Characterizing devices for validation of dose, dose rate, and LET in ultra high dose rate proton irradiations

被引:1
|
作者
Harrison, Nathan [1 ]
Charyyev, Serdar [2 ]
Oancea, Cristina [3 ]
Stanforth, Alexander [4 ]
Gelover, Edgar [1 ]
Zhou, Shuang [5 ]
Dynan, William S. [1 ]
Zhang, Tiezhi [5 ]
Biegalski, Steven [4 ]
Lin, Liyong [1 ]
机构
[1] Emory Univ, Atlanta, GA 30322 USA
[2] Stanford Univ, Stanford, CA USA
[3] ADVACAM sro, Prague, Czech Republic
[4] Georgia Inst Technol, Atlanta, GA USA
[5] Washington Univ St Louis, St Louis, MO USA
关键词
3D printing; FLASH proton therapy; linear energy transfer (LET); ridge filter; Timepix3; IONIZATION-CHAMBER ARRAY; LINEAR-ENERGY-TRANSFER; THERAPY; DELIVERY; MODEL; RAYS;
D O I
10.1002/mp.17359
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Ultra high dose rate (UHDR) radiotherapy using ridge filter is a new treatment modality known as conformal FLASH that, when optimized for dose, dose rate (DR), and linear energy transfer (LET), has the potential to reduce damage to healthy tissue without sacrificing tumor killing efficacy via the FLASH effect. Purpose: Clinical implementation of conformal FLASH proton therapy has been limited by quality assurance (QA) challenges, which include direct measurement of UHDR and LET. Voxel DR distributions and LET spectra at planning target margins are paramount to the DR/LET-related sparing of organs at risk. We hereby present a methodology to achieve experimental validation of these parameters. Methods: Dose, DR, and LET were measured for a conformal FLASH treatment plan involving a 250-MeV proton beam and a 3D-printed ridge filter designed to uniformly irradiate a spherical target. We measured dose and DR simultaneously using a 4D multi-layer strip ionization chamber (MLSIC) under UHDR conditions. Additionally, we developed an "under-sample and recover (USRe)" technique for a high-resolution pixelated semiconductor detector, Timepix3, to avoid event pile-up and to correct measured LET at high-proton-flux locations without undesirable beam modifications. Confirmation of these measurements was done using a MatriXX PT detector and by Monte Carlo (MC) simulations. Results: MC conformal FLASH computed doses had gamma passing rates of >95% (3 mm/3% criteria) when compared to MatriXX PT and MLSIC data. At the lateral margin, DR showed average agreement values within 0.3% of simulation at 100 Gy/s and fluctuations similar to 10% at 15 Gy/s. LET spectra in the proximal, lateral, and distal margins had Bhattacharyya distances of <1.3%. Conclusion: Our measurements with the MLSIC and Timepix3 detectors shown that the DR distributions for UHDR scenarios and LET spectra using USRe are in agreement with simulations. These results demonstrate that the methodology presented here can be used effectively for the experimental validation and QA of FLASH treatment plans.
引用
收藏
页码:8411 / 8422
页数:12
相关论文
共 50 条
  • [1] Proton Irradiations at Ultra-High Dose Rate vs. Conventional Dose Rate: Strong Impact on Hydrogen Peroxide Yield
    Blain, Guillaume
    Vandenborre, Johan
    Villoing, Daphnee
    Fiegel, Vincent
    Fois, Giovanna Rosa
    Haddad, Ferid
    Koumeir, Charbel
    Maigne, Lydia
    Metivier, Vincent
    Poirier, Freddy
    Potiron, Vincent
    Supiot, Stephane
    Servagent, Noel
    Delpon, Gregory
    Chiavassa, Sophie
    RADIATION RESEARCH, 2022, 198 (03) : 318 - 324
  • [2] Validation of a Novel Device for Characterizing Ultra High Dose Rate (FLASH) Electron Beams
    Jain, S.
    Woollard, J.
    Cetnar, A.
    Gupta, N.
    Ayan, A.
    MEDICAL PHYSICS, 2022, 49 (06) : E129 - E129
  • [3] An Effective Dose Rate Optimization Algorithm for Efficient Conventional-Dose-Rate Proton Therapy and Ultra-High Dose-Rate FLASH Proton Therapy
    Zhu, Y. N.
    Zhang, X.
    Lin, Y.
    Lominska, C.
    Gao, H.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2023, 117 (02): : S37 - S38
  • [4] THE DESIGN AND DEVELOPMENT OF A TARGET CHAMBER FOR HIGH-DOSE RATE PROTON IRRADIATIONS
    CAWLEY, J
    EARWAKER, LG
    PHYTHIAN, WJ
    JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1989, 22 (06): : 372 - 377
  • [5] In situ correction of recombination effects in ultra-high dose rate irradiations with protons
    Schaefer, R.
    Psoroulas, S.
    Weber, D. C.
    PHYSICS IN MEDICINE AND BIOLOGY, 2023, 68 (10):
  • [6] Biological equivalence of low dose rate to multifractionated high dose rate irradiations: Investigations in mouse lip mucosa
    Stuben, G
    vanderKogel, AJ
    vanderSchueren, E
    RADIOTHERAPY AND ONCOLOGY, 1997, 42 (02) : 189 - 196
  • [7] The Impact of Ultra-High-Dose Rate (FLASH) Proton Therapy On Radiation Dose to Circulating Lymphocytes
    Hammi, A.
    MEDICAL PHYSICS, 2022, 49 (06) : E569 - E569
  • [8] Effect of high dose rate irradiations on COTS optical fibres
    Girard, S
    Baggio, J
    Martinez, M
    17th International Conference on Optical Fibre Sensors, Pts 1 and 2, 2005, 5855 : 519 - 522
  • [9] Dose and dose rate dependence of the tissue sparing effect at ultra-high dose rate studied for proton and electron beams using the zebrafish embryo model
    Horst, Felix
    Bodenstein, Elisabeth
    Brand, Michael
    Hans, Stefan
    Karsch, Leonhard
    Lessmann, Elisabeth
    Loeck, Steffen
    Schuerer, Michael
    Pawelke, Joerg
    Beyreuther, Elke
    RADIOTHERAPY AND ONCOLOGY, 2024, 194
  • [10] Comparison of Ion Chamber Recombination in High and Low LET Regions for Ultra-High Dose Rate Proton Radiation
    Curtis, N.
    Motlagh, S. A. Oliaei
    Zou, J.
    Wiersma, R. D.
    Diffenderfer, E. S.
    Kim, M. M.
    MEDICAL PHYSICS, 2024, 51 (10) : 7928 - 7928