Experimental Investigation of the Effect of Conductor Temperature on Corona Performance in Overhead Transmission Lines

被引:1
作者
Ilunga, Kayumba G. [1 ]
Swanson, Andrew G. [1 ]
Ijumba, Nelson Mutatina [2 ]
Stephen, Robert [1 ]
机构
[1] Univ KwaZulu Natal, Dept Elect Elect & Comp Engn, ZA-4041 Durban, South Africa
[2] Univ Rwanda, African Ctr Excellence Energy Sustainable Dev, Kigali, Rwanda
来源
IEEE ACCESS | 2024年 / 12卷
关键词
Corona; Conductors; Discharges (electric); Temperature measurement; Plasma temperature; Ionization; Transmission line measurements; Voltage control; Conductor temperature; corona discharge; inception voltage; ionization radius; POSITIVE DC CORONA; ELECTROSTATIC PRECIPITATOR; DISCHARGE; CONFIGURATION; AIR; MODEL;
D O I
10.1109/ACCESS.2024.3451980
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
The maximum conductor temperature regulates the maximum amount of power that overhead lines can transmit. Excessive line sag and accelerated conductor ageing may occur if this maximum temperature is exceeded. This is particularly true for the most popular steel-reinforced conductors or aluminium anneals, in which high temperatures can cause grease, which is used to prevent corrosion from seeping. High-temperature low-sag conductors have been developed to increase current carrying capacity. In addition to the temperature constraint, overhead transmission lines largely depend on the corona discharge performance. This paper presents experimental results on the investigation of corona performance due to conductor temperature. An experimental configuration that uses a 10 kVA power transformer in cascade with a 10 kVA high current low voltage transformer both connected to the conductor in the corona cage was successfully developed. This configuration allows for heating the conductor while connected to the high voltage and allows for measuring corona current using the screened electrode method of corona cage. The results indicate an increase in corona current with rising conductor temperature, accompanied by a 25% to 32% decrease in inception voltage. The primary factors contributing to these trends were identified as relative air density and the Townsend coefficient. A temperature model incorporating the ionization region was developed to calculate the relative air density accurately. Additionally, To account for the effect of conductor temperature, the well-known surface inception field strength formula proposed by Peek was refined through optimization. Comparisons between the refined Peek's formula and the measured results demonstrated successful alignment. This research enhances our understanding of corona performance with conductor temperature, providing valuable insights for optimizing transmission line design and operation.
引用
收藏
页码:122114 / 122125
页数:12
相关论文
共 50 条
  • [21] Electromagnetic transients in overhead lines considering frequency dependence and corona effect via the method of characteristics
    Ramírez, A
    Naredo, JL
    Moreno, P
    Guardado, JL
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2001, 23 (03) : 179 - 188
  • [22] A Temperature Dependent Power Flow Model Considering Overhead Transmission Line Conductor Thermal Inertia Characteristics
    Ngoko, Bonface
    Sugihara, Hideharu
    Funaki, Tsuyoshi
    2019 IEEE INTERNATIONAL CONFERENCE ON ENVIRONMENT AND ELECTRICAL ENGINEERING AND 2019 IEEE INDUSTRIAL AND COMMERCIAL POWER SYSTEMS EUROPE (EEEIC / I&CPS EUROPE), 2019,
  • [23] Experimental investigation on correlation of corona-induced vibration and audible noise from DC conductor
    Li, Xuebao
    Cui, Xiang
    Lu, Tiebing
    Wang, Donglai
    Peng, Renhua
    Bian, Xingming
    HIGH VOLTAGE, 2016, 1 (03): : 115 - 121
  • [25] Assessment of Lightning Shielding Performance of Double-Circuit UHV Overhead Transmission Lines
    He, Hengxin
    He, Junjia
    Xie, ShiJun
    Yao, Shuai
    Zhang, Dandan
    Dong, Manling
    IEEE POWER AND ENERGY SOCIETY GENERAL MEETING 2010, 2010,
  • [26] Corona discharge effect on frequency electric field distribution for AC transmission lines
    Zhou, Yusheng
    An, Zhengzhou
    Liu, Rangjiao
    Peng, Pai
    Gao, Yunlong
    Xiong, Jie
    MODERN COMPUTER SCIENCE AND APPLICATIONS (MCSA 2016), 2016, : 169 - 174
  • [27] Experimental Study on Ultrasonic Detection Method of Ice Thickness for 10 kV Overhead Transmission Lines
    Yang, Lin
    Chen, Jie
    Hao, Yanpeng
    Li, Licheng
    Lin, Xinhao
    Yu, Lei
    Li, Yue
    Yuan, Zhiyong
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2023, 72
  • [28] Modified field-to-line coupling model for simulating the corona effect on the lightning induced voltages of multi-conductor transmission lines over a lossy ground
    Liu, Xin
    Yang, Jiawei
    Liang, Guishu
    Wang, Litong
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2017, 11 (07) : 1865 - 1876
  • [29] Application of Nano Coating to ACSR conductor for the Protection of Transmission lines against Solar Storms, Surface Flashovers, Corona and Over voltages
    Selvaraj, D. Edison
    Mohanadasse, K.
    Sugumaran, C. Pugazhendhi
    Vijayaraj, R.
    JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY, 2015, 10 (05) : 2070 - 2076
  • [30] Effect of line length on the radiated electromagnetic interference due to corona on HV transmission lines
    Nayak, SK
    Thomas, MJ
    IPEC 2003: Proceedings of the 6th International Power Engineering Conference, Vols 1 and 2, 2003, : 264 - 269