Digital versus conventional complete dentures: A randomized, controlled, double-blinded crossover trial

被引:3
作者
Peroz, Simon [1 ]
Peroz, Ingrid [1 ]
Beuer, Florian [1 ]
von Stein-Lausnitz, Manja [1 ]
Sterzenbach, Guido [1 ]
机构
[1] Univ Med Berlin, Dept Prosthodont Geriatr Dent & Craniomandibular D, CC Dent & Craniofacial Sci 3, Charite, Campus Benjamin Franklin CBF,Assmannshauser Str 4-, D-14197 Berlin, Germany
关键词
ENGINEERED COMPLETE DENTURES; CAD/CAM; BASES;
D O I
10.1016/j.prosdent.2022.04.023
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. The Baltic Denture System provides a digital way to fabricate complete dentures in 2 visits. Conventional dentures using injection or compression molding require additional visits and complex laboratory procedures. However, how the fabrication method affects clinical outcomes is unclear. Purpose. The purpose of this clinical, randomized, controlled, double-blinded crossover trial was to evaluate the impact of the fabrication method (digital versus conventional production) of complete dentures on clinical outcomes. Material and methods. Sixteen participants received 2 pairs of new complete dentures, produced in a digital and a conventional workflow. Each complete denture was worn for an observation period of 3 months. The order of the dentures was randomized. The primary outcome was the clinical assessment of the dentures by a blinded examiner, including peripheral extension, cutout for buccal and labial frenula, denture extension, and denture thickness. Denture esthetics were evaluated by the midline, position of anterior teeth, buccal corridor, and smile arc, and occlusal relationships were evaluated by the vertical dimension, sagittal relation, the Camper plane, and occlusion. In addition, the retention of maxillary and mandibular dentures and phonetics was evaluated. Differences between the prostheses were statistically analyzed with the McNemar test (a=.05). Results. The borders of the digital dentures were significantly more often overextended at the time of insertion (P=.021), reducing the retention of the digital dentures, especially the maxillary dentures (P=.016). The borders of the dentures could be corrected so that after 2 weeks and 3 months, no significant differences could be seen between digital dentures and conventional dentures. Conclusions. The fabrication method has a significant influence only on the dimension of the denture border. It was significantly more often overextended in digital dentures and impaired retention, especially of the maxillary dentures, at the time of insertion. As this parameter is correctable, no significant clinical differences could be observed over the observation time of 3 months between digital dentures and conventional dentures. (J Prosthet Dent 2024;132:132-8)
引用
收藏
页码:132 / 138
页数:7
相关论文
共 22 条
  • [11] An update on computer-engineered complete dentures: A systematic review on clinical outcomes
    Kattadiyil, Mathew T.
    AlHelal, Abdulaziz
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2017, 117 (04) : 478 - 485
  • [12] Comparison of treatment outcomes in digital and conventional complete removable dental prosthesis fabrications in a predoctoral setting
    Kattadiyil, Mathew T.
    Jekki, Rami
    Goodacre, Charles J.
    Baba, Nadim Z.
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2015, 114 (06) : 818 - 825
  • [13] Comparing accuracy of denture bases fabricated by injection molding, CAD/CAM milling, and rapid prototyping method
    Lee, Suji
    Hong, Seoung-Jin
    Paek, Janghyun
    Pae, Ahran
    Kwon, Kung-Rock
    Noh, Kwantae
    [J]. JOURNAL OF ADVANCED PROSTHODONTICS, 2019, 11 (01) : 55 - 64
  • [14] Digital versus conventional complete dentures: A randomized, controlled, blinded study
    Peroz, Simon
    Peroz, Ingrid
    Beuer, Florian
    Sterzenbach, Guido
    von Stein-Lausnitz, Manja
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2022, 128 (05) : 956 - 963
  • [15] Clinical performance of computer-engineered complete dentures: a retrospective pilot study
    Schlenz, Maximiliane Amelie
    Schmidt, Alexander
    Woestmann, Bernd
    Rehmann, Peter
    [J]. QUINTESSENCE INTERNATIONAL, 2019, 50 (09): : 706 - 711
  • [16] CAD/CAM milled removable complete dentures: time and cost estimation study
    Srinivasan, Murali
    Schimmel, Martin
    Naharro, Manuel
    O'Neill, Ciaran
    McKenna, Gerald
    Mueller, Frauke
    [J]. JOURNAL OF DENTISTRY, 2019, 80 : 75 - 79
  • [17] Influence of CAD/CAM fabrication on denture surface properties
    Steinmassl, O.
    Dumfahrt, H.
    Grunert, I.
    Steinmassl, P. -A.
    [J]. JOURNAL OF ORAL REHABILITATION, 2018, 45 (05) : 406 - 413
  • [18] CAD/CAM produces dentures with improved fit
    Steinmassl, Otto
    Dumfahrt, Herbert
    Grunert, Ingrid
    Steinmassl, Patricia-Anca
    [J]. CLINICAL ORAL INVESTIGATIONS, 2018, 22 (08) : 2829 - 2835
  • [19] In Vitro Analysis of the Fracture Resistance of CAD/CAM Denture Base Resins
    Steinmassl, Otto
    Offermanns, Vincent
    Stoeckl, Wolfgang
    Dumfahrt, Herbert
    Grunert, Ingrid
    Steinmassl, Patricia-Anca
    [J]. MATERIALS, 2018, 11 (03):
  • [20] Do CAD/CAM dentures really release less monomer than conventional dentures?
    Steinmassl, Patricia-Anca
    Wiedemair, Verena
    Huck, Christian
    Klaunzer, Florian
    Steinmassl, Otto
    Grunert, Ingrid
    Dumfahrt, Herbert