Seasonal COP of a residential magnetocaloric heat pump based on MnFePSi

被引:2
作者
Quijano, Diego Pineda [1 ,2 ]
Lima, Beatriz Fonseca [3 ]
Ferreira, Carlos Infante [2 ]
Bruck, Ekkes [1 ]
机构
[1] Delft Univ Technol, Fundamental Aspects Mat & Energy, Dept Radiat Sci & Technol, Mekelweg 15, NL-2629 JB Delft, Netherlands
[2] Delft Univ Technol, Proc & Energy Lab, Leeghwater Str 39, NL-2628 CB Delft, Netherlands
[3] Univ Porto, Fac Engn, Rua Dr Roberto Frias,S N, P-4200465 Porto, Portugal
关键词
Magnetocaloric heat pump; Seasonal COP; Layered AMR; MnFePSi; Numerical simulation; ACTIVE MAGNETIC REGENERATOR; THERMODYNAMIC CYCLES; FLUID-FLOW; PERFORMANCE; INTEGRATION;
D O I
10.1016/j.ijrefrig.2024.04.014
中图分类号
O414.1 [热力学];
学科分类号
摘要
The performance of a magnetocaloric heat pump (MCHP) consisting of active magnetocaloric regenerators (AMR) of 12 layers of MnFePSi magnetocaloric materials (MCM) with a linear distribution of Curie temperatures was investigated using a 1D numerical model. The model predicted the heating power and coefficient of performance (COP) of the AMR for a fixed temperature span of 27 K, between 281 K and 308 K, and variable flow rate and AMR cycle frequency. A maximum applied magnetic field strength of 1 . 4 T was used. A wellinsulated house with a maximum heating power demand of 3 kW (under quasi steady state conditions) was considered. Ambient temperature in The Netherlands was taken as a reference for the estimation of the seasonal heating power demand. Without optimizing the design of the AMR, the model predicts a maximum single -AMR heating power equal to 43 . 5 W when the AMR operates at 3 Hz and 3 L min -1 , and a maximum COP equal to 5.8 when it operates at 1 . 5 Hz and 1 L min -1 Considering the maximum heating power of a single AMR, approximately 69 AMRs are needed to provide the design heating power demand of the house. It was found that it is possible to achieve an AMR seasonal COP of 5.6 by continuously adjusting the flow rate and frequency of operation of the MCHP along with the ON/OFF switching of some groups of AMRs in order to adjust the heating power of the MCHP to the heating power demand of the house.
引用
收藏
页码:38 / 48
页数:11
相关论文
共 50 条
[21]   Thermal characteristics of a seasonal solar assisted heat pump heating system with an underground tank [J].
Huang, Haotian ;
Xiao, Yimin ;
Lin, Jianquan ;
Zhou, Tiecheng ;
Liu, Yanan ;
Zhao, Qian .
SUSTAINABLE CITIES AND SOCIETY, 2020, 53
[22]   Magnetocaloric heat circulator based on self-heat recuperation technology [J].
Kotani, Yui ;
Aziz, Muhammad ;
Kansha, Yasuki ;
Fushimi, Chihiro ;
Tsutsumi, Atsushi .
CHEMICAL ENGINEERING SCIENCE, 2013, 101 :5-12
[23]   Dynamic thermal analysis of a residential ground-source heat pump [J].
Yang, S. ;
Lee, S. B. .
SUSTAINABLE ENERGY TECHNOLOGIES AND ASSESSMENTS, 2020, 37
[24]   MILP design optimization of heat pump systems in German residential buildings [J].
Kruetzfeldt, Hannah ;
Vering, Christian ;
Mehrfeld, Philipp ;
Mueller, Dirk .
ENERGY AND BUILDINGS, 2021, 249
[25]   Low-temperature heat emission combined with seasonal thermal storage and heat pump [J].
Hesaraki, Arefeh ;
Haliovic, Armin ;
Holmberg, Sture .
SOLAR ENERGY, 2015, 119 :122-133
[26]   Simulation on Mutil-heat Sources Solar Heat Pump Used For Water and Residential Heating [J].
Yang, Lei ;
Zhang, Xiaosong .
6TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATING AND AIR CONDITIONING, VOLS I-III, PROCEEDINGS, 2009, :1919-1926
[27]   Evaluating heat pump system design methods towards a sustainable heat supply in residential buildings [J].
Vering, Christian ;
Maier, Laura ;
Breuer, Katharina ;
Kruetzfeldt, Hannah ;
Streblow, Rita ;
Mueller, Dirk .
APPLIED ENERGY, 2022, 308
[28]   Energy pile-based ground source heat pump system with seasonal solar energy storage [J].
Ma, Qijie ;
Fan, Jianhua ;
Liu, Hantao .
RENEWABLE ENERGY, 2023, 206 :1132-1146
[29]   Enhanced thermal performance of a magnetocaloric heat-pump prototype based on new morphology particles for energy-efficient refrigeration [J].
Lewandowski, Daniel ;
Mech, Rafal ;
Surma, Kacper .
Applied Thermal Engineering, 2025, 279
[30]   Modelling Heat Pumps with Variable EER and COP in EnergyPlus: A Case Study Applied to Ground Source and Heat Recovery Heat Pump Systems [J].
Priarone, Antonella ;
Silenzi, Federico ;
Fossa, Marco .
ENERGIES, 2020, 13 (04)