Peoples R China
[6] Jiangxi Univ Sci & Technol, Jiangxi Prov Key Lab Simulat & Modelling Particula, Nanchang 330013, Jiangxi, Peoples R China
关键词
Sludge; Convective drying; Air supply; Dryer; CFD-DEM; Numerical simulation; DISCRETE PARTICLE SIMULATION; PARTICULATE SYSTEMS; HEAT-TRANSFER; MODEL; BEHAVIOR; DESIGN;
D O I
10.1016/j.powtec.2024.120052
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Convective thermal drying is usually used in sludge dryers, and the air supply forms significantly affect the sludge drying efficiency. In this work, the drying process of multi-layered sludge is numerically simulated using a coupled computational fluid dynamics-discrete element method (CFD-DEM) approach. Better than our previous work, the current CFD-DEM model further considers the dynamic process of humidity within the flow field. Firstly, the CFD-DEM model is validated based on the mechanistic experimental data. Then, extensive numerical simulations are carried out to investigate the two-layered sludge drying process in the dryer, and the effects of two conventional air supply forms (Top-to-Bottom and Bottom-to-Top) as well as a novel air supply form (Side assist) on the two-phase flow system are discussed. The simulation results provide in detail the dynamic processes of momentum, heat and mass (moisture) in the convective drying system under different working conditions. Following recommendations are presented to facilitate the operation of the dryer: Bottom-to-Top is better for sludge drying and tends to utilize less heat from the heat source compared to the Top-to-Bottom. The drying efficiency can be further improved by supplying the Side-assist with an optimal flow ratio of side-wind to bottomwind. Numerical results show that the optimal flow ratio is related to the total air volume, the deflection angle and the side-wind temperature. The present study reveals in depth the impact mechanism of the air supply form on the convective thermal drying process of sludge, which contributes to the design and optimization of highefficiency dryers.
引用
收藏
页数:23
相关论文
共 47 条
[31]   Computational Fluid Dynamics in Drying Process Modelling-a Technical Review [J].
Ramachandran, Rani Puthukulangara ;
Akbarzadeh, Mohsen ;
Paliwal, Jitendra ;
Cenkowski, Stefan .
FOOD AND BIOPROCESS TECHNOLOGY, 2018, 11 (02) :271-292
[32]   Recent advances in sludge dewatering and drying technology [J].
Rao, Binqi ;
Wang, Gongqin ;
Xu, Peng .
DRYING TECHNOLOGY, 2022, 40 (15) :3049-3063
[33]  
Rocky E., 2021, Release 2021 R2, DEM technical manual
[34]  
Rocky E., 2021, Release 2021 R2, DEM-CFD Coupling Technical Manual
[35]  
Rocky E., 2021, Release 2021 R2, CFD-Coupled Particle Drying Module Help
[36]   Coupled DEM-CFD simulation of drying wood chips in a rotary drum - Baffle design and model reduction [J].
Scherer, Viktor ;
Moennigmann, Martin ;
Berner, Marc Oliver ;
Sudbrock, Florian .
FUEL, 2016, 184 :896-904
[37]   A NEW KAPPA-EPSILON EDDY VISCOSITY MODEL FOR HIGH REYNOLDS-NUMBER TURBULENT FLOWS [J].
SHIH, TH ;
LIOU, WW ;
SHABBIR, A ;
YANG, ZG ;
ZHU, J .
COMPUTERS & FLUIDS, 1995, 24 (03) :227-238
[38]   A novel method for convective drying rate estimation in a deep fixed porous material bed [J].
Skarbalius, Gediminas ;
Dziugys, Algis ;
Misiulis, Edgaras ;
Navakas, Robertas .
POWDER TECHNOLOGY, 2022, 404
[39]   Improved 3-D temperature uniformity in a laboratory drying oven based on experimentally validated CFD computations [J].
Smolka, Jacek ;
Nowak, Andrzej J. ;
Rybarz, Dawid .
JOURNAL OF FOOD ENGINEERING, 2010, 97 (03) :373-383
[40]   Cluster patterns in circulating fluidized beds predicted by numerical simulation (discrete particle model versus two-fluid model) [J].
Tsuji, Y ;
Tanaka, T ;
Yonemura, S .
POWDER TECHNOLOGY, 1998, 95 (03) :254-264