Assessment of some air pollutants in the Sanctuary of the Beata Vergine dei Miracoli (Saronno, Italy) and first evaluation of a new axial passive sampler for nitrogen dioxide

被引:1
作者
Ricciardi, Maria [1 ,2 ]
Sofia, Daniele [3 ]
Faggiano, Antonio [1 ,2 ]
Bergomi, Andrea [2 ,4 ]
Comite, Valeria [4 ]
Guglielmi, Vittoria [4 ]
Fermo, Paola [4 ]
Proto, Antonio [1 ,2 ]
Motta, Oriana [2 ,5 ]
机构
[1] Univ Salerno, Dept Chem & Biol, Via Giovanni Paolo II 132, I-84084 Fisciano, SA, Italy
[2] Consorzio Interuniv Nazl Sci & Tecnol Materiali IN, I-50121 Florence, Italy
[3] Univ Calabria, Dept Comp Modeling Elect & Syst Engn, Via P Bucci Edificio 42, I-87036 Arcavacata Di Rende, CS, Italy
[4] Univ Milan, Dept Chem, Via Golgi 19, I-20133 Milan, Italy
[5] Univ Salerno, Dept Med Surg & Dent, Via S Allende, I-84081 Baronissi, SA, Italy
关键词
Air pollutants; Passive sampling; Radial sampler; Axial sampler; Air quality; VOLATILE ORGANIC-COMPOUNDS; AMBIENT AIR; NO2; INDOOR; INCENSE; SO2; O-3; EXPOSURE; ANTWERP; WORKERS;
D O I
10.1016/j.microc.2024.110593
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In the present study the concentration of some air pollutants (nitrogen dioxide, sulphur dioxide, hydrogen sulphide, ammonia and BTEX, i.e. benzene, toluene, ethylbenzene and xylene) was monitored inside and outside the Sanctuary of the Beata Vergine dei Miracoli (Saronno, Italy) by passive air sampling (using radial samplers), during two sampling periods in 2022 (April 27-May 11 and May 11-May 25). Concurrently, particulate matter (PM10 and PM2.5) concentration was determined by using sensors based on laser scattering technology. Moreover, we took advantage of the location of this sanctuary (proximity to an air monitoring central unit) to evaluate the performance of a new axial-type sampler for nitrogen dioxide. Sulphur dioxide concentration was in the range 0.8-3.1 mu g/m(3), with outdoor values higher than indoor ones, whereas no detectable concentrations of hydrogen sulphide were found (<0.1 <mu>g/m(3)). A different trend was observed for ammonia, where indoor concentrations were higher than outdoor ones (3.6-5.5 vs 2.7-3.1 mu g/m(3)). Among BTEX, only for benzene statistical differences (p-value < 0.05) between the indoor and outdoor concentrations were found, suggesting additional indoor sources for this hydrocarbon. Toluene results as the most abundant among these hydrocarbons (1.7-2.3 <mu>g/m(3)) in outdoor environments, whereas, in indoor environments, benzene has the higher concentration (6-9 mu g/m(3)). The indoor concentrations of NO2 (15.4-22.2 mu g/m(3) for radial samplers and 48-60 mu g/m(3) for axial samplers) are not only much higher than the recommended limit values to guarantee proper conservation of artefacts (5 mu g/m(3)), but also close to the values for human health preservation (40 mu g/m(3)), suggesting the need of proper strategy to improve indoor air quality inside the Sanctuary. The preliminary results obtained for the new axial-type sampler for nitrogen dioxide are very encouraging, given the closeness of the obtained concentration data to those measured by monitoring central unit, even though further experiments will have to be carried out to validate this sampler.
引用
收藏
页数:11
相关论文
共 53 条
[1]  
[Anonymous], 2016, Basic Information about NO2
[2]  
[Anonymous], DECRETO LEGISLATIVO
[3]   Preliminary Air Quality and Microclimatic Conditions Study in the Santuario della Beata Vergine dei Miracoli in Saronno (VA) [J].
Bergomi, Andrea ;
Comite, Valeria ;
Guglielmi, Vittoria ;
Borelli, Mattia ;
Lombardi, Chiara Andrea ;
Bonomi, Roberto ;
Pironti, Concetta ;
Ricciardi, Maria ;
Proto, Antonio ;
Mariani, Carlo ;
Fermo, Paola .
MOLECULES, 2023, 28 (04)
[4]   Validation and field application of tailor-made nitrogen dioxide passive samplers [J].
Bootdee, S. ;
Chalemrom, P. ;
Chantara, S. .
INTERNATIONAL JOURNAL OF ENVIRONMENTAL SCIENCE AND TECHNOLOGY, 2012, 9 (03) :515-526
[5]   THE USE OF DIFFUSIVE SAMPLERS FOR MONITORING OF AMBIENT AIR [J].
BROWN, RH .
PURE AND APPLIED CHEMISTRY, 1993, 65 (08) :1859-1874
[6]   Development and validation of passive samplers for atmospheric monitoring of SO2, NO2, O3 and H2S in tropical areas [J].
Campos, Vania P. ;
Cruz, Licia P. S. ;
Godoi, Ricardo H. M. ;
Godoi, Ana Flavia L. ;
Tavares, Tania M. .
MICROCHEMICAL JOURNAL, 2010, 96 (01) :132-138
[7]   The Use of Passive Diffusion Tubes for Measuring Concentrations of Nitrogen Dioxide in Air [J].
Cape, J. N. .
CRITICAL REVIEWS IN ANALYTICAL CHEMISTRY, 2009, 39 (04) :289-310
[8]   Assessment of the impact of the vehicular traffic on BTEX concentration in ring roads in urban areas of Bari (Italy) [J].
Caselli, Maurizio ;
de Gennaro, Gianluigi ;
Marzocca, Annalisa ;
Trizio, Livia ;
Tutino, Maria .
CHEMOSPHERE, 2010, 81 (03) :306-311
[9]   Concentrations, sources, and health risk associated with exposure to BTEX at ten sites located in an urban-industrial area in the Bajio Region, Mexico [J].
Ceron-Breton, Julia Griselda ;
Ceron Breton, Rosa Maria ;
Kahl, Jonathan D. W. ;
Sanchez Rico, Gisela ;
Carranco Lozada, Simon Eduardo ;
de la Luz Espinosa Fuentes, Maria ;
Uc Chi, Martha Patricia .
AIR QUALITY ATMOSPHERE AND HEALTH, 2021, 14 (05) :741-761
[10]   Measurement of volatile organic compounds (VOCs) in libraries and archives in Florence (Italy) [J].
Cincinelli, A. ;
Martellini, T. ;
Amore, A. ;
Dei, L. ;
Marrazza, G. ;
Carretti, E. ;
Belosi, F. ;
Ravegnani, F. ;
Leva, P. .
SCIENCE OF THE TOTAL ENVIRONMENT, 2016, 572 :333-339