Quantitation of propofol metabolites by LC-MS/MS demonstrating long detection window for urine drug monitoring

被引:3
作者
Rosano, Thomas G. [1 ,2 ]
Wood, Michelle [3 ]
Scholz, Kiley L. [1 ]
Whitely, Kiera [4 ]
Kim, Nathaniel [4 ]
Ehlers, Melissa [4 ]
机构
[1] Natl Toxicol Ctr, Clin & Forens Toxicol Serv, Albany, NY 12208 USA
[2] Albany Med Coll, Dept Pathol & Lab Med, Albany, NY 12208 USA
[3] Waters Corp, Toxicol Res & Dev Div, Wilmslow, England
[4] Albany Med Coll, Dept Anesthesiol, Albany, NY 12208 USA
来源
JOURNAL OF MASS SPECTROMETRY AND ADVANCES IN THE CLINICAL LAB | 2024年 / 32卷
关键词
Propofol; Propofol metabolites; Urine drug monitoring; Liquidchromatography-tandem mass; spectrometry; LIQUID-CHROMATOGRAPHY; IN-VITRO; GLUCURONIDE; LIVER; HAIR; PHARMACOKINETICS; DISPOSITION; MICROSOMES; INDUCTION; SEDATION;
D O I
10.1016/j.jmsacl.2024.04.001
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Introduction: Chromatographic methods for analysis of propofol and its metabolites have been widely used in pharmacokinetic studies of propofol distribution, metabolism, and clearance. Application of chromatographic methods is also needed in clinical and forensic laboratories for detecting and monitoring propofol misuse. Objective: We report a method for sensitive analysis of propofol, propofol 1-glucuronide (PG), 4-hydroxypropofol 1-glucuronide (1-QG), 4-hydroxypropofol 4-glucuronide (4-QG) and 4-hydroxypropofol 4-sulfate (4-QS) in urine by LC-MS/MS analysis. The method employs a simple dilute-and-analyze sample preparation with stable isotope internal standardization. Results: Validation studies demonstrate a linear calibration model (100-10,000 ng/mL), with dilution integrity verified for the extended range of concentrations experienced in propofol use. Criteria-based validation was achieved, including an average coefficient of variation of 6.5 % and a percent bias of -4.2 ng/mL. The method was evaluated in 12 surgical patients, with monitoring periods lasting up to 30 days following intravenous propofol administrations of 100-3000 mg on the day of surgery. While the concentration ratio of PG to 4-hydroxy propofol metabolite decreased significantly in the days following surgery, PG maintained the highest concentration in all specimens. Both PG and 1-QG were detectable throughout the monitoring periods, including in a patient monitored for 30 days. Lower concentrations were determined for 4-QG and 4-QS, with evidence of detection up to 20 days. Propofol was not detectable in any urine specimens, thereby proving ineffective for identifying drug use. Conclusion: The validated method for quantifying propofol metabolites demonstrates its applicability for the sensitive detection of propofol misuse over a long window of drug-use detection.
引用
收藏
页码:60 / 67
页数:8
相关论文
共 50 条
[21]   Developing LC-MS/MS methods to quantify rivaroxabanin human plasma and urine: Application to therapeutic drug monitoring [J].
Zheng, Xin ;
Chen, Chen ;
Gao, Huitao ;
Sun, Xuefeng ;
Zhang, Yanbao ;
Shi, Juhong ;
Han, Xiaohong .
BIOMEDICAL CHROMATOGRAPHY, 2022, 36 (05)
[22]   Determination of six pterins in urine by LC-MS/MS [J].
Allegri, Gabriella ;
Bezerra Costa Netto, Heleno Jose ;
Lopes Ferreira Gomes, Luiz Nelson ;
Costa de Oliveira, Maria Lucia ;
Scalco, Fernanda Bertao ;
de Aquino Neto, Francisco Radler .
BIOANALYSIS, 2012, 4 (14) :1739-1746
[23]   Quantitative determination of mycotoxins in urine by LC-MS/MS [J].
Ahn, J. ;
Kim, D. ;
Kim, H. ;
Jahng, K. -Y. .
FOOD ADDITIVES AND CONTAMINANTS PART A-CHEMISTRY ANALYSIS CONTROL EXPOSURE & RISK ASSESSMENT, 2010, 27 (12) :1674-1682
[24]   Determination of palonosetron in human urine by LC-MS/MS [J].
Wang, Yuanyuan ;
Wang, Yongqing ;
Zhang, Peipei ;
Lu, Zhihong ;
Gu, Ying ;
Ou, Ning .
BIOANALYSIS, 2011, 3 (12) :1337-1342
[25]   LC-MS/MS based detection and characterization of covalent glutathione modifications formed by reactive drug of abuse metabolites [J].
Gilliland, R. Allen ;
Moller, Carolina ;
DeCaprio, Anthony P. .
XENOBIOTICA, 2019, 49 (07) :778-790
[26]   Advances in the quantitation of therapeutic insulin analogues by LC-MS/MS [J].
Blackburn, Michael .
BIOANALYSIS, 2013, 5 (23) :2933-2946
[27]   Validation of an LC-MS/MS method for quantitation of fostemsavir in plasma [J].
Lolla, Siddhartha ;
Gubbiyappa, Kumar Shiva ;
Cheruku, Shankar ;
Bhikshapathi, D. V. R. N. .
JOURNAL OF PHARMACOLOGICAL AND TOXICOLOGICAL METHODS, 2023, 120
[28]   Quantitation of the anaesthetic xylazine in ovine plasma by LC-MS/MS [J].
Doran, Gregory S. ;
Bradbury, Leah A. .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2015, 997 :81-84
[29]   Current role of LC-MS in therapeutic drug monitoring [J].
Franck Saint-Marcoux ;
François-Ludovic Sauvage ;
Pierre Marquet .
Analytical and Bioanalytical Chemistry, 2007, 388 :1327-1349
[30]   Current role of LC-MS in therapeutic drug monitoring [J].
Saint-Marcoux, Franck ;
Sauvagge, Francois-Ludovic ;
Marquet, Pierre .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2007, 388 (07) :1327-1349