Axial Compression Performance of L-Shaped Partially Encased Steel-Concrete Composite Stub Columns

被引:1
作者
Qi, Yuansen [1 ,2 ]
Zhu, Haochuan [2 ,3 ]
Xu, Youwu [4 ]
Xiao, Zhibin [2 ,3 ]
Jin, Zhenfen [2 ,3 ]
机构
[1] Zhejiang Univ, Coll Civil Engn & Architecture, Hangzhou 310058, Peoples R China
[2] Zhejiang Univ, Ctr Balance Architecture, Hangzhou 310058, Peoples R China
[3] Architecture Design & Res Inst Zhejiang Univ Co Lt, Hangzhou 310058, Peoples R China
[4] Zhejiang Coll Construct, Dept Construct Engn, Hangzhou 311231, Peoples R China
关键词
L-shaped; partially encased steel-concrete composite stub column; axial compression capacity; concrete confinement effect; BEHAVIOR; STRENGTH;
D O I
10.3390/buildings14093001
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The L-shaped partially encased steel-concrete composite (PEC) stub column, composed of profile steel, concrete, and transverse links, tends to occupy less space than the rectangle-shaped PEC column when used as side or corner columns. In this study, an axial compression test involving three L-shaped PEC stub columns was conducted to investigate the influence of critical factors on axial compression performance. The test results indicated that the axial compression capacity can be effectively enhanced with an increase in material strength. Furthermore, finite element (FE) analysis was carried out with parameters such as material strength, steel thickness, transverse link spacing, transverse link diameter, transverse link distribution, and longitudinal rebar diameter. The results revealed that the primary failure modes of L-shaped PEC columns were concrete spalling and local buckling of the flange. Additionally, it was found that the increase in steel strength, steel thickness, and transverse link diameter, as well as the decrease in transverse link spacing, significantly improved the axial compression capacity and concrete confinement effect. However, an increase in concrete strength diminished the concrete confinement effect. Additionally, the accuracy of the axial compression capacity calculation methods in the Eurocode 4 and T/CECS719-2010 specifications for L-shaped PEC stub columns was verified. Finally, a calculation method based on the superposition principle incorporating the concrete confinement effect was proposed, and validated by comparing with experimental and FE results. Overall, this study could provide a theoretical basis for the engineering application of L-shaped PEC columns.
引用
收藏
页数:27
相关论文
共 41 条
[1]  
[Anonymous], 2019, GB/T50081-2019
[2]  
[Anonymous], 2020, T/CECS 719-2020
[3]  
[Anonymous], 2021, Metallic Materials-Tensile Testing-Part1: Method of Test at Room Temperature
[4]  
[Anonymous], 2015, GB 50010-2010
[5]  
Begum M., 2007, Struct. Eng. Rep, P1
[6]   Finite-element modeling of partially encased composite columns using the dynamic explicit method [J].
Begum, Mahbuba ;
Driver, Robert G. ;
Elwi, Alaa E. .
JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 2007, 133 (03) :326-334
[7]   Behaviour of partially encased composite columns with high strength concrete [J].
Begum, Mahbuba ;
Driver, Robert G. ;
Elwi, Alaa E. .
ENGINEERING STRUCTURES, 2013, 56 :1718-1727
[8]   Similarity analysis of the fire-resistant behaviour of partially encased composite columns in different scales [J].
Cai, Xinjiang ;
Xu, Chao ;
Zhu, Yong ;
Shi, Hanyuan ;
Mao, Xiaoyong ;
Tian, Shizhu .
STRUCTURES, 2024, 62
[9]  
CEN, 2004, EN1994-1-1:2004
[10]   Analytical model for predicting axial capacity and behavior of concrete encased steel composite stub columns [J].
Chen, CC ;
Lin, NJ .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2006, 62 (05) :424-433