A Novel Two-Step Method for Converting Lumbar Cortical Screw to Pedicle Screw: A Case Report

被引:0
作者
Muzyka, Logan [1 ]
Shah, Darsh S. [1 ,2 ]
Koltz, Michael T. [1 ]
机构
[1] Univ Texas Austin, Dell Med Sch, Dept Neurosurg, Austin, TX 78712 USA
[2] Univ Texas Med Branch, Dept Neurosurg, Galveston, TX USA
关键词
operative technique; new technologies in neurosurgery; new technology in spine surgery; spine surgery; case report; spine revision; pedicle screw; neuronavigation; cortical bone trajectory; BONE TRAJECTORY SCREW; INTERBODY FUSION; FIXATION;
D O I
10.7759/cureus.61454
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The cortical bone trajectory (CBT) technique has emerged as a minimally invasive approach for lumbar fusion but may result in pseudoarthrosis and hardware failure. This report presents a case of successful pedicle screw revision in a patient with previous failed L2 and L3 fusion using a novel "two-step" technique, including (1) drilling a new trajectory with Medtronic EM800N Stealth MIDAS Navigated MR8 drill system POWEREASETM (Medtronic), described here for the first time. This method involves utilizing neuronavigation and specialized instruments to safely place pedicle screws through the path of the old cortical screw trajectory, addressing the challenges associated with CBT hardware failure.
引用
收藏
页数:7
相关论文
共 20 条
[1]   Fatigue Performance of Cortical Bone Trajectory Screw Compared With Standard Trajectory Pedicle Screw [J].
Akpolat, Yusuf Tahiri ;
Inceoglu, Serkan ;
Kinne, Nolan ;
Hunt, Devon ;
Cheng, Wayne K. .
SPINE, 2016, 41 (06) :E335-E341
[2]   Cortical screws used to rescue failed lumbar pedicle screw construct: a biomechanical analysis [J].
Calvert, Graham C. ;
Lawrence, Brandon D. ;
Abtahi, Amir M. ;
Bachus, Kent N. ;
Brodke, Darrel S. .
JOURNAL OF NEUROSURGERY-SPINE, 2015, 22 (02) :166-172
[3]  
Delgado-Fernandez J, 2017, ASIAN SPINE J, V11, P817, DOI 10.4184/asj.2017.11.5.817
[4]   Comparison of cortical bone trajectory versus pedicle screw techniques in lumbar fusion surgery A meta-analysis [J].
Hu, Jing-Nan ;
Yang, Xiao-Feng ;
Li, Chuan-Ming ;
Li, Xin-Xin ;
Ding, Yun-Zhi .
MEDICINE, 2019, 98 (33)
[5]   Pedicle screw insertion angle and pullout strength: comparison of 2 proposed strategies [J].
Inceoglu, Serkan ;
Montgomery, William H., Jr. ;
St Clair, Selvon ;
McLain, Robert F. .
JOURNAL OF NEUROSURGERY-SPINE, 2011, 14 (05) :670-676
[6]   Short-Term Results of Transforaminal Lumbar Interbody Fusion Using Pedicle Screw with Cortical Bone Trajectory Compared with Conventional Trajectory [J].
Kasukawa, Yuji ;
Miyakoshi, Naohisa ;
Hongo, Michio ;
Ishikawa, Yoshinori ;
Kudo, Daisuke ;
Shimada, Yoichi .
ASIAN SPINE JOURNAL, 2015, 9 (03) :440-448
[7]  
Kaye ID, 2017, JBJS REV, V5, DOI 10.2106/JBJS.RVW.16.00120
[8]   The comparison of pedicle screw and cortical screw in posterior lumbar interbody fusion: a prospective randomized noninferiority trial [J].
Lee, Gun Woo ;
Son, Jung-Hwan ;
Ahn, Myun-Whan ;
Kim, Ho-Joong ;
Yeom, Jin S. .
SPINE JOURNAL, 2015, 15 (07) :1519-1526
[9]   Traditional and cortical trajectory screws of static and dynamic lumbar fixation- a finite element study [J].
Liu, Che-Wei ;
Wang, Lu-Lin ;
Xu, Yu-Kun ;
Chen, Chun-Ming ;
Wang, Jian-Cyuan ;
Tsai, Wei-Tsung ;
Lin, Shang-Chih .
BMC MUSCULOSKELETAL DISORDERS, 2020, 21 (01)
[10]   Postoperative Low Back Pain after Posterior Lumbar Interbody Fusion Surgery Using Cortical Bone Trajectory Screws [J].
Nakajima, Nozumu ;
Maenaka, Takahiro ;
Kano, Hiroki .
ASIAN SPINE JOURNAL, 2020, 14 (05) :655-662