Association between high-density mapping of atypical atrial flutter, clinical outcomes and healthcare utilization

被引:1
作者
Sink, Joshua [1 ]
Culler, Kasen [1 ]
Uppalapati, Lakshmi [2 ]
Lancki, Nicola [3 ]
Peigh, Graham [4 ]
Lohrmann, Graham [4 ]
Elsayed, Mahmoud [4 ]
Carneiro, Herman [4 ]
Baman, Jayson [4 ]
Pfenniger, Anna [4 ]
Patil, Kaustubha D. [4 ]
Verma, Nishant [4 ]
Arora, Rishi [4 ]
Kim, Susan S. [4 ]
Chicos, Alexandru B. [4 ]
Lin, Albert C. [4 ]
Knight, Bradley P. [4 ]
Passman, Rod S. [4 ]
机构
[1] Northwestern Univ, Dept Internal Med, Chicago, IL USA
[2] Baylor Univ, Dept Internal Med, Houston, TX USA
[3] Northwestern Univ, Dept Preventat Med, Chicago, IL USA
[4] Northwestern Univ, Div Cardiol, Chicago, IL 60208 USA
关键词
atypical atrial flutter; healthcare utilization; high density mapping;
D O I
10.1111/jce.16355
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BackgroundSuccess of atypical atrial flutter (AAFL) ablation has historically been limited by difficulty mapping the complex re-entrant circuits involved. While high-density (HD) mapping has become commonplace in clinical practice, there are limited data on outcomes of HD versus non-HD mapping for AAFL ablation.ObjectiveTo compare clinical outcomes and healthcare utilization using HD mapping versus non-HD mapping for AAFL ablation.MethodsRetrospective analysis of all AAFL procedures between 2005 and 2022 at an academic medical center was conducted. Procedures utilizing a 16-electrode HD Grid catheter and Precision mapping system were compared to procedures using prior generation 10-20 electrode spiral catheters and the Velocity system (Abbott, IL). Cox regression models and Poisson regression models were utilized to examine procedural and healthcare utilization outcomes. Models were adjusted for left ventricular ejection fraction, CHA2DS2-VASc, and history of prior ablation.ResultsThere were 108 patients (62% HD mapping) included in the analysis. Baseline clinical characteristics were similar between groups. Use of HD mapping was associated with a higher rate of AAFL circuit delineation (92.5% vs. 76%; p = .014) and a greater adjusted procedure success rate, defined as non-inducibility at procedure end, (aRR (95% CI) 1.26 (1.02-1.55) p = .035) than non-HD mapping. HD mapping was also associated with a lower rate of ED visits (aIRR (95% CI) 0.32 (0.14-0.71); p = .007) and hospitalizations (aIRR (95% CI) 0.32 (0.14-0.68); p = .004) for AF/AFL/HF through 1 year. While there was a lower rate of recurrent AFL through 1 year among HD mapping cases (aHR (95% CI) 0.60 (0.31-1.16) p = .13), statistical significance was not met likely due to the low sample size and higher rate of ambulatory rhythm monitoring in the HD group (61% vs. 39%, p = .025).ConclusionCompared to non-HD mapping, AAFL ablation with HD mapping is associated with improvements in the ability to define the AAFL circuit, greater procedural success, and a reduction in the number of ED visits and hospitalization for AF/AFL/HF. Comparison of ED visits and hospitalizations for AF/AFL/HF through 1 year for HD versus non-HD mapping of atypical atrial flutter image
引用
收藏
页码:1779 / 1785
页数:7
相关论文
共 13 条
  • [1] High-density versus low-density mapping in ablation of atypical atrial flutter
    Balt, J. C.
    Klaver, M. N.
    Mahmoodi, B. K.
    van Dijk, V. F.
    Wijffels, M. C. E. F.
    Boersma, L. V. A.
    [J]. JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2021, 62 (03) : 587 - 599
  • [2] A Comprehensive Evaluation of Rhythm Monitoring Strategies for the Detection of Atrial Fibrillation Recurrence Insights From 647 Continuously Monitored Patients and Implications for Monitoring After Therapeutic Interventions
    Charitos, Efstratios I.
    Stierle, Ulrich
    Ziegler, Paul D.
    Baldewig, Malte
    Robinson, Derek R.
    Sievers, Hans-Hinrich
    Hanke, Thorsten
    [J]. CIRCULATION, 2012, 126 (07) : 806 - 814
  • [3] Cosío FG, 2017, ARRHYTH ELECTROPHYSI, V6, P55, DOI [10.15420/aer.2017:5:2, 10.15420/aer.2017.5.2]
  • [4] Crandall Brian, 2020, J Atr Fibrillation, V13, P2414, DOI 10.4022/jafib.2414
  • [5] High-resolution, live, directional mapping
    Deno, D. Curtis
    Bhaskaran, Abhishek
    Morgan, Dennis J.
    Goksu, Fikri
    Batman, Katherine
    Olson, Gregory K.
    Magtibay, Karl
    Nayyar, Sachin
    Porta-Sanchez, Andreu
    Laflamme, Michael A.
    Masse, Stephane
    Aukhojee, Prashant
    Nair, Krishnakumar
    Nanthakumar, Kumaraswamy
    [J]. HEART RHYTHM, 2020, 17 (09) : 1621 - 1628
  • [6] Clinical impact of high-density mapping on the acute and long term outcome of atypical atrial flutter ablations
    Di Cori, Andrea
    Mazzocchetti, Lorenzo
    Parollo, Matteo
    Giannotti, Mario
    Canu, Antonio
    Barletta, Valentina
    della Volpe, Salvatore
    De Lucia, Raffaele
    Viani, Stefano
    Segreti, Luca
    Soldati, Ezio
    Zucchelli, Giulio
    Bongiorni, Maria Grazia
    [J]. JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2024, 67 (01) : 43 - 51
  • [7] Characterization of high-density mapping in catheter ablation for persistent atrial fibrillation: results from the Advisor™ HD Grid Mapping Catheter Observational study
    Fiedler, Lukas
    Roca, Ivo
    Lorgat, Faizel
    Lacotte, Jerome
    Haqqani, Haris
    Jesser, Emily
    Williams, Christopher
    Roithinger, Franz Xaver
    Steven, Daniel
    [J]. JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2022, 66 (6) : 1411 - 1421
  • [8] Atypical atrial flutter
    Garan, Hasan
    [J]. HEART RHYTHM, 2008, 5 (04) : 618 - 621
  • [9] Atypical atrial flutter: review of mechanisms, advances in mapping and ablation outcomes
    Ko, Nway Le Ko
    Sriramoju, Anil
    Khetarpal, Banveet Kaur
    Srivathsan, Komandoor
    [J]. CURRENT OPINION IN CARDIOLOGY, 2022, 37 (01) : 36 - 45
  • [10] Left atrial voltage mapping with a direction-independent grid catheter: Comparison with a conventional circular mapping catheter
    Masuda, Masaharu
    Asai, Mitsutoshi
    Iida, Osamu
    Okamoto, Shin
    Ishihara, Takayuki
    Nanto, Kiyonori
    Kanda, Takashi
    Tsujimura, Takuya
    Matsuda, Yasuhiro
    Okuno, Shota
    Hata, Yosuke
    Mano, Toshiaki
    [J]. JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2019, 30 (12) : 2834 - 2840