Free-breathing high-resolution respiratory-gated radial stack-of-stars magnetic resonance imaging of the upper abdomen at 7 T

被引:1
作者
Maatman, Ivo T. [1 ,5 ]
Schulz, Jenni [1 ,2 ]
Ypma, Sjoerd [1 ]
Block, Kai Tobias [3 ]
Schmitter, Sebastian [4 ]
Hermans, John J. [1 ]
Smit, Ewoud J. [1 ]
Maas, Marnix C. [1 ]
Scheenen, Tom W. J. [1 ,2 ]
机构
[1] Radboud Univ Nijmegen, Med Ctr, Dept Med Imaging, Nijmegen, Netherlands
[2] Erwin L Hahn Inst MR Imaging, Essen, Germany
[3] NYU Langone Hlth, Dept Radiol, New York, NY USA
[4] Phys Tech Bundesanstalt PTB, Berlin, Germany
[5] Radboud Univ Nijmegen, Med Ctr, Dept Med Imaging 766, Geert Grootepl 10,POB 9101, NL-6500 HB Nijmegen, Netherlands
关键词
radial sampling; respiratory gating; TIAMO; ultrahigh field MRI; LYMPH-NODE METASTASES; ARTIFACT REDUCTION; MRI; RECONSTRUCTION; ANGIOGRAPHY; EXCITATION; CANCER; ARRAY; 1ST; CHALLENGES;
D O I
10.1002/nbm.5180
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Ultrahigh field magnetic resonance imaging (MRI) (>= 7 T) has the potential to provide superior spatial resolution and unique image contrast. Apart from radiofrequency transmit inhomogeneities in the body at this field strength, imaging of the upper abdomen faces additional challenges associated with motion-induced ghosting artifacts. To address these challenges, the goal of this work was to develop a technique for high-resolution free-breathing upper abdominal MRI at 7 T with a large field of view. Free-breathing 3D gradient-recalled echo (GRE) water-excited radial stack-of-stars data were acquired in seven healthy volunteers (five males/two females, body mass index: 19.6-24.8 kg/m2) at 7 T using an eight-channel transceive array coil. Two volunteers were also examined at 3 T. In each volunteer, the liver and kidney regions were scanned in two separate acquisitions. To homogenize signal excitation, the time-interleaved acquisition of modes (TIAMO) method was used with personalized pairs of B1 shims, based on a 23-s Cartesian fast low angle shot (FLASH) acquisition. Utilizing free-induction decay navigator signals, respiratory-gated images were reconstructed at a spatial resolution of 0.8 x 0.8 x 1.0 mm3. Two experienced radiologists rated the image quality and the impact of B1 inhomogeneity and motion-related artifacts on multipoint scales. The images of all volunteers showcased effective water excitation and were accurately corrected for respiratory motion. The impact of B1 inhomogeneity on image quality was minimal, underscoring the efficacy of the multitransmit TIAMO shim. The high spatial resolution allowed excellent depiction of small structures such as the adrenal glands, the proximal ureter, the diaphragm, and small blood vessels, although some streaking artifacts persisted in liver image data. In direct comparisons with 3 T performed for two volunteers, 7-T acquisitions demonstrated increases in signal-to-noise ratio of 77% and 58%. Overall, this work demonstrates the feasibility of free-breathing MRI in the upper abdomen at submillimeter spatial resolution at a magnetic field strength of 7 T. Ultrahigh field MRI provides exceptional resolution and unique image contrast but encounters difficulties in abdominal imaging due to respiratory motion and signal inhomogeneities in larger regions of interest. This study introduces techniques for high-resolution, free-breathing 7-T abdominal MRI, resulting in excellent image quality as evaluated by radiologists. image
引用
收藏
页数:16
相关论文
共 87 条
[61]   Vessel wall imaging in intracranial aneurysms [J].
Samaniego, Edgar A. ;
Roa, Jorge A. ;
Hasan, David .
JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2019, 11 (11) :1105-+
[62]   The Role of Magnetic Resonance Imaging in (Future) Cancer Staging Note the Nodes [J].
Scheenen, Tom W. J. ;
Zamecnik, Patrik .
INVESTIGATIVE RADIOLOGY, 2021, 56 (01) :42-49
[63]   The role of magnetic susceptibility in magnetic resonance imaging: MRI magnetic compatibility of the first and second kinds [J].
Schenck, JF .
MEDICAL PHYSICS, 1996, 23 (06) :815-850
[64]   Design of parallel transmission radiofrequency pulses robust against respiration in cardiac MRI at 7 Tesla [J].
Schmitter, Sebastian ;
Wu, Xiaoping ;
Ugurbil, Kamil ;
Van de Moortele, Pierre-Francois .
MAGNETIC RESONANCE IN MEDICINE, 2015, 74 (05) :1291-1305
[65]   Seven-Tesla Time-of-Flight Angiography Using a 16-Channel Parallel Transmit System With Power-Constrained 3-dimensional Spoke Radiofrequency Pulse Design [J].
Schmitter, Sebastian ;
Wu, Xiaoping ;
Auerbach, Edward J. ;
Adriany, Gregor ;
Pfeuffer, Josef ;
Hamm, Michael ;
Ugurbil, Kamil ;
van de Moortele, Pierre-Francois .
INVESTIGATIVE RADIOLOGY, 2014, 49 (05) :314-325
[66]   Small hyperintense hepatic lesions on T1-weighted images in patients with cirrhosis: evaluation with serial MRI and imaging features for clinical benignity [J].
Shimizu, Ayame ;
Ito, Katsuyoshi ;
Sasaki, Katsumi ;
Hayashida, Minoru ;
Tanabe, Masahiro ;
Shimizu, Kensaku ;
Matsunaga, Naofumi .
MAGNETIC RESONANCE IMAGING, 2007, 25 (10) :1430-1436
[67]   Gadolinium-Induced Fibrosis [J].
Todd, Derrick J. ;
Kay, Jonathan .
ANNUAL REVIEW OF MEDICINE, VOL 67, 2016, 67 :273-291
[68]   B1 Artifact Reduction in Abdominal DCE-MRI Using kT-Points: First Clinical Assessment of Dynamic RF Shimming at 3T [J].
Tomi-Tricot, Raphael ;
Gras, Vincent ;
Mauconduit, Franck ;
Legou, Francois ;
Boulant, Nicolas ;
Gebhardt, Matthias ;
Ritter, Dieter ;
Kiefer, Berthold ;
Zerbib, Pierre ;
Rahmouni, Alain ;
Vignaud, Alexandre ;
Luciani, Alain ;
Amadon, Alexis .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2018, 47 (06) :1562-1571
[69]   Imaging at ultrahigh magnetic fields: History, challenges, and solutions [J].
Ugurbil, Kamil .
NEUROIMAGE, 2018, 168 :7-32
[70]   7 Tesla MPRAGE Imaging of the Intracranial Arterial Vasculature: Nonenhanced versus Contrast-Enhanced [J].
Umutlu, Lale ;
Theysohn, Nina ;
Maderwald, Stefan ;
Johst, Soeren ;
Lauenstein, Thomas C. ;
Moenninghoff, Christoph ;
Goericke, Sophia L. ;
Dammann, Philipp ;
Wrede, Karsten H. ;
Ladd, Mark E. ;
Forsting, Michael ;
Schlamann, Marc .
ACADEMIC RADIOLOGY, 2013, 20 (05) :628-634