Meta-analysis of transjugular intrahepatic portosystemic shunt creation with or without intravascular ultrasound guidance

被引:2
作者
Yu, Qian [1 ]
Ahmed, Osman [1 ]
Gutti, Subhash [2 ]
Iyer, Deepak [2 ]
Kwak, Daniel [1 ]
Ahmed, Syed Samaduddin [3 ]
Said, Adam [4 ]
Angle, J. Fritz [5 ]
Navuluri, Rakesh [1 ]
Lorenz, Jonathan M. [1 ]
Patel, Mikin [1 ]
机构
[1] Univ Chicago, Dept Radiol, Vasc & Intervent Radiol, Med Ctr, 5841 S Maryland Ave, Chicago, IL 60637 USA
[2] George Washington Univ, Sch Med & Hlth Sci, Washington, DC 20007 USA
[3] Midwestern Univ Chicago, Coll Osteopath Med, Chicago, IL 60515 USA
[4] Univ Illinois, Champaign, IL 61820 USA
[5] Univ Virginia Hlth Syst, Vasc & Intervent Radiol, Charlottesville, VA USA
关键词
cirrhosis; intravascular ultrasound; portal hypertension; transjugular intrahepatic portosystemic shunt; PORTAL-VEIN RECANALIZATION; TIPS; PUNCTURE; ACCESS;
D O I
10.1093/bjr/tqae074
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective To conduct a meta-analysis to assess the efficacy of intravascular ultrasound (IVUS) during transjugular intrahepatic portosystemic shunt (TIPS) creation. Methods MEDLINE and Embase databases were queried until July 2022 for comparative studies reporting procedure metrics for TIPS creation with or without IVUS guidance. Meta-analysis was performed with random-effects modelling for total procedural time, time to portal venous access, fluoroscopy time, iodinated contrast volume use, air kerma, dose area product, and number of needle passes. Intraoperative procedure-related complications were also reviewed. Results Of 95 unique records initially identified, 6 were eligible for inclusion. A total of 194 and 240 patients underwent TIPS with and without IVUS guidance. Pooled analyses indicated that IVUS guidance was associated with reduced total procedure time (SMD -0.76 [95% CI -1.02, -0.50] P < .001), time to portal venous access (SMD -0.41 [95% CI -0.67, -0.15] P = .002), fluoroscopy time (SMD, -0.54 [95% CI -1.02, -0.07]; P = .002), contrast volume use (SMD, -0.89 [95% CI -1.16, -0.63]; P < .001), air kerma (SMD, -0.75 [95% CI -1.11, -0.38]; P < .001) and dose area product (SMD, -0.98 [95% CI -1.77, -0.20]; P = .013). A total of 4.2 and 7.8 needle passes were required in the IVUS and non-IVUS group, respectively (SMD, -0.60 [95% CI -1.42, 0.21]; P = .134). Pooled complication rates were 15.2% (12/79) and 21.4% (28/131), respectively. Conclusion IVUS guidance during TIPS creation improves procedural metrics including procedural time, contrast usage, and radiation exposure. Advances in Knowledge (1) The use of IVUS during TIPS is associated with shorter procedural time, lower contrast usage, and radiation exposure. (2)The use of IVUS is not associated with higher complication rates.
引用
收藏
页码:1112 / 1117
页数:6
相关论文
共 31 条
[1]   Transjugular Intrahepatic Portosystemic Shunt Placement: Entering the Era of Controlled Expansion [J].
Ahmed, Osman ;
Yu, Qian .
CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2023, 46 (6) :823-824
[2]   Inadvertent Hepatic Arterial Cannulation during Transjugular Intrahepatic Portosystemic Shunt Creation [J].
Arunachalam, Venkata Subbaih ;
Valakkada, Jineesh ;
Ayyappan, Anoop .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2024, 35 (03) :483-484
[3]   Quality Improvement Guidelines for Transjugular lntrahepatic Portosystemic Shunts [J].
Dariushnia, Sean R. ;
Haskal, Ziv J. ;
Midia, Mehran ;
Martin, Louis G. ;
Walker, T. Gregory ;
Kalva, Sanjeeva P. ;
Clark, Timothy W. I. ;
Ganguli, Suvranu ;
Krishnamurthy, Venkataramu ;
Saiter, Cindy K. ;
Nikolic, Boris .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2016, 27 (01) :1-7
[4]   Intravascular Ultrasound Guidance for TIPS Procedures: A Review [J].
Dastmalchian, Sara ;
Aryafar, Hamed ;
Tavri, Sidhartha .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2022, 219 (04) :634-646
[5]   Anatomical Variations of Hepatic Veins: Three-Dimensional Computed Tomography Scans of 200 Subjects [J].
Fang, Chi-Hua ;
You, Jin-Hua ;
Lau, Wan Yee ;
Lai, Eric C. H. ;
Fan, Ying-Fang ;
Zhong, Shi-Zhen ;
Li, Ke-Xiao ;
Chen, Zhi-Xiang ;
Su, Zhong-He ;
Bao, Su-Su .
WORLD JOURNAL OF SURGERY, 2012, 36 (01) :120-124
[6]   Transjugular Intrahepatic Portosystemic Shunt Creation Using Intravascular Ultrasound Guidance [J].
Farsad, Khashayar ;
Fuss, Cristina ;
Kolbeck, Kenneth J. ;
Barton, Robert E. ;
Lakin, Paul C. ;
Keller, Frederick S. ;
Kaufman, John A. .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2012, 23 (12) :1594-1602
[7]   Intravascular US-Guided Portal Vein Access: Improved Procedural Metrics during TIPS Creation [J].
Gipson, Matthew G. ;
Smith, Mitchell T. ;
Durham, Janette D. ;
Brown, Anthony ;
Johnson, Thor ;
Ray, Charles E., Jr. ;
Gupta, Rajan K. ;
Kondo, Kimi L. ;
Rochon, Paul J. ;
Ryu, Robert K. .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2016, 27 (08) :1140-1147
[8]   Portal Vein Recanalization-Transjugular Intrahepatic Portosystemic Shunt Using the Transsplenic Approach to Achieve Transplant Candidacy in Patients with Chronic Portal Vein Thrombosis [J].
Habib, Ali ;
Desai, Kush ;
Hickey, Ryan ;
Thornburg, Bartley ;
Vouche, Michael ;
Vogelzang, Robert L. ;
Salem, Riad .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2015, 26 (04) :499-506
[9]  
Harman J T, 1992, J Vasc Interv Radiol, V3, P545, DOI 10.1016/S1051-0443(92)72010-7
[10]   Transjugular intrahepatic transcaval portosystemic shunt: The gun-sight approach [J].
Haskal, ZJ ;
Duszak, R ;
Furth, EE .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 1996, 7 (01) :139-142