Seasonal COP of a residential magnetocaloric heat pump based on MnFePSi

被引:2
|
作者
Quijano, Diego Pineda [1 ,2 ]
Lima, Beatriz Fonseca [3 ]
Ferreira, Carlos Infante [2 ]
Bruck, Ekkes [1 ]
机构
[1] Delft Univ Technol, Fundamental Aspects Mat & Energy, Dept Radiat Sci & Technol, Mekelweg 15, NL-2629 JB Delft, Netherlands
[2] Delft Univ Technol, Proc & Energy Lab, Leeghwater Str 39, NL-2628 CB Delft, Netherlands
[3] Univ Porto, Fac Engn, Rua Dr Roberto Frias,S N, P-4200465 Porto, Portugal
关键词
Magnetocaloric heat pump; Seasonal COP; Layered AMR; MnFePSi; Numerical simulation; ACTIVE MAGNETIC REGENERATOR; THERMODYNAMIC CYCLES; FLUID-FLOW; PERFORMANCE; INTEGRATION;
D O I
10.1016/j.ijrefrig.2024.04.014
中图分类号
O414.1 [热力学];
学科分类号
摘要
The performance of a magnetocaloric heat pump (MCHP) consisting of active magnetocaloric regenerators (AMR) of 12 layers of MnFePSi magnetocaloric materials (MCM) with a linear distribution of Curie temperatures was investigated using a 1D numerical model. The model predicted the heating power and coefficient of performance (COP) of the AMR for a fixed temperature span of 27 K, between 281 K and 308 K, and variable flow rate and AMR cycle frequency. A maximum applied magnetic field strength of 1 . 4 T was used. A wellinsulated house with a maximum heating power demand of 3 kW (under quasi steady state conditions) was considered. Ambient temperature in The Netherlands was taken as a reference for the estimation of the seasonal heating power demand. Without optimizing the design of the AMR, the model predicts a maximum single -AMR heating power equal to 43 . 5 W when the AMR operates at 3 Hz and 3 L min -1 , and a maximum COP equal to 5.8 when it operates at 1 . 5 Hz and 1 L min -1 Considering the maximum heating power of a single AMR, approximately 69 AMRs are needed to provide the design heating power demand of the house. It was found that it is possible to achieve an AMR seasonal COP of 5.6 by continuously adjusting the flow rate and frequency of operation of the MCHP along with the ON/OFF switching of some groups of AMRs in order to adjust the heating power of the MCHP to the heating power demand of the house.
引用
收藏
页码:38 / 48
页数:11
相关论文
共 50 条
  • [1] Layering strategies for active magnetocaloric regenerators using MnFePSi for heat pump applications
    Quijano, Diego Pineda
    Ferreira, Carlos Infante
    Bruck, Ekkes
    APPLIED THERMAL ENGINEERING, 2023, 232
  • [2] Integration of a magnetocaloric heat pump in an energy flexible residential building
    Johra, Hicham
    Filonenko, Konstantin
    Heiselberg, Per
    Veje, Christian
    Dall'Olio, Stefano
    Engelbrecht, Kurt
    Bahl, Christian
    RENEWABLE ENERGY, 2019, 136 : 115 - 126
  • [3] Integration of a magnetocaloric heat pump in a low-energy residential building
    Johra, Hicham
    Filonenko, Konstantin
    Heiselberg, Per
    Veje, Christian
    Lei, Tian
    Dall'Olio, Stefano
    Engelbrecht, Kurt
    Bahl, Christian
    BUILDING SIMULATION, 2018, 11 (04) : 753 - 763
  • [4] Active magnetic regenerators implemented as a magnetocaloric heat pump for residential buildings
    Johra, Hicham
    Filonenko, Konstantin
    Heiselberg, Per
    Veje, Christian T.
    Dall'Olio, Stefano
    Engelbrecht, Kurt
    Bahl, Christian R. H.
    THERMAG VIII - INTERNATIONAL CONFERENCE ON CALORIC COOLING, 2018, : 21 - 26
  • [5] Integration of a magnetocaloric heat pump in a low-energy residential building
    Hicham Johra
    Konstantin Filonenko
    Per Heiselberg
    Christian Veje
    Tian Lei
    Stefano Dall’Olio
    Kurt Engelbrecht
    Christian Bahl
    Building Simulation, 2018, 11 : 753 - 763
  • [6] Magnetocaloric Heat Pump
    朱盛榕
    热能动力工程, 2020, 35 (02) : 9 - 9
  • [7] Heat pump COP, part 2: Generalized COP estimation of heat pump processes
    Jensen, Jonas K.
    Ommen, Torben
    Reinholdt, Lars
    Markussen, Wiebke B.
    Elmegaard, Brian
    13TH IIR GUSTAV LORENTZEN CONFERENCE ON NATURAL REFRIGERANTS: NATURAL REFRIGERANT SOLUTIONS FOR WARM CLIMATE COUNTRIES, 2018, : 1255 - 1264
  • [8] Numerical Simulation of a Magnetocaloric Heat Pump for Domestic Hot Water Production in Residential Buildings
    Johra, Hicham
    Filonenko, Konstantin
    Marszal-Pomianowska, Anna
    Heiselberg, Per
    Veje, Christian
    Dall'Olio, Stefano
    Engelbrecht, Kurt
    Bahl, Christian
    PROCEEDINGS OF BUILDING SIMULATION 2019: 16TH CONFERENCE OF IBPSA, 2020, : 1948 - 1955
  • [9] The design of a seasonal heat storage system with a geothermal heat pump for a residential building in Tehran
    Shamsabadi, Akbar Alidadi
    Jahangiri, Mehdi
    Rezaei, Tayebeh
    Farsani, Rouhollah Yadollahi
    Seryani, Ali
    Hakim, Siavash
    JOURNAL OF ENGINEERING DESIGN AND TECHNOLOGY, 2022, 20 (06) : 1606 - 1626
  • [10] FUNDAMENTAL CHARACTERISTICS OF MAGNETOCALORIC HEAT PUMP
    Hirano, Shigeki
    Kawanami, Tsuyoshi
    Hirasawa, Shigeki
    Fumoto, Koji
    Ikegawa, Masahiro
    PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON POWER ENGINEERING 2009 (ICOPE-09), VOL 3, 2009, : 157 - 161